• Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device
  • Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device
  • Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device
  • Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device
Product Overview The Allen Bradley 1788-EN2FFR is a redundant EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device designed to integrate process instrumentation into Allen-Bradley Logix-based automation……
Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device
  • Allen Bradley
  • 1788-EN2FFR
  • Linking Device
  • USA
  • 152 × 80 × 136 mm
  • 0.54 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus Linking Device

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen Bradley 1788-EN2FFR is a redundant EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device designed to integrate process instrumentation into Allen-Bradley Logix-based automation systems. It belongs to the Bulletin 1788 Linking Devices family and provides a communication gateway between EtherNet/IP controllers and FOUNDATION Fieldbus H1 field devices.

The device connects to an EtherNet/IP network through two Ethernet ports and provides two physical hardware ports for FOUNDATION Fieldbus H1 connections. Both H1 ports belong to the same logical fieldbus segment, allowing the network to be divided between two physical connection points.

The 1788-EN2FFR supports up to 16 FOUNDATION Fieldbus devices on a single H1 segment. Its built-in fieldbus power conditioning eliminates the need for a separate external FOUNDATION Fieldbus power conditioner in supported configurations.

Another important capability is its support for different media redundancy arrangements, including ring, split, and redundant trunk configurations. These options allow system integrators to select a network topology according to installation requirements.

The linking device is configured through Studio 5000 Logix Designer using a dedicated Add-On Profile (AOP). It also provides FOUNDATION Fieldbus host functionality, including Link Active Scheduler (LAS) capability, for coordinating communication between field instruments.

The 1788-EN2FFR is particularly suitable for process automation projects where existing FOUNDATION Fieldbus instrumentation needs to communicate with EtherNet/IP-based control systems.


Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley
Brand Owner Rockwell Automation
Model 1788-EN2FFR
Product Series Bulletin 1788 Linking Devices
Product Type EtherNet/IP to FOUNDATION Fieldbus Linking Device
Official Product Designation Redundant EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device
Controller Network EtherNet/IP
Fieldbus Protocol FOUNDATION Fieldbus H1
Ethernet Ports 2
Ethernet Cable Type CAT5 STP/UTP
H1 Hardware Ports 2
Logical H1 Segments 1
Maximum Field Devices 16 per H1 Segment
H1 Port Current Capacity 500 mA per Port
Power Supply Input 24–32V DC, 0.75A
FOUNDATION Fieldbus Output 0.5A at 24V DC, Single Trunk
FOUNDATION Fieldbus Output 0.4A at 24V DC, Dual Trunk
Power Conditioning Built-in
Fieldbus Host Functionality Supported
Link Active Scheduler (LAS) Supported
High-Speed Ethernet (HSE) Not Supported
Network Topologies Ring, Split, Redundant Trunk
Configuration Software Studio 5000 Logix Designer
Configuration Interface Add-On Profile (AOP)
Power Consumption 260 mA at 24V DC, without field devices
Power Dissipation 12.24 W at 24V DC
Isolation Voltage 30V Continuous
Isolation Test Voltage 500V DC for 60 Seconds
Enclosure Type Open-Style
Operating Temperature 0–60°C
Storage Temperature -40 to +85°C
Relative Humidity 5–95%, non-condensing
Dimensions 152 × 80 × 136 mm
Weight 0.54 kg

Product Features

  • EtherNet/IP-to-FOUNDATION Fieldbus Integration: Establishes a direct communication gateway between EtherNet/IP controllers and FOUNDATION Fieldbus H1 instrumentation.
  • Dual Ethernet Ports: Provides two Ethernet connections for integration into supported industrial network arrangements.
  • Dual H1 Hardware Ports: Offers two physical fieldbus connection points belonging to one logical H1 segment.
  • 16-Device Capacity: Supports up to 16 FOUNDATION Fieldbus devices on a single H1 segment.
  • Integrated Power Conditioning: Includes built-in fieldbus power conditioning, eliminating the need for an additional external conditioner.
  • 500 mA Port Capacity: Each H1 hardware port can provide up to 500 mA.
  • Multiple Network Topologies: Supports ring, split, and redundant trunk arrangements for different fieldbus installation requirements.
  • FOUNDATION Fieldbus Host Capability: Includes Link Active Scheduler functionality for coordinating fieldbus communication.
  • Studio 5000 Integration: Uses a dedicated Add-On Profile for configuring the linking device and its field instruments.
  • Field Device Integration: Allows process variables and field instrument information to be exchanged with Logix controllers.
  • Industrial Network Diagnostics: Supports communication monitoring and troubleshooting through the linking device’s diagnostic capabilities.

