The Schneider Electric TSXPSY5500M Power Supply Module is a power supply component designed for the Modicon Premium Automation Platform. It provides the electrical power required by a PLC rack and its associated control components, supporting stable operation of industrial automation systems.
In a PLC installation, the power supply module is responsible for converting incoming AC power into the DC voltages required by the controller and related modules. These power rails support the operation of the processor, communication interfaces, I/O modules, and other rack-mounted components. Reliable power distribution is essential because unstable voltage or insufficient power capacity can affect controller operation and production continuity.
The TSXPSY5500M accepts a broad range of AC input voltages. It supports 100–120 V AC and 200–240 V AC supplies, making it suitable for installations using different industrial AC power standards within its specified operating limits.
The module provides a total useful secondary power of 50 W. Its documented outputs include 35 W at 5 V DC and 19 W at 24 V DC. The 5 V DC output supplies the PLC rack, while the 24 V DC outputs support relay and sensor power requirements. The module also includes protection against secondary-side overload, overvoltage, and short circuits.
As part of the Modicon Premium platform, the TSXPSY5500M is intended for use with compatible Premium PLC racks. It should not be treated as a universal standalone power supply. Rack compatibility, power requirements, mounting arrangements, and wiring must be checked before installation.
The model has been discontinued and is now associated with service and spare-parts requirements. It remains relevant to facilities maintaining existing Modicon Premium systems, particularly where replacing the original power supply with a compatible unit is necessary to preserve the existing automation architecture.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Model | TSXPSY5500M |
| Product Type | Power Supply Module |
| Product Family | Modicon Premium |
| Module Format | Double |
| Primary Input Voltage | 100–120 V AC / 200–240 V AC |
| Input Voltage Range | 85–140 V AC / 190–264 V AC |
| Input Frequency | 50/60 Hz |
| Frequency Limits | 47–63 Hz |
| Input Current | 1.7 A at 100 V / 0.5 A at 240 V |
| Inrush Current | 38 A |
| Total Useful Secondary Power | 50 W |
| 5 V DC Secondary Power | 35 W |
| 5 V DC Output Current | 7 A |
| 24 V DC Secondary Power | 19 W |
| 24 V DC Relay Supply Current | 0.8 A |
| 24 V DC Sensor Supply Current | 0.8 A |
| Primary Protection | Internal 4 A time-delayed fuse |
| Secondary Protection | Overload, overvoltage, and short-circuit protection |
| Insulation Resistance | At least 100 MΩ |
| Local Indicators | OK, 24 V sensor supply, BAT |
| Dimensions Provided | 95 × 180 × 260 mm |
| Weight | 0.62 kg |
| Product Lifecycle | Discontinued |
| Platform | Modicon Premium PLC |
Note: Dimensions are the supplied listing values. Confirm the physical module, connector arrangement, and rack mounting drawing before preparing a replacement or cabinet layout.
The TSXPSY5500M receives AC power from the industrial electrical supply and converts it into regulated DC outputs for the Modicon Premium automation platform.
Its operation involves several important stages.
The module accepts either 100–120 V AC or 200–240 V AC within the specified input ranges. It is designed for 50/60 Hz electrical networks, with an operating frequency range of 47–63 Hz.
The incoming AC supply is processed by the internal power conversion circuitry. The resulting DC power is distributed through the module’s secondary output circuits.
Before installation, the supply voltage must be checked against the module’s permitted input range. Applying an incorrect voltage can damage the power supply or cause unstable operation.
The TSXPSY5500M provides a 5 V DC output with a rated current of up to 7 A and a documented power rating of 35 W.
This output is primarily associated with the power requirements of the PLC rack and its electronic modules. The processor and other rack components depend on a stable supply to execute control operations and process field information.
The available output capacity must be evaluated against the actual rack configuration. Adding modules increases the total power demand, so the rack’s power budget should be checked before expansion.
The module also provides 24 V DC power for relay and sensor-related circuits. The documented current ratings are 0.8 A for the relay power supply and 0.8 A for the sensor power supply.
These outputs support compatible control components that require 24 V DC. They can help simplify power distribution within a Premium PLC installation by providing auxiliary power from the rack supply module.
The current requirements of connected devices must remain within the specified output limits.
The TSXPSY5500M includes an internal time-delayed 4 A primary fuse. Its secondary circuits provide protection against overload, overvoltage, and short circuits.
These protection functions help reduce the risk of damage caused by abnormal electrical conditions. They do not replace suitable upstream protection or correct wiring practices.
Local LEDs provide information about the power supply’s operating condition.
These indicators help maintenance personnel perform initial checks when troubleshooting a PLC rack. They should be considered together with controller diagnostics and the actual electrical measurements.
The TSXPSY5500M plays an important role in the power architecture of a Modicon Premium PLC station. Although it does not execute control logic, it supplies the electrical power required by the controller and related automation components.
