• Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device
  • Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device
  • Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device
  • Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device
Product Overview The Allen Bradley 1788-CN2PAR is a redundant ControlNet to PROFIBUS-PA Linking Device designed to integrate PROFIBUS-PA process instruments into Allen-Bradley Logix automation systems. ……
Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device
  • Allen Bradley
  • 1788-CN2PAR
  • Linking Device
  • USA
  • 152 × 80 × 136 mm
  • 0.57 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen Bradley 1788-CN2PAR is a redundant ControlNet to PROFIBUS-PA Linking Device designed to integrate PROFIBUS-PA process instruments into Allen-Bradley Logix automation systems. It belongs to the Bulletin 1788 Linking Devices family and provides a direct communication connection between ControlNet and PROFIBUS-PA without requiring an intermediate PROFIBUS-DP network.

The device serves as a gateway between the controller-level network and field-level process instrumentation. On the ControlNet side, it uses two BNC connectors for single or dual ControlNet media connections. On the PROFIBUS-PA side, it provides two physical fieldbus ports, designated A and B, for connecting process instruments and supported network configurations.

One of its important features is integrated PROFIBUS-PA power conditioning. Each PA port provides up to 500 mA, allowing the linking device to supply conditioned power directly to the fieldbus network without requiring additional external power conditioners.

The 1788-CN2PAR supports up to 24 PROFIBUS-PA field devices. Its integration with Studio 5000 Logix Designer allows process variables, device status information, and diagnostic data to be accessed within the controller environment.

This makes the device particularly useful when integrating existing PROFIBUS-PA instrumentation into a ControlNet-based process control system.


Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley
Brand Owner Rockwell Automation
Model 1788-CN2PAR
Product Series Bulletin 1788 Linking Devices
Product Type ControlNet to PROFIBUS-PA Linking Device
Official Product Designation Redundant ControlNet to PROFIBUS-PA Linking Device
Controller Network ControlNet
Fieldbus Protocol PROFIBUS-PA
ControlNet Connectors 2 BNC Ports
ControlNet Media Single or Dual ControlNet Media
PROFIBUS-PA Ports 2 Physical Ports (A and B)
Maximum Field Devices 24
PA Port Output 500 mA per Port
Power Supply Input 24–32V DC, 0.75A
PA Power Output 0.5A at 24V DC per Single Trunk
PA Power Output 0.4A at 24V DC for Dual Trunk Configuration
Power Conditioning Built-in
Power Consumption 260 mA at 24V DC without Field Devices
Power Dissipation 12.24 W at 24V DC
Isolation Voltage 30V Continuous
Isolation Test Voltage 500V DC for 60 Seconds
Enclosure Type Open-Style
Configuration Software Studio 5000 Logix Designer
Configuration Interface Add-On Profile (AOP)
Device Diagnostics FDT/DTM Support and Built-in Web Server
Dimensions 152 × 80 × 136 mm
Weight 0.57 kg

Product Features

  • ControlNet-to-PROFIBUS-PA Integration: Establishes direct communication between ControlNet and PROFIBUS-PA networks without an intermediate PROFIBUS-DP layer.
  • Redundant ControlNet Media: Provides two BNC connectors for single or dual ControlNet media configurations.
  • Dual PROFIBUS-PA Ports: Offers two independent physical PA connections, designated A and B.
  • 24-Device Capacity: Supports up to 24 PROFIBUS-PA field devices.
  • Integrated Power Conditioning: Supplies conditioned power to the PA network without requiring additional external power conditioners.
  • 500 mA Per Port: Provides the specified current capacity for each physical PA port.
  • Studio 5000 Integration: Uses a dedicated Add-On Profile to simplify controller configuration and process variable mapping.
  • Field Device Diagnostics: Supports FDT/DTM technology for accessing instrument configuration and diagnostic information.
  • Built-in Display: Features a 128 × 128 pixel display for viewing network status, voltage, current, internal temperature, and field device communication quality.
  • Web-Based Monitoring: Includes a built-in web server for accessing network and field device information.

Product Working Principle

The 1788-CN2PAR operates as a communication gateway between ControlNet and PROFIBUS-PA. Its main function is to exchange process data between the Logix controller and connected field instruments.

