Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Honeywell 2MLL-PMEB is a PROFIBUS-DP Master Module for the MasterLogic-200 PLC platform. It provides a fieldbus communication interface between the PLC controller and distributed PROFIBUS-DP slave devices, allowing process information and equipment status to be exchanged over an industrial network.
Unlike conventional I/O modules that acquire individual electrical signals, the 2MLL-PMEB manages communication with networked devices. These may include remote I/O stations, motor drives, distributed control equipment, and other compatible PROFIBUS-DP devices.
One of its defining characteristics is support for PROFIBUS-DP V1. This extends the communication capabilities beyond the cyclic data exchange associated with DP V0 by supporting asynchronous acyclic communication services. In applications involving intelligent field devices, this distinction is useful when additional device parameters, diagnostic information, or configuration data need to be accessed.
The module uses an RS-485 electrical interface and shielded twisted-pair cabling for PROFIBUS-DP communication. It also supports automatic baud-rate detection, reducing the amount of manual communication-speed configuration required during network integration.
For example, in a manufacturing plant with several distributed drive systems and remote I/O stations, the 2MLL-PMEB can coordinate communication between the MasterLogic-200 controller and the connected field devices. The PLC processes the received information and uses it to coordinate machine sequences, equipment interlocks, and operating conditions.
The PMEB should not be confused with the 2MLL-PMEA. Although both belong to the MasterLogic-200 PROFIBUS-DP communication family, their protocol versions and supported communication functions differ.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model | 2MLL-PMEB |
| Product Type | PROFIBUS-DP Master Module |
| Product Series | MasterLogic-200 |
| Communication Protocol | PROFIBUS-DP |
| Protocol Version | DP-V1 |
| Network Role | Master |
| Physical Interface | RS-485 Electrical |
| Transmission Medium | Shielded Twisted-Pair Cable |
| Communication Speed | 9.6 kbps to 12 Mbps |
| Baud Rate Detection | Automatic |
| Synchronization Functions | Sync / Freeze |
| Maximum Input Data | 244 Bytes per Slave |
| Maximum Output Data | 244 Bytes per Slave |
| Maximum Data Size | 10 kB per Master |
| Maximum Slave Data | 244 Bytes per Slave |
| Supported Network Services | Cyclic and Acyclic Communication |
| Dimensions | 120 × 25 × 110 mm |
| Weight | 0.116 kg |
1. PROFIBUS-DP V1 Master Functionality
The 2MLL-PMEB supports PROFIBUS-DP V1, allowing the MasterLogic-200 PLC to communicate with compatible slave devices through cyclic and acyclic data exchange. This is particularly useful when an application requires access to both operating data and additional device information.
2. RS-485 Electrical Interface
The module uses an RS-485 physical interface with shielded twisted-pair cabling. This provides the electrical communication connection required for PROFIBUS-DP fieldbus installations.
3. Automatic Baud Rate Detection
Automatic baud-rate detection helps the module identify the communication speed used by the network. This simplifies network commissioning when integrating compatible PROFIBUS-DP equipment.
4. Sync and Freeze Functions
The Sync and Freeze functions support coordinated data handling across participating slave devices. They are useful in applications where multiple distributed I/O stations need to update or maintain their data according to a coordinated control sequence.
5. High-Speed Communication
The module supports communication speeds from 9.6 kbps to 12 Mbps. The selected speed depends on the network configuration, cable characteristics, and connected equipment.
6. Distributed Data Exchange
The module supports up to 244 bytes of input data and 244 bytes of output data per slave. This allows compatible network devices to exchange substantial process information with the PLC.
7. Acyclic Device Communication
DP-V1 supports asynchronous communication services in addition to cyclic process-data exchange. This allows supported devices to provide additional parameter and diagnostic information when requested.
8. Multiple Module Installation
The MasterLogic-200 Pnet architecture supports installation of up to 12 Pnet interface modules, subject to CPU configuration and system restrictions. This allows communication capacity to be expanded in larger automation installations.
The 2MLL-PMEB operates as the master interface of a PROFIBUS-DP network. It manages communication with configured slave devices and exchanges their process information with the MasterLogic-200 CPU.
During network initialization, the master establishes communication with the configured slave stations. The communication system checks the participating devices and prepares the data exchange according to the network configuration.
During normal operation, cyclic communication transfers process information between the master and slave devices. Input information from remote I/O stations, for example, becomes available to the PLC application, while output information can be transmitted to the connected equipment.
DP-V1 adds acyclic communication capabilities. This allows supported devices to exchange additional information, such as parameter data and diagnostic details, without relying exclusively on the regular cyclic process-data exchange.
The module also supports Sync and Freeze functions. These can be used to coordinate the handling of data across multiple participating devices.
Typical Communication Path:
MasterLogic-200 CPU → 2MLL-PMEB → RS-485 PROFIBUS-DP Network → Slave Devices → Remote I/O / Drives / Field Equipment
Example Industrial Operation:
Within the MasterLogic-200 architecture, the 2MLL-PMEB serves as the PROFIBUS-DP master communication interface. Its role is different from that of local digital and analog I/O modules because it manages communication with distributed network devices rather than directly handling individual field wiring points.
