The 330180-X2-00 (MOD 181634-02) is a high-precision eddy current proximity transducer system designed for continuous non-contact measurement of shaft vibration, displacement, and rotor position in rotating machinery.
It is commonly used in industrial machinery protection systems where accurate real-time monitoring of mechanical movement is required to ensure operational safety and equipment stability.
The system works by detecting variations in an electromagnetic field generated between the probe and a conductive target surface, converting displacement into a calibrated analog voltage signal.
(Company name intentionally omitted as requested)
This series is widely recognized for high accuracy, long-term stability, and robust performance in heavy industrial monitoring environments.
The 330180-X2-00 (MOD 181634-02) is widely used in the following industrial sectors:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog linear voltage |
| Measurement principle | Eddy current induction |
| Output impedance | 50–100 Ω |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 5 mm (typical linear range) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response within calibrated range |
| Repeatability | Excellent under stable operating conditions |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +121°C |
| Storage temperature | -55°C to +125°C |
| Humidity range | 5% – 95% non-condensing |
| Vibration resistance | Up to 20 g depending on installation |
| EMI protection | High industrial electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Signal conditioner dimensions | 100 mm × 160 mm × 50 mm |
| Probe material | Stainless steel housing |
| Cable type | Shielded coaxial cable |
| Cable length options | 3 m / 5 m / 9 m |
| Total system weight | ~2.0 kg |
| Probe weight | ~0.08 kg |
| Mounting type | Panel / rack installation |
The system operates using eddy current electromagnetic induction:
This allows accurate, non-contact measurement of micrometer-level displacement in rotating machinery.
| Parameter | 330180-X2-00 181634-02 | 330180-X1-05 | 330180-X2-00 181634-11 | 330180-X2-00 181634-19 | 330180-X2-00 181634-27 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–5 mm | 0–2 mm | 0–5 mm | 0–5 mm | 0–5 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm |
| Weight (kg) | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg |
| Parameter | 330780-97-00 | 330881-28-16-150-02-02 | 330103-00-12-10-02-00 | 330106-05-65-10-02-00 | 330104-00-12-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 110×170×55 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 1.6 kg | 2.3 kg | 1.2 kg | 1.2 kg | 1.2 kg |
| Parameter | 330901-00-19-10-02-05 | 330905-00-18-10-02-00 | 330909-00-55-10-02-05 | 330910-00-18-10-02-00 | 330930-00-11-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 95×150×45 mm | 120×180×60 mm | 100×160×50 mm | 95×150×45 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330180-X2-00 (MOD 181634-02) is a reliable eddy current proximity transducer system designed for continuous monitoring of rotating machinery. It offers stable accuracy, strong environmental resistance, and long-term operational reliability in demanding industrial conditions.
Its modular design and compatibility with industrial monitoring systems make it widely applicable in power generation, petrochemical, and heavy industrial environments.