The communication process involves several stages.

1. ControlNet Communication

The linking device connects to the ControlNet network through two BNC connectors. These connections support single or dual ControlNet media arrangements, allowing the device to participate in the existing controller communication architecture.

2. PROFIBUS-PA Communication

On the fieldbus side, the device provides two physical ports, A and B. These ports connect PROFIBUS-PA instruments such as pressure transmitters, temperature transmitters, flowmeters, and valve positioners.

3. Process Data Exchange

The linking device manages communication between the controller network and the PA field devices. Process variables are transferred into the Logix controller environment through predefined data structures.

Each configured field device can provide process variables and additional status information. The controller can access these values through the configured communication connections.

4. Fieldbus Power Conditioning

The 1788-CN2PAR incorporates built-in power conditioners for the PROFIBUS-PA network. It supplies conditioned DC power to the connected PA segments while supporting communication over the same fieldbus wiring.

5. Configuration and Diagnostics

The device uses an Add-On Profile in Studio 5000 Logix Designer for configuration. Field device parameters and diagnostics can also be accessed through supported FDT/DTM tools.

A simplified network arrangement is:

ControlLogix Controller → ControlNet Network → 1788-CN2PAR → PROFIBUS-PA Network → Process Instruments

The linking device handles communication and power conditioning between the two network levels rather than performing the process control algorithms itself.


Role in Allen-Bradley ControlNet and PROFIBUS-PA Control Architecture

Within an Allen-Bradley process automation system, the 1788-CN2PAR serves as the communication interface between ControlNet-based controllers and PROFIBUS-PA field instrumentation.

ControlNet provides the controller-level communication path, while PROFIBUS-PA connects process instruments that measure and regulate operating conditions throughout the plant.

The linking device allows these field instruments to communicate with the Logix controller without requiring a separate PROFIBUS-DP network layer.

System Component Function
1788-CN2PAR Connects ControlNet with PROFIBUS-PA
ControlLogix Controller Executes process control and automation logic
1756-CNB Provides ControlNet communication for ControlLogix systems
1756-CNBR Supports redundant ControlNet communication
ControlNet Coaxial Cable Provides the controller-side communication path
PROFIBUS-PA Trunk Cable Connects field instruments to the linking device
1788-FBJB4R Provides redundant PROFIBUS-PA junction connections
1788-FBJB6 Provides multiple PROFIBUS-PA field device connections
PROFIBUS-PA Transmitters Measure pressure, temperature, flow, and other process variables
PROFIBUS-PA Positioners Receive control commands for valve positioning
24V DC Power Supply Supplies operating power to the linking device

The 1788-CN2PAR is particularly useful in process installations where PROFIBUS-PA instrumentation must be incorporated into an existing ControlNet-based control architecture.


Industrial Applications

The 1788-CN2PAR is suitable for process automation environments where field-level PROFIBUS-PA instruments need to exchange information with Allen-Bradley Logix controllers.

Industrial Application Typical Use
Oil and Gas Integrating pressure and flow transmitters into ControlNet-based systems
Petrochemical Processing Connecting distributed process instruments to central controllers
Chemical Manufacturing Collecting temperature, pressure, and flow measurements
Power Generation Integrating field instrumentation into plant control networks
Water Treatment Connecting PROFIBUS-PA process measurement devices
Pharmaceutical Manufacturing Supporting communication with process instrumentation
Pulp and Paper Integrating fieldbus transmitters into distributed process control
Food and Beverage Connecting process measurement and valve control instruments
Refining Operations Linking field instrumentation with centralized control systems
Industrial Utilities Supporting distributed measurement and process monitoring