Product Working Principle

The 1788-EN2FFR operates as a communication gateway between EtherNet/IP and FOUNDATION Fieldbus H1. It manages the exchange of information between the controller-level Ethernet network and the field-level instrumentation network.

Its operation involves several stages.

1. EtherNet/IP Communication

The device connects to the EtherNet/IP network through its two Ethernet ports. It exchanges controller information and supports the selected Ethernet network topology.

2. FOUNDATION Fieldbus H1 Communication

On the fieldbus side, the two hardware ports provide physical connections to the H1 segment. Although there are two connection points, they belong to the same logical fieldbus segment rather than representing two independent H1 networks.

3. Process Data Exchange

The linking device manages communication between EtherNet/IP and H1. Process variables and field instrument information are made available to the Logix controller through the configured communication structure.

4. Fieldbus Power Conditioning

The integrated power conditioner supplies conditioned DC power to the H1 network. This prevents the digital communication signal from interfering with the DC power supply and eliminates the need for a separate external fieldbus conditioner in supported arrangements.

5. Communication Scheduling

The device includes Link Active Scheduler functionality. The LAS coordinates scheduled communication activities on the FOUNDATION Fieldbus segment, allowing connected instruments to exchange process information according to the configured communication schedule.

A simplified network arrangement is:

ControlLogix Controller → EtherNet/IP Network → 1788-EN2FFR → FOUNDATION Fieldbus H1 → Field Instruments

The 1788-EN2FFR supports H1 communication and does not provide a High-Speed Ethernet (HSE) interface.


Role in Allen-Bradley EtherNet/IP and FOUNDATION Fieldbus Control Architecture

Within an Allen-Bradley process automation system, the 1788-EN2FFR serves as the communication interface between EtherNet/IP-based controllers and FOUNDATION Fieldbus process instrumentation.

The EtherNet/IP network carries controller information, while the H1 network connects field-level devices such as pressure transmitters, temperature transmitters, flowmeters, and valve positioners.

The linking device allows these instruments to participate in the control architecture without requiring a separate H1-to-DP gateway.

System Component Function
1788-EN2FFR Connects EtherNet/IP with FOUNDATION Fieldbus H1
ControlLogix Controller Executes process control and automation logic
1756-EN2T Provides EtherNet/IP communication for ControlLogix systems
1756-EN2TR Provides two-port EtherNet/IP communication with DLR support
EtherNet/IP Network Transfers controller and process information
FOUNDATION Fieldbus H1 Cable Connects field instruments to the linking device
1788-FBJB4R Provides redundant FOUNDATION Fieldbus junction connections
1788-FBJB6 Provides multiple field instrument connections
FOUNDATION Fieldbus Transmitters Measure pressure, temperature, flow, and other process variables
FOUNDATION Fieldbus Positioners Receive valve positioning commands
24V DC Power Supply Supplies operating power to the linking device and H1 segment

Industrial Applications

The 1788-EN2FFR is suitable for process automation installations where FOUNDATION Fieldbus instruments need to communicate with EtherNet/IP-based control systems.

Industrial Application Typical Use
Oil and Gas Integrating FOUNDATION Fieldbus pressure and flow transmitters
Petrochemical Processing Connecting distributed process instrumentation
Chemical Manufacturing Collecting temperature, pressure, and flow measurements
Power Generation Integrating field instruments into plant control networks
Water Treatment Connecting process measurement and control equipment
Pharmaceutical Manufacturing Supporting communication with process instrumentation
Pulp and Paper Integrating fieldbus transmitters into distributed control systems
Food and Beverage Connecting process measurement and valve control instruments
Refining Operations Linking field instruments with centralized control systems
Industrial Utilities Supporting distributed process monitoring

