The Schneider Electric NS1000N Circuit Breaker is an industrial low-voltage circuit protection device from the ComPacT NS family. Designed for electrical distribution systems, it helps protect power circuits against overloads and short circuits while providing a means of isolation for maintenance and electrical system management.
The NS1000N belongs to the ComPacT NS630b–1600 product range and is associated with a rated current of up to 1000 A. It is intended for applications where substantial current-carrying capacity and reliable circuit interruption are required, including industrial distribution panels, manufacturing facilities, commercial buildings, and large electrical installations.
Circuit breakers are essential components in power distribution systems. Under normal operating conditions, they allow electrical current to flow to connected equipment. When an abnormal current condition occurs, the appropriate protection mechanism operates to interrupt the circuit and limit potential damage to cables, electrical equipment, and downstream loads.
The NS1000N series offers different configurations, including fixed and withdrawable mounting arrangements, manual and electrical operation, and different trip-unit options. Depending on the selected configuration, the breaker may use an electronic Micrologic trip unit or be supplied as a basic frame requiring a separately selected protection unit.
For industrial maintenance and replacement projects, identifying the complete product configuration is important. The NS1000N model name alone does not establish the number of poles, trip-unit type, operating mechanism, or accessory arrangement. These details should be checked against the product nameplate and original order information before installation.
The supplied dimensions are 327 × 210 × 147 mm, with a listed weight of 14 kg. These values correspond to a documented NS1000N configuration, although other variants may have different physical arrangements and weights.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Family | ComPacT NS |
| Model | NS1000N |
| Product Type | Low Voltage Circuit Breaker |
| Device Application | Electrical Power Distribution |
| Rated Current | Up to 1000 A |
| Rated Operational Voltage | Up to 690 V AC |
| Rated Frequency | 50/60 Hz |
| Breaking Capacity at 380/415 V AC | 50 kA Icu for the documented N-performance configuration |
| Utilization Category | Category B |
| Standard | IEC 60947-2 |
| Rated Insulation Voltage | Configuration-dependent; up to 1000 V AC in documented variants |
| Rated Impulse Withstand Voltage | 8 kV in documented configurations |
| Number of Poles | Configuration-dependent |
| Mounting Type | Fixed or withdrawable, depending on configuration |
| Operating Mechanism | Manual or electrical, depending on configuration |
| Trip Unit | Configuration-dependent; Micrologic options available |
| Dimensions Provided | 327 × 210 × 147 mm |
| Weight Provided | 14 kg |
| Typical Application | Industrial and commercial low-voltage distribution |
Important: The specifications above describe the NS1000N product family and documented configurations. Exact electrical ratings, pole arrangement, trip-unit functions, and operating mechanism must be confirmed from the complete catalog number and product nameplate.
The NS1000N circuit breaker is designed to control and protect electrical distribution circuits. Its operating principle combines mechanical switching with a protection mechanism that detects abnormal electrical conditions and initiates circuit interruption.
Under normal operating conditions, the circuit breaker’s contacts remain closed, allowing current to pass from the incoming supply to the connected electrical load.
The breaker can be opened manually or through an electrical operating mechanism, depending on its configuration. Opening the contacts isolates the protected circuit and supports maintenance, inspection, and controlled shutdown procedures.
An overload occurs when the current flowing through a circuit remains above its permitted operating level. If this condition continues, conductors and connected equipment may overheat.
Where an appropriate thermal or electronic overload-protection function is installed, the breaker monitors the current and operates according to its configured protection curve.
For Micrologic 2.0 configurations, long-time protection settings can be adjusted within the permitted range. This allows protection to be coordinated with the characteristics of the connected circuit.
A short circuit can produce a very high current in a short period. If not interrupted promptly, it may cause serious thermal and mechanical stress.
The NS1000N family includes configurations with instantaneous short-circuit protection. When the detected current reaches the applicable trip threshold, the protection mechanism initiates opening of the circuit breaker.
