• Schneider TSXSCPCM4030 Modbus Connection Cable
  • Schneider TSXSCPCM4030 Modbus Connection Cable
  • Schneider TSXSCPCM4030 Modbus Connection Cable
  • Schneider TSXSCPCM4030 Modbus Connection Cable
Product Overview The Schneider Electric TSXSCPCM4030 Modbus Connection Cable is an industrial communication accessory designed for the Modicon Premium automation platform. It provides a physical connect……
Schneider TSXSCPCM4030 Modbus Connection Cable
  • Schneider
  • TSXSCPCM4030
  • Modbus Connection Cable
  • France
  • 3 meters
  • 0.16 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 12

Our advantage

Schneider TSXSCPCM4030 Modbus Connection Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TSXSCPCM4030 Modbus Connection Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TSXSCPCM4030 Modbus Connection Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TSXSCPCM4030 Modbus Connection Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric TSXSCPCM4030 Modbus Connection Cable is an industrial communication accessory designed for the Modicon Premium automation platform. It provides a physical connection between compatible communication hardware and a passive junction box, supporting serial data communication through an isolated RS422/RS485 tap link.

With a cable length of 3 meters, the TSXSCPCM4030 offers a practical connection distance for installations where a Modicon Premium communication card needs to be linked to an external connection point. Its flying-lead termination allows the cable conductors to be connected to the appropriate terminals in the communication installation.

The cable is designed for Modbus communication in character mode and is associated with the TSXSCP114 communication card and TSXSCA50 connection equipment. It is intended for industrial automation systems in which reliable serial communication is required between controllers and connected devices.

Unlike a PLC CPU or communication module, the TSXSCPCM4030 does not perform data processing or protocol conversion independently. Its role is to provide the physical communication connection required by the associated hardware. Correct wiring, terminal assignment, shielding, and grounding are therefore essential to achieving stable communication.

This cable is particularly relevant to maintenance and replacement work involving existing Modicon Premium installations. Since the product has been discontinued, confirming the complete reference number and connector arrangement is important before purchasing a replacement.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Model TSXSCPCM4030
Product Type Modbus Connection Cable
Product Range Modicon Premium Automation Platform
Cable Function Isolated RS422/RS485 Tap Link
Communication Protocol Modbus
Communication Mode Character Mode
Cable Length 3 meters
Electrical Connection Flying Leads
Connection Destination Passive Junction Box
Compatible Equipment TSXSCP114, TSXSCA50
Communication Interface RS422/RS485
Net Weight 0.16 kg
Physical Cable Dimensions Not specified in the supplied product data
Product Lifecycle Discontinued

Function and Working Principle

The TSXSCPCM4030 provides the physical connection required for serial communication between compatible Modicon Premium communication equipment and an external connection point.

Its operation depends on the communication hardware, wiring arrangement, and Modbus configuration used in the automation system.

1. Physical Serial Communication Connection

The cable connects the compatible communication interface to the designated passive junction equipment. Its 3-meter length allows the connected devices to be positioned within a suitable installation distance.

The cable does not generate communication signals independently. Instead, it carries the electrical signals produced by the connected communication hardware.

Correct terminal identification is necessary to maintain the intended signal paths.

2. RS422/RS485 Communication Support

The TSXSCPCM4030 is specified for an isolated RS422/RS485 tap-link application. These serial communication standards are widely used in industrial environments because they support differential signaling.

Differential communication uses signal pairs to help distinguish the transmitted data from electrical interference affecting both conductors. This characteristic is useful in industrial installations where motors, drives, contactors, and switching equipment may generate electrical noise.

The exact wiring arrangement must follow the connected communication equipment’s documentation.

3. Modbus Communication

The cable supports Modbus communication in character mode.

Modbus is commonly used to exchange information between industrial controllers, instruments, and other automation devices. Depending on the system configuration, exchanged information may include equipment status, process values, operating commands, and diagnostic information.

