Product Overview The Schneider Electric MT32N2 Circuit Breaker is associated with the Masterpact MT family of low-voltage air circuit breakers (ACBs). Designed for industrial and commercial power distri……
Schneider MT32N2 Circuit Breaker
  • Schneider
  • MT32N2
  • Circuit Breaker
  • France
  • 301 x 196 x 276 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Schneider MT32N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT32N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT32N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT32N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MT32N2 Circuit Breaker is associated with the Masterpact MT family of low-voltage air circuit breakers (ACBs). Designed for industrial and commercial power distribution systems, this type of circuit breaker provides high-current switching, circuit isolation, and protection against electrical faults.

Air circuit breakers are commonly installed in main distribution boards, power control centers, industrial switchboards, and other electrical distribution assemblies. They protect electrical circuits by detecting abnormal current conditions and interrupting the power supply when the configured protection limits are exceeded.

The MT32N2 designation is associated with the 3200 A frame class of the Masterpact MT range. This class of equipment is intended for high-capacity distribution applications where the electrical system requires substantial current-carrying capability and coordinated protection.

The circuit breaker forms part of a larger protection system. Its actual protection characteristics depend on the installed trip unit, breaker configuration, and electrical accessories. Depending on the specific assembly, features may include overload protection, short-circuit protection, earth-fault protection, auxiliary signaling, and remote operating functions.

For replacement and maintenance projects, identifying the complete breaker configuration is essential. The MT32N2 designation alone should not be used to assume a particular pole arrangement, trip-unit type, breaking capacity, or fixed/drawout configuration.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Model MT32N2
Product Family Masterpact MT
Product Type Air Circuit Breaker
Application Low-voltage power distribution
Frame Class 3200 A
Protection Functions Dependent on installed trip unit
Rated Operational Voltage Verify from nameplate
Breaking Capacity Verify from exact breaker configuration
Number of Poles Verify from nameplate
Trip Unit Verify installed type
Mounting Arrangement Verify fixed or drawout configuration
Dimensions Provided 301 × 196 × 276 mm
Weight Provided 14 kg
Manufacturer Schneider Electric

Important: The dimensions and weight are supplied listing values, not independently confirmed manufacturer specifications for MT32N2. Confirm the actual product and dimensional drawing before using them for panel design or shipping.

Function and Working Principle

The MT32N2 belongs to a category of circuit breakers designed to protect high-capacity electrical distribution systems. Its operating principle involves monitoring electrical conditions and interrupting the circuit when a fault or abnormal operating condition is detected by the protection system.

1. Overload Protection

An overload occurs when a circuit carries more current than its permitted operating level for an extended period.

The installed protection unit monitors the current and applies its configured overload protection characteristics. When the detected condition exceeds the protection threshold for the specified time, the breaker initiates an opening operation.

This function helps protect cables, busbars, transformers, and connected electrical equipment against excessive thermal stress.

2. Short-Circuit Protection

A short circuit can produce a very high fault current within a short period. Without appropriate protection, the resulting electrical and thermal stresses can damage equipment and create serious safety hazards.

The circuit breaker’s trip system detects qualifying short-circuit conditions and initiates interruption. The actual interruption capability depends on the breaker’s rated breaking capacity and the electrical characteristics of the installation.

The prospective short-circuit current at the installation point must be calculated before selecting the breaker.

3. Earth-Fault Protection

Depending on the installed trip unit and accessories, the breaker assembly may support earth-fault protection.

Earth faults can occur when current flows through an unintended path to ground or exposed conductive parts. Appropriate protection settings help detect these conditions and disconnect the affected circuit.

The availability and configuration of earth-fault protection must be confirmed for the specific MT32N2 assembly.

4. Switching and Electrical Isolation

Air circuit breakers are also used for switching and isolation in low-voltage distribution systems.

They allow authorized operators and maintenance personnel to control electrical circuits according to the equipment’s operating procedures. The exact operating mechanism may be manual or electrically operated, depending on the configuration.

A circuit breaker should not be treated as a substitute for all required maintenance isolation procedures. Lockout, verification of isolation, and applicable electrical safety practices remain necessary.