The documented N-performance configuration provides a 50 kA ultimate short-circuit breaking capacity at 380/415 V AC. The actual breaking capacity must be checked at the intended operating voltage and against the selected configuration.
Some NS1000N variants use electronic Micrologic trip units. These units monitor electrical current and apply configured protection settings.
Depending on the trip-unit type, available functions may include long-time overload protection and instantaneous short-circuit protection. More advanced configurations within the broader ComPacT range may provide additional protection or measurement features.
The specific functions should never be assumed from the NS1000N frame designation alone. Confirm the installed trip unit and its protection capabilities.
The breaker can also serve as an isolation device when the selected version is approved for that purpose and installed according to the applicable electrical standards.
Before maintenance, the circuit must be isolated using the prescribed procedures. Personnel should verify the absence of hazardous voltage and follow the site’s lockout and electrical safety requirements.
The NS1000N circuit breaker is commonly used as a major protection component in low-voltage distribution arrangements. It can be installed at an incoming supply point, a main distribution section, or a large feeder circuit, depending on the electrical design.
In a main distribution panel, the breaker can protect a high-current electrical feeder supplying downstream distribution equipment. Its rated-current capacity makes it suitable for installations where smaller circuit breakers would not provide the required current rating.
The final selection must account for calculated load current, cable capacity, prospective short-circuit current, and coordination with upstream and downstream protective devices.
Industrial facilities contain motors, production lines, transformers, control cabinets, and other electrical loads. A properly selected circuit breaker helps protect the associated distribution circuits against abnormal current conditions.
The NS1000N can be incorporated into a coordinated protection system designed around the electrical characteristics of the installation.
Where compatible auxiliary contacts, trip indication, or electrical operating accessories are installed, the breaker may provide status information to a supervisory or building-management system.
These signals can help operators identify whether the breaker is open, closed, or has operated under a fault condition. The availability of each signal depends on the installed accessories.
A circuit breaker provides a controlled switching point for electrical maintenance. Fixed and withdrawable versions offer different installation and servicing arrangements.
A withdrawable configuration can support removal from its connected position without dismantling the entire switchboard, provided the equipment is designed for that procedure and the manufacturer’s safety instructions are followed.
The Schneider Electric NS1000N is designed for low-voltage power distribution applications requiring high current capacity and short-circuit protection.
Large manufacturing facilities often use main distribution boards to divide incoming electrical power among production areas and supporting systems.
The NS1000N can be used as a main or feeder circuit breaker where its current rating and breaking capacity match the installation requirements.
Factories contain multiple production lines, motors, process machines, and auxiliary electrical systems. A suitable main or feeder breaker helps protect the electrical distribution circuits supplying these loads.
The NS1000N may be incorporated into switchboards serving manufacturing equipment, provided the electrical design confirms its suitability.
Large commercial facilities require electrical distribution systems capable of supplying lighting, HVAC equipment, elevators, and other building services.
A 1000 A circuit breaker may be used in a main distribution or high-capacity feeder position, depending on the building’s load calculations and fault-level requirements.
Data centers and other critical facilities use carefully coordinated electrical distribution systems to supply servers, cooling equipment, UPS systems, and supporting infrastructure.
A circuit breaker such as the NS1000N may form part of a distribution arrangement where its protection characteristics and switching configuration meet the engineering requirements.
Redundancy and selectivity must be designed at the system level rather than assumed from the breaker itself.
Industrial substations and facility distribution rooms may use high-current low-voltage breakers to protect outgoing feeders and distribution sections.
The NS1000N can be considered for suitable applications where its rated voltage, breaking capacity, insulation characteristics, and mounting arrangement meet the system specification.
Correct installation is essential for electrical safety and dependable circuit protection.
Before installation, confirm the system voltage, frequency, rated current, and prospective short-circuit current.
The NS1000N family includes configurations rated up to 1000 A and 690 V AC. The applicable breaking capacity varies with voltage and configuration.