The cable provides the physical connection but does not determine the communication address, baud rate, parity, or other protocol parameters. These settings must be configured in the connected devices.

4. Flying-Lead Termination

The TSXSCPCM4030 uses flying leads rather than a pre-installed standard connector at the cable end.

This arrangement allows the conductors to be connected to the appropriate terminals inside the designated connection equipment.

Before installation, technicians should identify each conductor and confirm its function using the manufacturer’s wiring documentation. Incorrect signal connections may prevent communication or cause intermittent data errors.

5. Connection to Passive Junction Equipment

The cable is designed for connection to a passive junction box. The junction equipment provides the required physical connection arrangement for the serial communication network.

The TSXSCA50 is one of the compatible devices identified for this cable. The complete communication topology must follow the applicable Modicon Premium installation instructions.

Role in Industrial Control Systems

The TSXSCPCM4030 plays a supporting role in industrial communication infrastructure. It provides the physical link between compatible communication hardware and the serial network connection point.

Modicon Premium PLC Communication

In a Modicon Premium control system, communication hardware allows the PLC to exchange information with external devices.

The TSXSCPCM4030 supports the physical connection associated with the TSXSCP114 communication card. This makes it relevant to installations that use Modbus communication through the Premium platform.

The cable itself does not replace the communication card or PLC controller. It operates as an accessory within the complete communication arrangement.

Communication Between Industrial Devices

Industrial systems frequently contain multiple devices that need to exchange information. These may include controllers, instruments, motor-control equipment, and other automation components.

A properly installed serial communication cable helps establish the physical connection required for data exchange.

The actual communication capability depends on the connected equipment, supported protocol, network configuration, and wiring design.

Maintenance of Existing Automation Networks

In an established industrial installation, communication cables may experience insulation deterioration, mechanical damage, loose terminals, or connection problems.

Replacing a damaged cable with the correct model can help restore the original communication arrangement without requiring unnecessary changes to the controller architecture.

For legacy systems, maintaining the original cable reference and wiring configuration can simplify troubleshooting and replacement work.

Industrial Applications

The TSXSCPCM4030 is intended for serial communication installations using compatible Modicon Premium equipment.

1. Modicon Premium PLC Systems

The cable can be used in Modicon Premium automation systems where the TSXSCP114 communication card and TSXSCA50 connection equipment are installed.

It provides the physical link needed for the associated Modbus communication arrangement.

2. Industrial Modbus Networks

Modbus communication is used in many industrial applications to exchange information between controllers and connected equipment.

The TSXSCPCM4030 supports the physical communication connection in compatible RS422/RS485 tap-link installations.

3. Manufacturing Automation

Manufacturing facilities often use serial communication to connect controllers with instruments and other automation devices.

The cable may be used in legacy Modicon Premium installations where communication connections must be maintained during equipment servicing or replacement.

4. Process Control Systems

Process-control installations may use Modbus communication to exchange operating information between controllers and field equipment.

The TSXSCPCM4030 can serve as a connection accessory in compatible serial communication arrangements. The suitability of the cable depends on the communication hardware and network design.

5. Industrial Equipment Maintenance

During maintenance, communication cables may need replacement because of damaged conductors, loose connections, or deteriorated insulation.

Using the correct cable reference helps preserve the original connection arrangement and reduces the possibility of wiring modifications.

Installation and System Integration

Correct installation is essential for reliable communication and long-term cable performance.

1. Verify Equipment Compatibility

Before installation, confirm that the connected equipment is compatible with the TSXSCPCM4030.

The documented compatible equipment includes:

  • TSXSCP114 communication card.
  • TSXSCA50 connection equipment.

Do not assume that every Modbus or RS485 device can use this cable directly. Connector arrangements and electrical interfaces must be checked.

2. Confirm the Cable Length

The TSXSCPCM4030 has a cable length of 3 meters.

Before installation, measure the required cable route and confirm that the available length is sufficient. Avoid unnecessary tension, sharp bends, or routing that could expose the cable to mechanical damage.

