The 330180-X1-RU (MOD 145655-23) is a high-precision eddy current proximity transducer system designed for continuous, non-contact monitoring of shaft vibration, axial displacement, and rotor position in rotating machinery.
It is used in industrial machinery protection systems where stable and accurate real-time measurement is required to ensure safe operation of high-speed rotating equipment.
The system converts the distance variation between the probe and a conductive metallic surface into a proportional electrical signal, enabling precise mechanical condition monitoring.
(Company name intentionally omitted as requested)
This series is widely used in industrial monitoring applications due to its stability, durability, and high measurement accuracy.
The 330180-X1-RU (MOD 145655-23) is applied in a wide range of industrial environments, including:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog linear voltage |
| Measurement principle | Eddy current induction |
| Output impedance | 50–100 Ω |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 5 mm (typical linear range) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response within calibrated range |
| Repeatability | Excellent stability under continuous operation |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +121°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Up to 20 g depending on installation |
| EMI protection | High industrial electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Signal conditioner dimensions | 100 mm × 160 mm × 50 mm |
| Probe material | Stainless steel housing |
| Cable type | Shielded coaxial cable |
| Cable length options | 3 m / 5 m / 9 m |
| Total system weight | ~2.0 kg |
| Probe weight | ~0.08 kg |
| Mounting type | Panel / rack installation |
The system is based on eddy current electromagnetic induction:
This enables high-precision, non-contact displacement measurement at micrometer level.
| Parameter | 330180-X1-RU 145655-23 | 330180-X1-05 | 330180-X1-RU 143416-77 | 330180-X1-RU 145655-31 | 330180-X1-RU 145655-44 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–5 mm | 0–2 mm | 0–5 mm | 0–5 mm | 0–5 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm |
| Weight (kg) | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg |
| Parameter | 330780-96-00 | 330881-28-15-140-02-02 | 330103-00-11-10-02-00 | 330106-05-60-10-02-00 | 330104-00-11-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 110×170×55 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 1.6 kg | 2.3 kg | 1.2 kg | 1.2 kg | 1.2 kg |
| Parameter | 330901-00-18-10-02-05 | 330905-00-17-10-02-00 | 330909-00-50-10-02-05 | 330910-00-17-10-02-00 | 330930-00-10-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 95×150×45 mm | 120×180×60 mm | 100×160×50 mm | 95×150×45 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330180-X1-RU (MOD 145655-23) is a high-performance eddy current proximity transducer system designed for continuous monitoring of rotating machinery. It delivers stable accuracy, strong environmental resistance, and long-term operational reliability in demanding industrial environments.
Its modular architecture and compatibility with industrial control systems make it suitable for power generation, petrochemical, and heavy industry applications.