The selected breaker must have an adequate breaking capacity for the fault level at its installation point.
The NS1000N range includes different pole arrangements. The number of poles and protected-pole configuration must match the electrical system.
Do not assume that every NS1000N unit is a three-pole breaker. Verify the nameplate and complete catalog number before connecting the unit.
The trip unit determines the protection functions and available adjustment settings.
If the application requires a Micrologic 2.0 unit, confirm that the breaker is equipped with the correct trip unit and that its long-time and instantaneous protection settings can be coordinated with the installation.
For a basic-frame product supplied without a trip unit, the appropriate protection unit must be selected separately.
The supplied dimensions are 327 × 210 × 147 mm. Confirm the physical dimensions and required clearances against the manufacturer’s installation drawings for the exact variant.
The switchboard must provide suitable mounting support, ventilation, conductor access, and space for operation and maintenance.
Fixed and withdrawable versions have different installation requirements. Their mechanical arrangements should not be treated as interchangeable.
Incoming and outgoing conductors must be selected according to rated current, installation temperature, conductor material, terminal requirements, and applicable electrical standards.
Use the specified terminal hardware and tightening torque. Poor connections can cause overheating, excessive contact resistance, and equipment damage.
Where an adjustable trip unit is installed, set the protection parameters according to the electrical coordination study.
Long-time pickup, delay, and instantaneous settings must protect the connected conductors and equipment while maintaining appropriate selectivity with downstream devices.
Protection settings should be documented and reviewed by qualified electrical personnel.
Before energizing the installation, inspect the mounting, conductor connections, grounding arrangements, mechanical operation, and accessory wiring.
Verify the trip-unit configuration and protection settings. Perform the tests required by the project specification and applicable standards before returning the circuit to normal service.
The NS1000N is normally installed as part of a complete low-voltage distribution system. Its accessories and associated components must be selected according to the exact breaker version.
| Component | Function | Compatibility Considerations |
|---|---|---|
| Micrologic trip unit | Provides electrical protection functions | Confirm the correct trip-unit type and compatibility with the breaker frame |
| Auxiliary contacts | Provide breaker status signals | Verify contact arrangement and accessory compatibility |
| Shunt trip release | Allows remote electrical tripping | Confirm the correct operating voltage and accessory type |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Check rated control voltage and breaker compatibility |
| Motor mechanism | Enables electrical operation | Applicable only to compatible electrically operated versions |
| Rotary handle | Provides manual operating control | Select the correct mechanism for the breaker arrangement |
| Connection terminals | Connect incoming and outgoing conductors | Verify conductor size, terminal type, and tightening torque |
| Distribution busbars | Distribute power within the switchboard | Confirm current rating, connection dimensions, and short-circuit withstand |
| Switchboard enclosure | Provides mounting and environmental protection | Verify mounting arrangement, clearances, and enclosure requirements |
Not every accessory is included with every NS1000N breaker. Confirm the supplied bill of materials before ordering replacement parts.
When replacing an NS1000N, the new breaker must match the electrical and mechanical requirements of the installation.
| Alternative Product Family | Replacement Considerations |
|---|---|
| Schneider Electric ComPacT NS630b–1600 | Related product family; verify frame, trip-unit compatibility, and exact mechanical configuration |
| Schneider Electric ComPacT NS new generation | May be considered for an upgrade, subject to switchboard and protection coordination review |
| Schneider Electric MasterPact range | A possible alternative for selected higher-level distribution applications, depending on system requirements |
| Other Schneider Electric low-voltage breakers | Select according to rated current, voltage, breaking capacity, and protection functions |
Before approving a replacement, compare:
A breaker with the same 1000 A current rating is not automatically a direct replacement. Its breaking capacity, protection curve, mechanical arrangement, and accessories must also be suitable.
The NS1000N family includes configurations rated up to 1000 A, making it suitable for high-current low-voltage distribution applications.
Documented N-performance configurations provide 50 kA ultimate breaking capacity at 380/415 V AC. The correct rating must be verified for the selected version and system voltage.