3. Identify the Flying Leads

The cable uses flying-lead termination. Each conductor must be identified according to the applicable wiring diagram.

Do not determine signal assignments from conductor color alone unless the manufacturer’s documentation confirms the color coding.

Incorrect wiring may result in communication failure, unstable data exchange, or equipment faults.

4. Follow RS422/RS485 Wiring Requirements

Serial communication wiring should follow the requirements of the connected communication hardware.

Pay attention to signal polarity, common references, shielding, and grounding. Where the installation requires termination or biasing arrangements, follow the communication equipment’s instructions.

Avoid making arbitrary changes to the network topology.

5. Separate Communication and Power Wiring

Where practical, route communication cables separately from high-voltage power cables and motor conductors.

Variable frequency drives, contactors, and other switching equipment can generate electromagnetic interference. Appropriate cable routing and grounding practices help reduce the risk of communication disturbances.

6. Configure Modbus Parameters

The communication settings must be configured in the connected equipment.

Typical parameters include:

  • Modbus station address.
  • Baud rate.
  • Parity.
  • Data bits.
  • Stop bits.
  • Communication mode.

The settings must match across the communicating devices. The TSXSCPCM4030 does not configure these parameters automatically.

7. Test Communication After Installation

After completing the wiring, inspect the connections and confirm that the communication equipment is correctly installed.

Test data exchange between the connected devices and check for communication errors, intermittent connections, or unexpected timeouts.

Document the final wiring and communication settings for future maintenance.

Compatible System Components

The TSXSCPCM4030 operates as part of a larger Modicon Premium communication arrangement.

Component Function Integration Considerations
TSXSCP114 Modbus RS485 communication card One of the documented compatible devices
TSXSCA50 Passive connection equipment Provides the connection point for the cable
Modicon Premium PLC Executes industrial control logic Uses the configured communication hardware
RS422/RS485-compatible equipment Exchanges serial communication signals Verify electrical interface and wiring
Modbus-compatible devices Exchange data using the Modbus protocol Communication parameters must match
Industrial terminal blocks Provide conductor termination Confirm terminal assignments
Grounding and shielding accessories Support electrical noise management Follow the installation requirements
Industrial control cabinet Houses communication and control equipment Protect connections from environmental and mechanical damage

The components listed above are examples of equipment associated with a compatible installation. They are not necessarily supplied with the TSXSCPCM4030 cable.

Alternative Models and Replacement Considerations

The TSXSCPCM4030 has been discontinued and has no direct replacement listed in the manufacturer’s product information.

When sourcing an alternative, it is important to compare the electrical interface, cable termination, intended connection destination, and compatible communication hardware.

Alternative or Related Model Description Replacement Considerations
TSXSCPCM4030 Original 3-meter Modbus connection cable Exact reference for like-for-like replacement
TSXSCPCM4530 Related RS485 communication cable Different connector arrangement; verify application
TSXSCPCX4030 Related isolated RS422/RS485 tap-link cable Check intended connection destination and system compatibility
TSXSCPCD1030 RS232 communication cable Different communication interface; not a direct substitute
TSXSCPCD1100 10-meter RS232 communication cable Different interface and cable length
TSXSCPCU4030 Uni-Telway communication cable Different communication protocol; not a direct Modbus replacement

A replacement cable should be evaluated according to:

  • Communication interface and electrical characteristics.
  • Supported Modbus communication arrangement.
  • Cable length.
  • Flying-lead or connector termination.
  • Compatible communication card.
  • Compatible junction equipment.
  • Signal conductor identification.
  • Shielding and grounding requirements.

A cable with the same length or a similar appearance may not provide the correct electrical connection.

Key Advantages

Designed for Modicon Premium Equipment

The TSXSCPCM4030 is designed for the Modicon Premium automation platform and is compatible with specified communication accessories.

Modbus Communication Support

It supports Modbus communication in character mode, making it suitable for compatible industrial serial communication installations.