The PLC processor requires stable DC power to execute its program, process input signals, update outputs, and communicate with other devices.
If the power supply becomes unstable or its capacity is exceeded, the controller may experience unexpected resets, fault conditions, or loss of operation. Correct power supply selection is therefore essential for maintaining system availability.
Digital and analog I/O modules form the interface between the PLC and field devices. Depending on the rack configuration, these modules require power from the PLC backplane and may also require external field power.
The TSXPSY5500M supports the internal power requirements specified for its compatible rack arrangement. Engineers must distinguish between the module’s internal rack supply and the external power required by field sensors and actuators.
The 24 V DC outputs support compatible sensor and relay circuits. These supplies can be used as part of the control system’s auxiliary power arrangement.
Before connecting devices, calculate their combined current consumption and confirm that it remains within the output ratings. Devices with high inrush current or unusual electrical characteristics may require separate power supplies.
Communication modules rely on a stable PLC power environment to maintain their operation. A correctly sized and functioning power supply helps support communication between the controller, distributed equipment, supervisory systems, and other automation devices.
The TSXPSY5500M therefore contributes indirectly to the availability of the wider automation system.
The TSXPSY5500M is primarily used in industrial installations built around the Modicon Premium PLC platform.
Manufacturing systems use PLCs to coordinate motors, sensors, actuators, and production sequences. The TSXPSY5500M supplies the power required by compatible controller racks and associated modules.
It may be found in production lines where the original Premium PLC architecture remains in service.
Industrial process installations often rely on PLCs to monitor operating conditions and control pumps, valves, temperature-related equipment, and other process devices.
The power supply supports the PLC hardware responsible for processing signals and executing control logic. Its condition is important for maintaining continuous operation.
Conveyors, sorting systems, lifting equipment, and automated material-handling machinery use PLC-based control systems to coordinate equipment movement.
A stable rack power supply helps the controller process sensor inputs and issue control commands according to the programmed sequence.
Packaging systems may use PLCs to control product feeding, positioning, filling, sealing, and inspection operations.
The TSXPSY5500M can support compatible Premium PLC installations that coordinate these machine functions.
Water treatment, building services, and industrial utility systems may use PLC-based control cabinets for monitoring and equipment control.
Where a Modicon Premium system remains installed, the TSXPSY5500M can serve as a replacement power supply to help maintain the existing control architecture.
Correct installation is necessary to ensure that the TSXPSY5500M operates reliably and supplies the required power to the PLC rack.
Before connecting the module, identify the available AC supply and confirm that it falls within the specified range:
The input frequency must be within the specified 47–63 Hz range.
Never assume that an existing cabinet’s supply voltage is correct simply because a previous power supply was installed in the same position.
The TSXPSY5500M is designed for the Modicon Premium platform and has a double-format module design.
Check the PLC rack type, mounting position, connector arrangement, and power requirements before installation. A module from another Schneider Electric product family should not be considered interchangeable solely because its dimensions appear similar.
Calculate the power requirements of the installed processor, I/O modules, communication modules, and other rack components.
The TSXPSY5500M provides 50 W of total useful secondary power, distributed across its documented outputs. The 5 V DC and 24 V DC output requirements must be evaluated separately to avoid exceeding the permitted limits.
If additional modules are added to the rack, repeat the power-budget calculation before commissioning.
Inspect the AC input wiring, protective devices, grounding, and rack connections before energizing the module.
The manufacturer specifies an internal 4 A time-delayed primary fuse. Upstream protection and switching equipment should also be selected according to the installation requirements and applicable electrical codes.
After installation, verify the local indicators and check that the expected output voltages are present.
The OK and sensor-voltage indicators provide useful initial information. If the BAT indicator reports a fault, investigate the associated battery-related condition rather than assuming that the main power conversion stage is defective.
Once the power supply has been verified, check the controller’s operating status, module recognition, communication links, and I/O operation.
Record the rack configuration and any relevant maintenance information. This helps future technicians identify the installed hardware and troubleshoot power-related problems.
The TSXPSY5500M is part of a Modicon Premium PLC installation. Its correct operation depends on the compatible rack and the power requirements of the installed modules.
| Component | Function | Integration Considerations |
|---|---|---|
| Modicon Premium PLC rack | Provides the mounting and electrical backplane | Confirm rack compatibility and power requirements |
| Premium processor module | Executes PLC programs and control logic | Check processor power consumption |
| Digital input modules | Receive signals from switches and sensors | Verify rack and field-side power arrangements |
| Digital output modules | Control relays, solenoids, and other actuators | Check output module power requirements |
| Analog input modules | Acquire process measurement signals | Confirm module compatibility and external field power |
| Analog output modules | Provide analog control signals | Verify rack power and field wiring |
| Communication modules | Connect the PLC to industrial networks | Check the specific Premium platform configuration |
| 24 V DC sensors | Provide field status signals | Keep total sensor current within the supply rating |
| Relay circuits | Support compatible control and switching functions | Observe the 24 V DC output limit |
| Upstream protective device | Provides input-side electrical protection | Select according to installation requirements |
The table describes typical system relationships. It does not mean that these components are included with the TSXPSY5500M.