Installation and Maintenance

  1. Verify the Model Number: Confirm that 1788-EN2FFR is the required EtherNet/IP to FOUNDATION Fieldbus H1 linking device.
  2. Check Power Requirements: Prepare a suitable 24–32V DC power supply capable of meeting the specified input requirements.
  3. Inspect the Device: Examine the Ethernet connectors, fieldbus terminals, power connections, and housing for visible damage.
  4. Prepare the Installation Location: Select a suitable control cabinet location with sufficient ventilation and access for field wiring.
  5. Mount the Linking Device: Install the unit according to the manufacturer’s mounting instructions.
  6. Connect EtherNet/IP Media: Connect the Ethernet cables to the designated ports and verify that the network topology matches the system design.
  7. Connect FOUNDATION Fieldbus Wiring: Connect the H1 segment to the appropriate hardware ports, observing the specified wiring and polarity requirements.
  8. Check Fieldbus Topology: Verify that the selected ring, split, or redundant trunk arrangement follows the fieldbus network design.
  9. Connect the DC Power Supply: Wire the external 24–32V DC supply to the designated terminals and verify the polarity before energizing the device.
  10. Configure the Linking Device: Use Studio 5000 Logix Designer and the dedicated Add-On Profile to configure the linking device and connected field instruments.
  11. Verify Network Communication: Check the Ethernet and fieldbus status indicators and confirm that the controller can communicate with the configured H1 devices.
  12. Perform Routine Inspection: Periodically inspect the Ethernet connections, fieldbus wiring, power terminals, grounding, and communication status for signs of deterioration or faults.

Compatible System Components

Component Function
Allen-Bradley 1788-EN2FFR EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device
Allen-Bradley 1788-CN2FFR ControlNet to FOUNDATION Fieldbus H1 Linking Device
Allen-Bradley 1788-FBJB4R 4-Way Redundant Intelligent Fieldbus Junction Box
Allen-Bradley 1788-FBJB6 6-Way Intelligent Fieldbus Junction Box
Allen-Bradley 1756-EN2T ControlLogix EtherNet/IP Bridge Module
Allen-Bradley 1756-EN2TR ControlLogix Two-Port EtherNet/IP Bridge Module
Allen-Bradley ControlLogix Controller Executes process control logic
FOUNDATION Fieldbus H1 Instruments Process measurement and control devices
24V DC Power Supply External operating power source

Recommended Related Models

Model Product Type Application
Allen-Bradley 1788-CN2FFR ControlNet to FOUNDATION Fieldbus H1 Linking Device ControlNet to FOUNDATION Fieldbus integration
Allen-Bradley 1788-EN2PAR EtherNet/IP to PROFIBUS-PA Linking Device EtherNet/IP to PROFIBUS-PA integration
Allen-Bradley 1788-CN2PAR ControlNet to PROFIBUS-PA Linking Device ControlNet to PROFIBUS-PA integration
Allen-Bradley 1788-FBJB4R 4-Way Redundant Intelligent Fieldbus Junction Box Redundant H1 field device connections
Allen-Bradley 1788-FBJB6 6-Way Intelligent Fieldbus Junction Box FOUNDATION Fieldbus device distribution
Allen-Bradley 1756-EN2TR ControlLogix Two-Port EtherNet/IP Bridge Module EtherNet/IP network connectivity

Key Advantages

  • Connects EtherNet/IP controllers with FOUNDATION Fieldbus H1 instruments.
  • Supports up to 16 field devices on one H1 segment.
  • Provides two physical H1 connection ports.
  • Includes integrated fieldbus power conditioning.
  • Supports multiple fieldbus media topologies.
  • Provides built-in Link Active Scheduler functionality.
  • Integrates with Studio 5000 Logix Designer.

Technical FAQs

1. How many FOUNDATION Fieldbus devices can the 1788-EN2FFR support?

The 1788-EN2FFR supports up to 16 field devices on a single FOUNDATION Fieldbus H1 segment. The actual number used should also account for cable length, device current consumption, and network design requirements.

2. Are the two H1 ports on the 1788-EN2FFR independent fieldbus networks?

No. The two hardware ports are divided connection points belonging to the same logical H1 segment. They should be treated as part of one fieldbus network when planning device connections and network topology.

3. Does the 1788-EN2FFR require an external FOUNDATION Fieldbus power conditioner?

No. The device incorporates built-in fieldbus power conditioning. A standard 24–32V DC power supply is used to power the linking device and the H1 segment.

4. What is the difference between 1788-EN2FFR and 1788-CN2FFR?

The 1788-EN2FFR connects an EtherNet/IP network to FOUNDATION Fieldbus H1, whereas the 1788-CN2FFR connects a ControlNet network to FOUNDATION Fieldbus H1. Both support up to 16 H1 field devices and include integrated fieldbus power conditioning, but their controller-side communication interfaces are different.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501