• Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module
  • Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module
  • Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module
  • Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module
Product Overview The Honeywell 2MLR-AC12 is a redundant power supply module for the MasterLogic-200R PLC system. It accepts an AC 110 V input and delivers a regulated 5 V DC output rated at 5.5 A. The m……
Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module
  • Honeywell
  • 2MLR-AC12
  • Redundant Power Supply Module
  • USA
  • 55 × 95 × 110 mm
  • 0.34 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell 2MLR-AC12 MasterLogic-200 Redundant Power Supply Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Honeywell 2MLR-AC12 is a redundant power supply module for the MasterLogic-200R PLC system. It accepts an AC 110 V input and delivers a regulated 5 V DC output rated at 5.5 A. The module is used in redundant controller configurations where maintaining power availability is essential to continuous PLC operation.

In a process control installation, an unexpected power supply failure can interrupt CPU operation, communication, and I/O processing. The 2MLR-AC12 is part of the ML200R redundant power architecture, allowing the system to use redundant power supply arrangements rather than depending on a single power source module.

The module converts incoming AC power into the regulated DC voltage required by the PLC system. Its 5.5 A output capacity supports the power requirements of the associated controller and installed system modules, subject to the total current consumption of the configuration.

The 2MLR-AC12 also incorporates a RUN contact relay output. This contact can be used as part of the external power status monitoring arrangement, allowing the control system to receive an indication associated with power module operation.

Typical applications include continuous process control, industrial production lines, utility control systems, and automation installations where an interruption to PLC power can affect equipment operation or process continuity.


Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 2MLR-AC12
Product Type Redundant Power Supply Module
Product Series MasterLogic-200R
Rated Input Voltage 110 VAC
Input Voltage Range 85–132 VAC
Input Frequency 50/60 Hz (47–63 Hz)
Maximum Input Power 110 VA / 42 W
Inrush Current 20 A peak or lower (within 8 ms)
Efficiency 65% or higher
Allowed Instantaneous Interruption Within 20 ms
Output Voltage 5 VDC (±2%)
Output Current 5.5 A
Output Power 27.5 W @ 55°C
Overcurrent Protection 6.0–13.0 A
Input Fuse Built-in, non-user-replaceable
AC Fuse Rating 250 V / 3.15 A, time-lag type
RUN Contact Output Relay Contact
Relay Rated Switching Voltage/Current 24 VDC, 0.5 A
Minimum Switching Load 5 VDC, 1 mA
Relay Response Time OFF-to-ON: 10 ms or less; ON-to-OFF: 12 ms or less
Voltage Status Indicator LED
Installation Position Power section of basic or expansion base
Dimensions 55 × 95 × 110 mm
Weight 0.34 kg

Product Features

1. Redundant Power Supply Configuration

The 2MLR-AC12 belongs to the MasterLogic-200R redundant power supply family. It is intended for installations where power supply redundancy is incorporated into the PLC system architecture to reduce the risk of interruption caused by an individual power module failure.

2. AC 110 V Input

The module operates with a rated AC 110 V input and accepts an input voltage range of 85–132 VAC. This makes it suitable for control installations using the corresponding AC power distribution arrangement.

3. Regulated 5 V DC Output

The 2MLR-AC12 converts incoming AC power into a regulated 5 V DC output with a tolerance of ±2%. This is the supply voltage required by the associated MasterLogic-200R system components.

4. 5.5 A Output Capacity

The module provides a rated output current of 5.5 A, with a corresponding output power of 27.5 W at 55°C. The actual power budget must account for the combined current consumption of the installed CPU and other modules.

5. Built-In Input Fuse

The power supply incorporates a built-in input fuse that is not user-replaceable. The AC input protection specification is 250 V / 3.15 A with a time-lag fuse characteristic.

6. Overcurrent Protection

The module includes overcurrent protection with a specified protection range of 6.0–13.0 A. This protection helps address abnormal output current conditions within the power supply circuit.

7. RUN Contact Relay Output

An integrated RUN contact provides a relay-based status interface. Its rated switching capacity is 24 VDC at 0.5 A, making it suitable for compatible external monitoring circuits.

8. Voltage Status LED

The voltage status indicator illuminates when the output voltage is normal. Maintenance personnel can use this indication during initial startup and routine power system inspections.

9. Short Interruption Tolerance

The specified allowable instantaneous input interruption is within 20 ms. This characteristic is relevant when evaluating the power quality and operating conditions of the PLC installation.

10. Basic and Expansion Base Installation

The module is installed in the power section of the applicable basic or expansion base, forming part of the MasterLogic-200R power distribution arrangement.