The product family supports different trip-unit arrangements, allowing the protection configuration to be selected according to the application.
The NS1000N is designed for use in industrial and commercial low-voltage switchboards where dependable circuit interruption and isolation are required.
Depending on the selected version, fixed and withdrawable mounting options are available to support different switchboard designs and maintenance strategies.
The family includes manual and electrically operated configurations. This allows the breaker arrangement to be matched to the required local or remote operating strategy.
The ComPacT NS range has been used in industrial and commercial electrical distribution systems. Accurate identification of the original configuration helps maintenance teams plan repairs and replacement projects.
The NS1000N is a low-voltage circuit breaker from the Schneider Electric ComPacT NS family. It is designed for electrical distribution protection, with configurations rated up to 1000 A.
The documented rated current is up to 1000 A at 50 °C. Confirm the exact breaker configuration and its nameplate before applying this rating.
The N-performance configuration provides a 50 kA ultimate short-circuit breaking capacity at 380/415 V AC. The breaking capacity varies with operating voltage, so the correct rating must be checked for the installation.
Depending on the installed trip unit, the breaker can provide overload and short-circuit protection. Micrologic 2.0 configurations include long-time and instantaneous protection functions.
The ComPacT NS1000N family includes different pole configurations. The exact number of poles must be confirmed from the full catalog number and product label.
Electrically operated configurations can support remote operation through the appropriate operating mechanism. A manually operated version does not automatically include this function.
A fixed breaker is installed directly in its mounting position. A withdrawable version uses a compatible drawout arrangement that allows the breaker to be moved between connected, disconnected, and other designated positions according to the equipment design.
Documented configurations are suitable for isolation in accordance with EN/IEC 60947-2. Confirm the suitability marking and applicable operating instructions for the exact breaker.
Check the complete catalog number, rated current, operating voltage, breaking capacity, pole arrangement, trip unit, mounting type, operating mechanism, and installed accessories. Physical dimensions and terminal arrangements should also be compared.
No. The 14 kg figure is consistent with a documented NS1000N configuration equipped with a Micrologic 2.0 trip unit. Other configurations, including basic frames and withdrawable arrangements, may have different weights.
When sourcing a Schneider Electric NS1000N circuit breaker, begin by identifying the complete catalog number and the configuration installed in the electrical panel.
Confirm the rated current, system voltage, breaking capacity, number of poles, trip-unit type, and mounting arrangement. If the existing breaker is electrically operated, check the motor mechanism and associated control accessories. If remote monitoring is required, verify the auxiliary contacts and available signaling functions.
For used or surplus equipment, request clear photographs of the nameplate, terminals, operating mechanism, and trip unit. Check the mechanical condition, contact condition, signs of overheating, and available test records. Confirm whether the product is supplied as a complete circuit breaker or as a basic frame without a trip unit.
During maintenance, inspect the breaker according to the manufacturer’s procedures and the facility’s electrical maintenance plan. Check terminal connections, signs of excessive heating, mechanical operation, and the condition of accessories. Protection settings should be recorded and reviewed whenever the electrical distribution system is modified.
Circuit breaker testing and servicing should be performed by qualified personnel using appropriate procedures and equipment. Never assume that a breaker is safe to handle solely because its operating handle is in the open position.
The Schneider Electric NS1000N Circuit Breaker is a high-current low-voltage protection device from the ComPacT NS family. With configurations rated up to 1000 A and a documented 50 kA breaking capacity at 380/415 V AC, it is designed for industrial and commercial electrical distribution applications.
The product family supports different pole arrangements, trip units, mounting methods, and operating mechanisms. These variations make complete catalog-number verification essential when purchasing, installing, or replacing the breaker.
For maintenance and procurement projects, confirming the electrical ratings, protection functions, mechanical arrangement, and supplied accessories helps ensure that the selected NS1000N configuration is appropriate for the intended distribution system.