RS422/RS485 Tap-Link Connection

Its specified isolated RS422/RS485 tap-link function supports the communication arrangement used by compatible equipment.

Practical 3-Meter Cable Length

The 3-meter length provides flexibility for connecting communication hardware to a nearby junction point inside an industrial installation.

Flexible Flying-Lead Termination

The flying-lead design allows the conductors to be connected to the designated terminals without requiring a fixed connector at the cable end.

Lightweight Construction

With a net weight of 0.16 kg, the cable is a lightweight accessory that can be handled and installed conveniently.

Useful for Legacy System Maintenance

The cable is relevant to maintenance projects involving existing Modicon Premium installations where the original serial communication architecture needs to be preserved.

Technical FAQs

1. What is the Schneider TSXSCPCM4030?

The TSXSCPCM4030 is a 3-meter Modbus connection cable designed for an isolated RS422/RS485 tap-link application within the Modicon Premium automation platform.

2. What is the cable length?

The cable length is 3 meters, providing a physical connection between compatible communication hardware and the designated junction equipment.

3. Which communication protocol does it support?

The cable is specified for Modbus communication in character mode.

4. Which devices are compatible with the TSXSCPCM4030?

The documented compatible equipment includes the TSXSCP114 communication card and TSXSCA50 passive connection equipment.

5. What type of electrical connection does it use?

The TSXSCPCM4030 uses flying leads. The conductors must be connected to the appropriate terminals according to the manufacturer’s wiring documentation.

6. Is this cable suitable for RS485 communication?

Yes. It is specified for an isolated RS422/RS485 tap-link application. The exact wiring and communication arrangement must match the connected equipment.

7. Does the cable perform Modbus protocol conversion?

No. It provides the physical communication connection. Modbus communication processing is handled by the connected controller and communication devices.

8. Can it be used with any Modbus device?

No. Compatibility depends on the communication interface, wiring arrangement, and connector requirements. The manufacturer identifies TSXSCP114 and TSXSCA50 as compatible equipment.

9. Is the TSXSCPCM4030 still available as a current product?

The model has been discontinued by Schneider Electric. It may still be available through industrial spare-parts suppliers or existing inventory. Confirm its condition and authenticity before purchasing.

10. What should be checked when replacing this cable?

Verify the complete model number, cable length, flying-lead termination, communication interface, conductor assignment, and compatibility with the existing communication card and junction equipment.

Procurement and Maintenance Recommendations

When purchasing the Schneider TSXSCPCM4030, verify the complete product reference and confirm that it matches the cable installed in the existing automation system.

Since the model has been discontinued, procurement may involve unused original stock, surplus inventory, or refurbished industrial spare-parts channels. Buyers should request clear product photographs and confirm the cable’s condition, conductor integrity, and original labeling.

For maintenance projects, inspect the cable insulation, conductor terminations, and connection points regularly. Look for cuts, crushing, excessive bending, loose terminals, and signs of environmental deterioration.

When installing a replacement, preserve the original wiring arrangement wherever possible. Record conductor assignments and communication parameters before disconnecting the old cable. This can simplify commissioning and reduce unnecessary troubleshooting.

If an alternative cable is being considered, compare the communication interface and termination arrangement carefully. A similar-looking cable may have a different purpose or may be designed for another communication protocol.

Conclusion

The Schneider Electric TSXSCPCM4030 Modbus Connection Cable is a 3-meter communication accessory designed for isolated RS422/RS485 tap-link applications within the Modicon Premium automation platform. It supports Modbus communication in character mode and uses flying-lead termination for connection to compatible equipment.

With documented compatibility for the TSXSCP114 communication card and TSXSCA50 connection equipment, the TSXSCPCM4030 is an important spare part for maintaining certain legacy Modicon Premium communication installations.

For replacement and procurement projects, checking the complete model number, cable termination, communication interface, and connected equipment is essential to maintaining reliable industrial data communication.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501