Working Principle

The 2MLR-AC12 receives AC 110 V from the external power distribution circuit and converts it into regulated 5 V DC for the MasterLogic-200R PLC system.

During normal operation, the input circuit processes the incoming AC supply, and the internal conversion stage produces the required DC output. The regulated voltage is then supplied to the associated PLC base and installed modules.

The module’s 5.5 A output rating determines the available current capacity. When configuring a redundant PLC system, engineers need to calculate the total power consumption of the CPU, communication interfaces, and other installed modules to ensure that the selected power arrangement meets the system requirements.

The redundant power architecture is intended to maintain system power availability if one power supply path encounters a fault. The CPU and associated redundant power arrangement monitor the relevant power failure status, allowing the system to respond to an abnormal power condition.

The integrated RUN contact provides an additional interface for external status monitoring. It can be incorporated into an appropriate control or alarm circuit so that power supply status is available for operational supervision.

Typical Power Operation Sequence:

  1. AC 110 V is supplied to the 2MLR-AC12 input.
  2. The internal power conversion circuit processes the incoming AC voltage.
  3. The module generates a regulated 5 V DC output.
  4. The output supplies the associated MasterLogic-200R system components.
  5. The voltage status LED indicates normal output voltage.
  6. The RUN contact provides a relay status interface for external monitoring.
  7. In a redundant configuration, the system monitors power supply conditions and responds to a detected power failure according to its redundancy architecture.

Role in MasterLogic-200R Control Architecture

Within the MasterLogic-200R architecture, the 2MLR-AC12 supplies the DC power required by the redundant PLC system. Its function is different from that of the CPU and I/O modules: it does not execute control logic or process field signals, but maintains the electrical supply required for these operations.

The ML200R platform uses dedicated redundant hardware configurations, including redundant CPU modules, power supplies, and associated base and expansion interfaces.

The 2MLR-AC12 is the 110 V AC, 5.5 A power supply option within this arrangement. Other power supply variants offer different input voltages or output current ratings.

Component Product Type Function
2MLR-AC12 Redundant Power Supply Module AC 110 V input, 5.5 A output
2MLR-AC22 Redundant Power Supply Module AC 220 V input, 5.5 A output
2MLR-AC13 Redundant Power Supply Module AC 110 V input, 8.5 A output
2MLR-AC23 Redundant Power Supply Module AC 220 V input, 8.5 A output
2MLR-DC42 Redundant DC Power Supply Module DC 24 V input, 7.5 A output
2MLR-CPUH/T Redundant CPU Module Twisted-pair communication configuration
2MLR-CPUH/F Redundant CPU Module Fiber-optic communication configuration
2MLR-M02P Main CPU Base Installation of main controller modules
2MLR-M06P Main CPU Base Six-module main base configuration
2MLR-E08P Expansion I/O Base Eight-module I/O expansion
2MLR-E12P Expansion I/O Base Twelve-module I/O expansion
2MLR-E12H Redundant Expansion I/O Base Expansion with redundant interface support
2MLR-DBST I/O Interface Module Twisted-pair communication
2MLR-DBSF I/O Interface Module Fiber-optic communication
2MLR-DBSH Hybrid I/O Interface Module Twisted-pair and fiber-optic communication

Industrial Applications

Application Typical Use
Continuous Process Control Maintaining PLC power in process automation installations
Chemical Processing Supporting redundant control system power arrangements
Oil and Gas Facilities Supplying power to redundant PLC control infrastructure
Power Generation Supporting controller power in plant automation systems
Water Treatment Plants Maintaining power availability for process control equipment
Industrial Production Lines Supporting continuous operation of PLC-based machinery
Utility Automation Powering redundant control system configurations
Centralized Control Rooms Supporting MasterLogic-200R controller installations

