The Allen-Bradley 1786-FS20 is a preassembled fiber optic cable used in Allen-Bradley ControlNet communication networks. It provides a 20-meter optical connection between compatible fiber interfaces, particularly the 1786-RPFS short-distance fiber repeater.
Unlike conventional coaxial ControlNet cables, the 1786-FS20 transmits communication signals through optical fiber. This makes it useful when network connections need to cross electrically noisy areas, connect separate control cabinets, or link automation equipment installed in different sections of a production facility.
The cable uses 200-micron fiber and factory-installed V-pin connectors. These connectors match the Versalink V-System interface used by the short-distance fiber repeater arrangement. Because the assembly is preterminated, technicians do not need to perform connector installation at the job site.
A typical application involves connecting fiber repeater interfaces between two automation cabinets. For example, a PLC cabinet may communicate with a remote machine control panel through a fiber connection rather than extending the coaxial network directly through an electrically noisy production area.
The 20-meter cable length makes the 1786-FS20 suitable for installations where a 10-meter assembly is insufficient but a longer cable would introduce unnecessary routing slack. It belongs to the same ControlNet fiber cable family as the 1786-FS10, 1786-FS60, 1786-FS100, 1786-FS200, and 1786-FS300.
The 1786-FS20 is a passive transmission component. It carries optical signals between compatible interfaces but does not independently convert electrical signals, amplify communication signals, or manage network traffic. These functions are handled by the connected repeater hardware.
For maintenance engineers, connector cleanliness and cable handling are important considerations. Contamination at the fiber ends, excessive bending, or physical damage can increase optical loss and interrupt communication between network sections.
| Parameter | Specification |
|---|---|
| Manufacturer | Allen-Bradley |
| Brand | Rockwell Automation |
| Model | 1786-FS20 |
| Product Series | ControlNet |
| Product Type | ControlNet Fiber Optic Cable Assembly |
| Cable Assembly Type | Short-Distance Fiber Optic Cable |
| Fiber Type | 200/230 µm HCS (Hard-Clad Silica) |
| Fiber Termination Type | Versalink V-System |
| Connector Configuration | V-Pin Connectors |
| Cable Jacket | PVC |
| Maximum Pull Tension | 490 N |
| Cyclic Flexing | More Than 5,000 Cycles |
| Minimum Bend Radius | 25 mm |
| Operating Wavelength | 650 nm |
| Optical Power Budget | 4.2 dB |
| Operating Temperature | -20 to +80°C |
| Non-Operating Temperature | -40 to +80°C |
| Compatible Fiber Repeater | 1786-RPFS |
| Network Compatibility | Allen-Bradley ControlNet |
| Cable Application | Short-Distance Fiber Communication |
| Cable Length | 20 meters |
| Shipping Weight | 3 kg |
The 1786-FS20 carries ControlNet communication signals through an optical fiber path between compatible repeater interfaces.
In a conventional ControlNet coaxial network, electrical signals travel through the trunk cable between network devices. When an optical connection is required, a compatible repeater converts the electrical communication signals into optical signals before transmission through the fiber cable.
The 1786-FS20 carries these optical signals through its HCS fiber core. At the receiving end, the connected optical interface converts the signals back into electrical form for the next ControlNet network section.
A simplified communication path is:
ControlNet Coaxial Network → 1786-RPA → 1786-RPFS → 1786-FS20 → Remote Fiber Interface → ControlNet Network
The cable itself does not perform signal conversion. Its function is to maintain the optical transmission path between the connected devices.
The 200/230 µm HCS fiber construction is matched to the short-distance repeater architecture. Its V-pin connectors establish the optical connection with the corresponding Versalink interfaces.
The optical power budget is another important consideration. The specified 4.2 dB allowance represents the permitted total optical loss across the fiber link, including fiber attenuation, connectors, and other connection losses.
Mechanical handling also affects transmission performance. Excessive bending, pulling, or crushing can damage the fiber and increase attenuation. Maintaining the specified bend radius and protecting the connector ends help preserve communication quality.
The 1786-FS20 functions as the optical transmission link in an Allen-Bradley ControlNet fiber repeater arrangement. It connects compatible fiber modules and allows communication signals to pass between equipment areas without requiring a continuous electrical connection.
A mixed-media ControlNet installation may use coaxial trunk cables for the main network and fiber connections where electrical isolation or separation between equipment areas is required.