5. Fault Indication and Monitoring

Depending on the installed accessories, the breaker can provide information about its operating state and trip conditions.

Auxiliary contacts and signaling devices may be used to communicate breaker status to PLC systems, electrical monitoring equipment, or supervisory control systems.

The available signals depend on the actual accessories installed in the breaker.

Role in Industrial Power Distribution Systems

The MT32N2 can serve as a major switching and protection component in a low-voltage distribution architecture.

Main Distribution Board Protection

In industrial facilities, a main distribution board receives electrical power from a transformer, generator, or upstream distribution system.

An appropriately selected air circuit breaker can provide protection and switching for the incoming supply or a major distribution section. Its current rating and fault-interruption capability must match the electrical design.

Busbar Section Protection

Large distribution assemblies often contain multiple busbar sections supplying different areas of a facility.

Circuit breakers can be used as incoming, outgoing, or bus-coupling devices, depending on the switchboard design. Protection coordination is important to ensure that a fault in one section does not unnecessarily interrupt the entire electrical system.

Transformer Feeder Protection

Air circuit breakers may be installed on the low-voltage side of distribution transformers.

The breaker must be coordinated with the transformer characteristics, downstream protective devices, cable ratings, and expected short-circuit current.

Generator and Backup Power Systems

Industrial facilities may use generators and backup power systems to maintain critical operations.

A suitable circuit breaker can provide switching and protection within the generator distribution arrangement. Generator applications require careful consideration of fault-current characteristics, synchronization, and protection coordination.

PLC and SCADA Monitoring

In modern electrical distribution systems, breaker status and fault information may be integrated into a PLC, SCADA, or power-management system.

With suitable auxiliary contacts and communication accessories, operators can monitor breaker conditions and coordinate maintenance activities. Communication capability should be confirmed from the installed accessory configuration.

Industrial Applications

1. Manufacturing Facilities

Large manufacturing plants require reliable electrical distribution for production lines, motors, pumps, compressors, and auxiliary equipment.

A high-capacity air circuit breaker can provide incoming or feeder protection in appropriately designed low-voltage switchboards.

2. Power Distribution Substations

Low-voltage distribution sections in substations require switching and protection equipment capable of handling substantial electrical loads.

The Masterpact MT family is designed for this type of distribution application, subject to correct voltage, current, and fault-level selection.

3. Data Centers

Data centers depend on stable electrical distribution for servers, cooling systems, UPS equipment, and other critical infrastructure.

Air circuit breakers may be used in main switchboards and distribution assemblies to support protection coordination and controlled power distribution.

4. Oil and Gas Facilities

Oil and gas installations contain electrical distribution networks serving pumps, compressors, control systems, and process equipment.

Circuit breaker selection must account for the installation’s fault levels, environmental conditions, protection requirements, and applicable industry standards.

5. Commercial Buildings and Infrastructure

Large commercial buildings, hospitals, transportation facilities, and industrial campuses require high-capacity distribution equipment.

Air circuit breakers may be installed in main switchboards to protect incoming supplies and major distribution feeders.

6. Heavy Industrial Equipment

Steel plants, mining facilities, and other heavy industrial installations use substantial electrical loads.

Appropriately selected circuit breakers provide switching and fault protection for distribution sections supplying heavy machinery and auxiliary systems.

Installation and System Integration

Correct installation is essential for the safe and reliable operation of a high-current air circuit breaker.

1. Verify the Complete Model Configuration

Before installation, confirm the complete model reference and nameplate information.

Important details include:

  • Rated operational voltage.
  • Rated current.
  • Number of poles.
  • Rated short-circuit breaking capacity.
  • Trip-unit type and protection settings.
  • Fixed or drawout mounting arrangement.
  • Electrical or manual operating mechanism.
  • Auxiliary contacts and communication accessories.

These details determine whether the breaker is suitable for the intended switchboard.

2. Check Switchboard Compatibility

The circuit breaker must be compatible with the switchboard’s mechanical arrangement and electrical connections.

Check mounting dimensions, busbar spacing, connection orientation, terminal arrangement, and required clearances.