The TSXPSY5500M has been discontinued. Schneider Electric identifies the BMXCPS3540T from the Modicon X80 range as a recommended replacement in its product information.
However, the BMXCPS3540T is not automatically a direct plug-in replacement for a Modicon Premium rack. It belongs to a different automation platform and may require changes to the rack, controller, wiring, and system configuration.
| Alternative Model | Product Family | Replacement Considerations |
|---|---|---|
| TSXPSY5500M | Modicon Premium | Original model for like-for-like maintenance |
| TSXPSY5520M | Modicon Premium | Different input supply arrangement; verify output and rack requirements |
| TSXPSY8500M | Modicon Premium | Different output power configuration; not a direct substitute |
| TSXPSY2600M | Modicon Premium | Different power rating and output characteristics |
| BMXCPS3540T | Modicon X80 | Schneider-listed replacement option requiring platform compatibility assessment |
Before choosing a replacement, compare:
For an existing Premium PLC installation, a verified TSXPSY5500M replacement is generally the simplest maintenance approach. A platform migration should be treated as an engineering project rather than a routine power supply exchange.
The module supports both 100–120 V AC and 200–240 V AC supply ranges, allowing it to operate in different industrial electrical environments within its specified limits.
It provides 5 V DC power for the PLC rack and 24 V DC power for compatible relay and sensor circuits.
The documented total useful secondary power is 50 W, distributed across the module’s output circuits.
The module includes primary fuse protection and secondary overload, overvoltage, and short-circuit protection.
The OK, sensor-voltage, and BAT LEDs provide basic operating information that can assist maintenance personnel during troubleshooting.
The TSXPSY5500M is designed for compatible Modicon Premium PLC racks, making it relevant to maintenance and spare-parts requirements in existing installations.
The TSXPSY5500M is a power supply module designed for the Modicon Premium Automation Platform. It converts AC input power into DC outputs required by compatible PLC rack components.
It supports 100–120 V AC and 200–240 V AC nominal input supplies. The documented operating ranges are 85–140 V AC and 190–264 V AC.
The module provides 50 W of total useful secondary power, including 35 W at 5 V DC and 19 W at 24 V DC.
The documented 5 V DC output current is 7 A.
The module provides separate 24 V DC supplies for relay and sensor applications, each rated at 0.8 A according to the product specifications.
Yes. The secondary circuits include overload, overvoltage, and short-circuit protection. The primary circuit also has an internal 4 A time-delayed fuse.
The module has three local indicators: OK for the presence of required voltages, a 24 V sensor supply indicator, and a BAT indicator for battery fault status.
It is designed for the Modicon Premium platform, not as a direct power supply for every Schneider PLC family. M340 and M580 systems use their own platform-specific power supply products and rack arrangements. Compatibility must be confirmed before substitution.
The model has been discontinued. Schneider Electric lists it as discontinued and identifies December 31, 2026, as its end-of-service date. Availability through spare-parts suppliers may vary.
Confirm the complete model number, physical condition, input voltage requirements, output ratings, connector condition, and compatibility with the installed Premium rack. For used or refurbished units, request photographs and available functional test information.
When purchasing a TSXPSY5500M, begin by checking the complete model number on the existing module. Confirm that the replacement has the same input voltage requirements, output ratings, module format, and rack interface.
For industrial spare-parts procurement, it is useful to request clear photographs of the front label, terminals, and connector area. Confirm the product’s condition, testing status, warranty terms, and whether it is supplied with any accessories.
Because the product is discontinued, stock availability and service arrangements may vary. A supplier’s description should be compared with the original manufacturer specifications rather than relying only on a general product-family name.
For maintenance, inspect the power supply’s wiring, ventilation, terminals, and status indicators. Monitor the PLC rack for unexpected resets, voltage-related faults, or abnormal operating conditions. If the module is replaced, verify the output rails and check the controller and I/O modules before returning the system to production.
When considering the BMXCPS3540T or another Modicon X80 power supply as an upgrade path, evaluate the complete PLC architecture. A change of platform may involve replacing the rack, processor, I/O modules, communication hardware, wiring, and application program.
The Schneider Electric TSXPSY5500M Modicon Premium Power Supply Module provides 50 W of useful secondary power for compatible PLC rack installations. It supports 100–120 V AC and 200–240 V AC input supplies and provides 5 V DC and 24 V DC outputs for controller, relay, and sensor-related power requirements.
With integrated electrical protection and local status indicators, the TSXPSY5500M is an important component in existing Modicon Premium automation systems. Since the model has been discontinued, accurate identification, output verification, and rack compatibility checks are essential when sourcing a replacement or maintaining an installed PLC system.