A typical arrangement is:
ControlNet Coaxial Trunk → Network Tap → 1786-RPA → 1786-RPFS → 1786-FS20 → Remote Fiber Interface → ControlNet Network
| System Component | Function |
|---|---|
| Allen-Bradley 1786-FS20 | Provides a 20-meter optical communication connection |
| 1786-RPA | Provides the modular repeater adapter interface |
| 1786-RPFS | Provides the short-distance fiber repeater interface |
| 1786-RG6 | Carries ControlNet communication through coaxial media |
| 1786-XT | Terminates the coaxial trunk segment |
| 1786-TPS | Provides a straight coaxial network tap |
| 1786-TPR | Provides a right-angle coaxial network tap |
| ControlNet Communication Modules | Connect PLC controllers to the ControlNet network |
| Remote I/O Adapters | Interface distributed I/O stations with the network |
| 24 V DC Power Supply | Supplies the modular repeater adapter |
The 1786-FS20 is particularly useful where a ControlNet installation requires a preassembled optical connection between compatible short-distance fiber interfaces.
The 1786-FS20 is suitable for industrial facilities that use ControlNet fiber repeaters to connect separated automation equipment or reduce the effects of electrical interference on communication links.
| Industrial Application | Typical Use |
|---|---|
| Automotive Manufacturing | Connecting fiber repeater interfaces between production-line control cabinets |
| Packaging Machinery | Establishing optical communication between machine enclosures |
| Steel Manufacturing | Connecting ControlNet network sections around motors and high-power electrical equipment |
| Power Generation | Linking control equipment across separate electrical rooms |
| Oil and Gas Automation | Providing optical connections between distributed control enclosures |
| Chemical Processing | Connecting network sections across process areas |
| Water Treatment | Linking remote control cabinets and distributed I/O stations |
| Material Handling | Establishing fiber connections between conveyor control areas |
| Industrial Drive Systems | Connecting compatible fiber interfaces in drive installations |
| General Manufacturing | Extending ControlNet communication between separated equipment areas |
During troubleshooting, inspect connector cleanliness and cable routing before replacing repeater modules. A contaminated optical interface or damaged fiber can interrupt communication even when the electronic modules are functioning normally.
| Component | Function |
|---|---|
| Allen-Bradley 1786-FS20 | 20-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS10 | 10-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS60 | 60-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS100 | 100-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS200 | 200-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS300 | 300-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FSB500 | 500-meter bulk ControlNet fiber cable |
| Allen-Bradley 1786-FSKIT | ControlNet fiber connector kit |
| Allen-Bradley 1786-RPFS | ControlNet short-distance fiber repeater |
| Allen-Bradley 1786-RPA | ControlNet modular repeater adapter |
| Allen-Bradley 1786-RG6 | ControlNet RG-6 coaxial trunk cable |
| Model / Product | Product Type | Typical Application |
|---|---|---|
| Allen-Bradley 1786-FS10 | ControlNet Fiber Optic Cable Assembly, 10 m | Shorter optical connections |
| Allen-Bradley 1786-FS60 | ControlNet Fiber Optic Cable Assembly, 60 m | Longer connections between repeater interfaces |
| Allen-Bradley 1786-FS100 | ControlNet Fiber Optic Cable Assembly, 100 m | Extended optical connections between control areas |
| Allen-Bradley 1786-FS200 | ControlNet Fiber Optic Cable Assembly, 200 m | Longer ControlNet fiber connections |
| Allen-Bradley 1786-RPFS | ControlNet Short-Distance Fiber Repeater | Connecting coaxial and fiber network sections |
| Allen-Bradley 1786-FSKIT | ControlNet Fiber Connector Kit | Preparing compatible bulk fiber cable connections |
Both models belong to the ControlNet short-distance fiber cable family and use 200-micron fiber with V-pin connectors. The main difference is cable length: the 1786-FS20 provides a 20-meter connection, while the 1786-FS10 provides a 10-meter connection.
The 1786-FS20 is intended for use with the Allen-Bradley 1786-RPFS short-distance fiber repeater. The repeater provides the optical interface required to connect the fiber cable to the ControlNet network architecture.
Yes. Optical fiber does not carry electrical communication signals through copper conductors, so the link is not directly affected by electromagnetic interference in the same way as conventional coaxial cabling. Appropriate cable routing and mechanical protection are still necessary.
Inspect both V-pin connector ends for contamination or incomplete connections. Then check the cable for excessive bending, kinks, or physical damage. If the cable is intact, verify the 1786-RPFS module status and confirm that the total optical link loss remains within the specified 4.2 dB power budget.