Do not rely exclusively on the supplied dimensions of 301 × 196 × 276 mm. Obtain the correct dimensional drawing for the actual breaker configuration before modifying or manufacturing a switchboard.

3. Electrical Connection

The main electrical connections must be designed for the rated current and expected fault conditions.

Busbars, conductors, connection hardware, and protective devices must comply with the applicable electrical standards and manufacturer instructions.

Connection surfaces should be inspected for contamination, corrosion, and mechanical damage before installation.

4. Protection Coordination

The breaker’s trip settings should be coordinated with upstream and downstream protective devices.

Protection coordination helps ensure that a fault is cleared by the protective device closest to the affected circuit whenever possible.

Engineers should evaluate overload, short-time, instantaneous, and earth-fault settings where those functions are available.

5. Control and Monitoring Integration

If the breaker includes suitable auxiliary contacts or communication accessories, it may be integrated with a PLC, SCADA system, or electrical monitoring platform.

Typical monitored information may include:

  • Open or closed status.
  • Trip indication.
  • Fault signaling.
  • Operating mechanism status.
  • Electrical measurements, where supported by the installed equipment.

The exact functions depend on the trip unit and accessories.

6. Commissioning and Functional Testing

Before energizing the switchboard, qualified personnel should inspect the mechanical installation, electrical connections, grounding, and protection configuration.

Functional testing should follow the manufacturer’s procedures and the applicable commissioning standards.

Protection testing should confirm that the installed trip unit and breaker operate according to the approved settings.

Compatible System Components

The MT32N2 is part of a larger low-voltage electrical distribution system. The following components may be used with suitable Masterpact MT configurations.

Component Function Compatibility Considerations
Micrologic trip unit Provides electronic protection and monitoring Confirm exact trip-unit compatibility
Auxiliary contacts Indicate breaker open/closed status Verify contact arrangement and ratings
Trip indication contacts Signal fault or trip conditions Confirm accessory type
Motor mechanism Supports electrically operated breaker functions Check model and operating voltage
Closing release Enables electrical closing operation Confirm control voltage and accessory compatibility
Opening release Enables remote opening operation Verify release type and voltage
Drawout chassis Supports withdrawable breaker installation Must match the breaker frame and configuration
Busbar assembly Provides main electrical connections Confirm current rating, spacing, and connection arrangement
PLC or SCADA system Monitors breaker status and system conditions Requires suitable auxiliary or communication interfaces
Low-voltage switchboard Houses and connects the breaker Verify mechanical and electrical compatibility

Not all listed components are included with the breaker. Their availability and compatibility must be checked against the exact product reference.

Alternative Models and Replacement Considerations

The Masterpact MT family includes different frame sizes and breaking-capacity versions. Selecting an alternative requires more than matching the product family or nominal current.

Related Model Description Replacement Considerations
MT16N2 Masterpact MT air circuit breaker Lower frame class; verify electrical requirements
MT20N2 Masterpact MT air circuit breaker Confirm rated current and breaking capacity
MT25N2 Masterpact MT air circuit breaker Check current rating and switchboard compatibility
MT32N1 Masterpact MT air circuit breaker Compare breaking-capacity class and configuration
MT32H1 Masterpact MT air circuit breaker Higher breaking-capacity class; verify exact specifications
MT32H2 Masterpact MT air circuit breaker Confirm voltage, breaking capacity, and accessories
MT40N2 Masterpact MT air circuit breaker Different frame rating; not a direct substitute without engineering review

Before selecting a replacement, compare:

  • Rated current and frame size.
  • Rated operational voltage.
  • Number of poles.
  • Ultimate and service breaking capacities.
  • Short-time withstand current.
  • Trip-unit functions and settings.
  • Fixed or drawout installation.
  • Main connection arrangement.
  • Auxiliary and communication accessories.
  • Switchboard dimensions and clearances.

A replacement breaker must be approved for the installation’s electrical fault level and protection coordination requirements.

Key Advantages

High-Current Distribution Capability

The Masterpact MT family is designed for low-voltage distribution systems requiring high current ratings. The MT32 frame class is associated with 3200 A applications.