The module is particularly useful when remote I/O stations, drives, and intelligent field devices are distributed across a production facility. Instead of bringing every individual signal back to the main PLC cabinet, equipment can exchange data through the PROFIBUS-DP network.
The MasterLogic-200 CPU remains responsible for application execution and control decisions. The PMEB manages the fieldbus communication, making the exchanged information available to the PLC application.
The following components belong to the broader MasterLogic-200 architecture. Individual hardware compatibility and supported communication services should be checked against the installed CPU configuration.
| Control System Component | Function |
|---|---|
| 2MLL-PMEB | PROFIBUS-DP V1 Master Communication Module |
| 2MLL-PMEA | PROFIBUS-DP V0 Master Module |
| 2MLL-PSEA | PROFIBUS-DP Slave Interface Module |
| 2MLL-PSRA | PROFIBUS-DP Remote Interface Module |
| 2MLL-DMEA | DeviceNet Master Module |
| 2MLL-C42A | RS-422/485 Serial Communication Module |
| 2MLL-EFMT | Fast Ethernet Electrical Communication Module |
| 2MLL-EFMF | Fast Ethernet Fiber-Optic Communication Module |
| 2MLI-CPUH | High Performance IEC CPU Module |
| 2MLI-CPUS | Standard IEC CPU Module |
| 2MLK-CPUH | High Performance Non-IEC CPU Module |
| 2MLK-CPUS | Standard Non-IEC CPU Module |
| 2MLP-ACF1 | Power Supply Module |
| 2MLP-ACF2 | Power Supply Module |
| 2MLB-M06A | Main CPU Base |
| 2MLB-E08A | Expansion I/O Base |
| Application | PROFIBUS-DP Communication Function |
|---|---|
| Automotive Manufacturing | Exchanges production equipment status and distributed I/O information |
| Packaging Machinery | Coordinates remote I/O stations and networked machine components |
| Conveyor Systems | Communicates with distributed drives and remote equipment |
| Process Automation | Transfers process information between PLCs and intelligent field devices |
| Water Treatment Plants | Connects remote monitoring and control equipment |
| Material Handling | Exchanges position, operating, and equipment status information |
| Motor Drive Systems | Supports communication with compatible PROFIBUS-DP drives |
| Distributed I/O Systems | Coordinates remote input and output data |
| Industrial Production Lines | Connects multiple automation stations through a common fieldbus |
| Component | Product Type | Application |
|---|---|---|
| 2MLL-PMEA | PROFIBUS-DP V0 Master Module | Cyclic PROFIBUS-DP communication |
| 2MLL-PSEA | PROFIBUS-DP Slave Interface Module | Slave-side PROFIBUS-DP communication |
| 2MLL-PSRA | PROFIBUS-DP Remote Interface Module | Remote PROFIBUS-DP communication |
| 2MLL-DMEA | DeviceNet Master Module | DeviceNet network integration |
| 2MLL-C22A | RS-232C Serial Communication Module | Serial equipment communication |
| 2MLL-C42A | RS-422/485 Serial Communication Module | Dual-channel serial communication |
| 2MLL-CH2A | Combined Serial Communication Module | RS-232C and RS-422/485 communication |
| 2MLL-EFMT | Fast Ethernet Communication Module | Electrical Ethernet connectivity |
| 2MLL-EFMF | Fast Ethernet Communication Module | Fiber-optic Ethernet connectivity |
| 2MLI-CPUH | High Performance CPU Module | Executes PLC application logic |
| 2MLI-CPUS | Standard CPU Module | Standard PLC processing |
| 2MLP-ACF1 | Power Supply Module | Supplies PLC operating power |
| 2MLP-ACF2 | Power Supply Module | Supplies PLC operating power |
| 2MLB-M06A | Main CPU Base | Houses CPU and associated modules |
| 2MLB-E08A | Expansion I/O Base | Supports additional I/O modules |
| Model | Product Description |
|---|---|
| 2MLL-PMEA | MasterLogic-200 PROFIBUS-DP V0 Master Module |
| 2MLL-PSEA | MasterLogic-200 PROFIBUS-DP Slave Interface Module |
| 2MLL-PSRA | MasterLogic-200 PROFIBUS-DP Remote Interface Module |
| 2MLL-DMEA | MasterLogic-200 DeviceNet Master Module |
| 2MLL-C42A | MasterLogic-200 Dual RS-422/485 Serial Communication Module |
| 2MLL-EFMT | MasterLogic-200 Fast Ethernet Electrical Communication Module |
The main difference is the supported PROFIBUS-DP version. The 2MLL-PMEA supports DP-V0, while the 2MLL-PMEB supports DP-V1. DP-V1 adds acyclic communication services for accessing additional device parameters and diagnostic information.
Yes, it can communicate with compatible PROFIBUS-DP slave devices, including supported motor drives. The drive must have a compatible PROFIBUS-DP interface, and its device configuration and data mapping must be included in the network setup.
The module supports up to 244 bytes of input data and 244 bytes of output data per slave. The documented maximum data size is 10 kB per master. Actual usable data capacity depends on the network configuration and connected slave devices.
Automatic baud-rate detection allows the module to identify the communication speed used by the PROFIBUS-DP network. This helps simplify network initialization, although the connected devices, cable installation, and overall network configuration must still meet the selected communication requirements.