Installation and Maintenance

  1. Verify Module Identification: Confirm that the installed unit is 2MLR-AC12 and distinguish it from the AC 220 V and higher-current variants.
  2. Check Input Voltage: Ensure that the incoming supply is compatible with the rated AC 110 V input and the specified 85–132 VAC operating range.
  3. Inspect AC Input Wiring: Check the incoming power connections, terminal condition, and protective grounding arrangement before energizing the module.
  4. Review Power Consumption: Calculate the combined current requirements of the CPU and installed modules to confirm that the 5.5 A output capacity is sufficient.
  5. Verify Redundant Configuration: Confirm that the module is installed as part of the intended MasterLogic-200R redundant power arrangement.
  6. Check Base Compatibility: Install the power module in the designated power section of the applicable basic or expansion base.
  7. Inspect Input Protection: Check the external power protection arrangement and remember that the internal input fuse is not designed for user replacement.
  8. Monitor Output Voltage: Observe the voltage status LED during startup and confirm that the system receives its required DC supply.
  9. Check RUN Contact Wiring: Verify the external monitoring circuit and ensure that the relay contact remains within its specified switching ratings.
  10. Inspect Ventilation Conditions: Keep the installation area clear of obstructions and maintain the operating environment required by the PLC system.
  11. Investigate Power Abnormalities: If the output voltage is abnormal, inspect the AC input, system load, wiring, and protection conditions before replacing the module.
  12. Maintain Power System Records: Document module models, input voltage arrangements, output current calculations, and redundant power connections for future maintenance.

Compatible System Components

Model Product Description Application
2MLR-AC22 MasterLogic-200R Redundant Power Supply, AC 220 V / 5.5 A Alternative AC input configuration
2MLR-AC13 MasterLogic-200R Redundant Power Supply, AC 110 V / 8.5 A Higher-current AC 110 V supply
2MLR-AC23 MasterLogic-200R Redundant Power Supply, AC 220 V / 8.5 A Higher-current AC 220 V supply
2MLR-DC42 MasterLogic-200R Redundant Power Supply, DC 24 V / 7.5 A DC input power arrangement
2MLR-CPUH/T Redundant CPU Module, Twisted-Pair Interface Main PLC control processing
2MLR-CPUH/F Redundant CPU Module, Fiber-Optic Interface Redundant controller processing
2MLR-M06P Main CPU Base Main controller installation
2MLR-E12P Expansion I/O Base I/O system expansion
2MLR-E12H Redundant Expansion I/O Base Redundant expansion configuration
2MLR-DBST Twisted-Pair I/O Interface Module Remote I/O communication
2MLR-DBSF Fiber-Optic I/O Interface Module Fiber-optic I/O communication
2MLR-DBSH Hybrid I/O Interface Module Combined communication interface
2MLC-F201 Multimode Fiber-Optic Sync Cable Redundant system synchronization

Recommended Related Models

Model Product Description
2MLR-AC22 MasterLogic-200R Redundant Power Supply Module, AC 220 V / 5.5 A
2MLR-AC13 MasterLogic-200R Redundant Power Supply Module, AC 110 V / 8.5 A
2MLR-AC23 MasterLogic-200R Redundant Power Supply Module, AC 220 V / 8.5 A
2MLR-DC42 MasterLogic-200R Redundant Power Supply Module, DC 24 V / 7.5 A
2MLR-CPUH/T MasterLogic-200R Redundant CPU Module, Twisted-Pair Interface
2MLR-CPUH/F MasterLogic-200R Redundant CPU Module, Fiber-Optic Interface

Key Advantages

  • Redundant power supply functionality for the MasterLogic-200R platform.
  • Rated AC 110 V input.
  • Input voltage range of 85–132 VAC.
  • Regulated 5 V DC output.
  • Rated output current of 5.5 A.
  • Output power of 27.5 W at 55°C.
  • Built-in input fuse protection.
  • Integrated overcurrent protection.
  • RUN contact relay output for status monitoring.
  • Voltage status LED indication.
  • Allowable instantaneous input interruption within 20 ms.
  • Compatibility with the MasterLogic-200R redundant power architecture.

Technical FAQs

1. What is the difference between the 2MLR-AC12 and 2MLR-AC22?

Both modules provide a rated output current of 5.5 A and belong to the MasterLogic-200R redundant power supply family. The primary difference is their rated AC input voltage. The 2MLR-AC12 operates from AC 110 V, while the 2MLR-AC22 operates from AC 220 V.

2. Can the 2MLR-AC12 be used in a standard non-redundant MasterLogic-200 installation?

The 2MLR-AC12 belongs to the MasterLogic-200R redundant power supply family. It should be selected for the corresponding redundant system architecture rather than treated as a direct replacement for the standard 2MLP power supply modules.

3. What does the RUN contact output monitor?

The integrated RUN contact is a relay output associated with power module status. It is rated for 24 VDC at 0.5 A and can be incorporated into a compatible external monitoring or alarm circuit.

4. How should the 5.5 A output capacity be evaluated when selecting the module?

The total 5 V DC current consumption of the CPU and installed system modules must be calculated. The combined demand should remain within the module’s rated output capacity. For larger configurations, the 2MLR-AC13 or 2MLR-AC23 may be considered when their input voltage and system compatibility requirements are satisfied.



Related Products