Circuit Protection

With a compatible protection trip unit, the breaker can provide protection against overloads and short circuits. Additional functions depend on the installed configuration.

Industrial Switchboard Integration

The Masterpact MT family is designed for integration into industrial and commercial low-voltage distribution assemblies.

Flexible Configuration

Different trip units, operating mechanisms, mounting arrangements, and accessories may be available across the product family.

Remote Monitoring Possibilities

With suitable auxiliary and communication accessories, breaker status and selected operating information can be integrated into larger electrical monitoring systems.

Maintenance and Replacement Support

Correct identification of the breaker configuration helps maintenance teams source replacement equipment and plan switchboard servicing.

Technical FAQs

1. What is the Schneider Electric MT32N2?

The MT32N2 is identified as a Masterpact MT-series low-voltage air circuit breaker associated with the 3200 A frame class.

2. What is the rated current of the MT32N2?

The MT32 designation is associated with the 3200 A frame class. The actual rated current and applicable operating conditions should be confirmed from the nameplate and manufacturer documentation.

3. What protection functions does it provide?

Protection functions depend on the installed trip unit. Typical functions in the Masterpact MT family include overload and short-circuit protection, with additional functions available depending on the trip-unit configuration.

4. Can the MT32N2 be used in a main distribution board?

It may be used in a suitable low-voltage main distribution assembly when its electrical ratings, fault-interruption capability, mounting arrangement, and protection settings match the system design.

5. Can it be integrated with a PLC?

Yes, where the breaker is equipped with compatible auxiliary contacts or communication accessories. The available signals and communication functions depend on the installed hardware.

6. What is the difference between N and H breaking-capacity versions?

The N and H suffixes identify different breaking-capacity classes within the relevant product family. The exact values depend on rated voltage and the manufacturer’s published specifications. The correct class must be selected according to the prospective short-circuit current at the installation point.

7. Is the MT32N2 a fixed or drawout breaker?

The mounting arrangement must be confirmed from the complete product reference and physical unit. Do not assume that all breakers with the same frame designation use the same installation arrangement.

8. What should be checked before purchasing?

Verify the complete model reference, nameplate, current rating, voltage, pole configuration, trip unit, breaking capacity, mounting arrangement, accessories, and physical condition.

9. Are the supplied dimensions and weight confirmed?

The supplied listing values are 301 × 196 × 276 mm and 14 kg. They should be checked against the actual unit because similar figures are also associated with listings for other Masterpact MT models.

10. Why is protection coordination important?

Protection coordination helps ensure that the protective device nearest to a fault operates first where the system design permits. This can reduce unnecessary interruption to unaffected distribution sections.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric MT32N2, begin by confirming the complete model reference and the details printed on the breaker nameplate.

For high-current circuit breakers, the electrical configuration is particularly important. A breaker with a similar frame size may have a different breaking capacity, trip unit, number of poles, or mounting arrangement.

For used or refurbished equipment, request photographs of the nameplate, terminals, operating mechanism, and accessory compartment. Ask for available inspection and functional test records. Confirm whether the breaker is supplied with its drawout chassis, operating mechanism, trip unit, and other required accessories.

During maintenance, qualified personnel should inspect the main contacts, connection surfaces, operating mechanism, insulation components, and auxiliary circuits according to the manufacturer’s maintenance procedures.

Protection settings should be documented and reviewed whenever the electrical distribution system changes. Periodic inspection and appropriate testing help identify mechanical wear, connection problems, and abnormal operating conditions.

For replacement projects, engineers should evaluate the complete switchboard design rather than replacing the breaker based only on its nominal current rating.

Conclusion

The Schneider Electric MT32N2 Masterpact MT Circuit Breaker is associated with the 3200 A frame class and is intended for high-capacity low-voltage power distribution applications. It can serve as a switching and protection component in suitable industrial switchboards, distribution boards, and electrical infrastructure systems.

Its actual operating characteristics depend on the complete breaker configuration, including the trip unit, pole arrangement, breaking capacity, and mounting design. For procurement and replacement, confirming these details is essential to ensure electrical safety, system compatibility, and reliable operation.