Installation and Maintenance

  1. Verify the Model Number: Confirm that 1788-CN2PAR is the required ControlNet to PROFIBUS-PA linking device.
  2. Check Power Requirements: Prepare a suitable 24–32V DC power supply that meets the specified electrical requirements.
  3. Inspect the Device: Examine the BNC connectors, PA terminals, power connections, display, and housing for visible damage.
  4. Prepare the Installation Location: Select a suitable control cabinet location with sufficient ventilation and protection for open-style equipment.
  5. Mount the Linking Device: Install the unit using the manufacturer’s specified mounting arrangement.
  6. Connect ControlNet Media: Connect the ControlNet coaxial cable to the appropriate BNC port. Configure single or dual media connections according to the network design.
  7. Connect PROFIBUS-PA Wiring: Connect the PA trunk wiring to ports A and B, observing the specified positive, negative, and shield terminal assignments.
  8. Check Network Topology: Verify the selected PA network arrangement and ensure that the connected field devices comply with the segment design.
  9. Connect the DC Power Supply: Wire the external 24–32V DC supply to the designated power terminals, observing correct polarity.
  10. Configure the Linking Device: Use Studio 5000 Logix Designer and the dedicated Add-On Profile to configure the device and connected PA instruments.
  11. Verify Network Communication: Check the display, status indicators, and controller diagnostics to confirm that the ControlNet and PROFIBUS-PA connections are operating correctly.
  12. Perform Routine Inspection: Periodically inspect the power connections, BNC connectors, PA wiring, grounding, and field device communication status.

Compatible System Components

Component Function
Allen-Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device
Allen-Bradley 1788-EN2PAR EtherNet/IP to PROFIBUS-PA Linking Device
Allen-Bradley 1788-FBJB4R 4-Way Redundant Intelligent Fieldbus Junction Box
Allen-Bradley 1788-FBJB6 6-Way Intelligent Fieldbus Junction Box
Allen-Bradley 1756-CNB ControlLogix ControlNet Bridge Module
Allen-Bradley 1756-CNBR ControlLogix Redundant ControlNet Bridge Module
Allen-Bradley ControlLogix Controller Executes process control logic
PROFIBUS-PA Field Instruments Process measurement and control devices
24V DC Power Supply External operating power source

Recommended Related Models

Model Product Type Application
Allen-Bradley 1788-EN2PAR EtherNet/IP to PROFIBUS-PA Linking Device EtherNet/IP to PROFIBUS-PA integration
Allen-Bradley 1788-CN2FFR ControlNet to FOUNDATION Fieldbus H1 Linking Device ControlNet to FOUNDATION Fieldbus integration
Allen-Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device EtherNet/IP to FOUNDATION Fieldbus integration
Allen-Bradley 1788-FBJB4R Redundant Intelligent Fieldbus Junction Box Redundant fieldbus connections
Allen-Bradley 1788-FBJB6 Intelligent Fieldbus Junction Box Multiple field instrument connections
Allen-Bradley 1756-CNBR ControlLogix Redundant ControlNet Bridge Module Redundant ControlNet communication

Key Advantages

  • Direct integration of ControlNet and PROFIBUS-PA networks.
  • Supports up to 24 field instruments.
  • Two independent PROFIBUS-PA physical ports.
  • Redundant ControlNet media connectivity.
  • Built-in PA power conditioning.
  • Studio 5000 configuration and controller integration.
  • Integrated display and web-based diagnostics.

Technical FAQs

1. How many PROFIBUS-PA field devices can the 1788-CN2PAR support?

The 1788-CN2PAR supports up to 24 PROFIBUS-PA field devices. The actual segment configuration must also account for cable length, current consumption, network topology, and fieldbus electrical requirements.

2. Does the 1788-CN2PAR require an external PROFIBUS-PA power conditioner?

No. The linking device incorporates built-in power conditioning for its PROFIBUS-PA network connections. Rockwell Automation specifies up to 500 mA per physical PA port.

3. What is the difference between 1788-CN2PAR and 1788-EN2PAR?

The 1788-CN2PAR connects PROFIBUS-PA field devices to a ControlNet network, whereas the 1788-EN2PAR provides the corresponding connection to an EtherNet/IP network. Both belong to the Bulletin 1788 PROFIBUS-PA linking device family.

4. Can the 1788-CN2PAR operate with redundant PROFIBUS-PA media?

Yes. The device supports redundant PA network configurations using its two physical ports. The appropriate trunk arrangement, junction boxes, field device connections, and configuration settings must be selected according to the system design.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501