The Schneider Electric TSXASZ200 is a two-channel analog output module designed for the Modicon TSX Micro automation platform. It converts digital control values from a compatible PLC system into analog electrical signals used to regulate industrial equipment, including variable frequency drives, control valves, and other process-control devices.
Analog output modules are essential in automation systems where equipment must respond to continuously adjustable commands rather than simple ON/OFF signals. For example, a PLC may calculate a required motor speed, valve position, or process setpoint and send the corresponding digital value to the output module. The module converts that value into a standardized analog signal for the receiving device.
The TSXASZ200 supports current outputs of 0–20 mA and 4–20 mA, as well as voltage outputs of ±10 V. This flexibility allows it to support different types of industrial control interfaces, provided that the receiving equipment is compatible with the selected signal range and electrical characteristics.
With two independent analog output channels, the module can provide command signals to two compatible devices or control points. Typical applications include motor-speed references, proportional valve commands, process setpoint transmission, and other applications requiring PLC-generated analog signals.
The module belongs to the legacy Modicon TSX Micro family. Schneider Electric lists the TSXASZ200 as discontinued, with no direct replacement specified. It may therefore be relevant to maintenance teams that need to keep existing TSX Micro installations operating or source compatible spare parts for established machinery.
Before purchasing or installing this module, users should verify the complete catalog number, PLC compatibility, output type, wiring arrangement, and software configuration. Similar-looking analog modules may support different signal types or belong to different PLC platforms.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Model | TSXASZ200 |
| Product Series | Modicon TSX Micro |
| Product Type | Analog Output Module |
| Number of Channels | 2 |
| Current Output Ranges | 0–20 mA, 4–20 mA |
| Voltage Output Range | ±10 V |
| Analog-to-Digital / Digital-to-Analog Conversion Specification | 11 bits plus sign for current output; 11 bits for ±10 V output |
| Current Consumption | 150 mA |
| Isolation Voltage | 1500 V AC |
| Current Output Load Specification | Manufacturer specifies ≤ 0.6 Ω |
| Voltage Output Load Specification | Manufacturer specifies ≥ 1 Ω |
| Output Protection | Open-circuit protection for current outputs |
| Product Dimensions Provided | 103.7 × 86 × 32 mm |
| Product Weight Provided | 0.15 kg |
| Platform | Compatible Modicon TSX Micro systems |
| Lifecycle Status | Discontinued |
| Direct Replacement | No direct replacement specified by the manufacturer |
Note: The dimensions and weight above are the supplied listing values. Confirm the exact hardware revision, terminal arrangement, and physical measurements before installation or shipment. The manufacturer’s published product data lists a net weight of approximately 0.2 kg.
The primary function of the TSXASZ200 is to convert PLC-generated digital values into analog signals that external equipment can use as control references.
The PLC calculates a control value based on its program, sensor inputs, operator commands, and process requirements. The output module converts the programmed value into an analog electrical output.
For example, a PLC may determine that a motor should operate at a particular percentage of its available speed range. The TSXASZ200 can produce a corresponding analog reference signal, provided that the drive is configured to accept the selected output type.
The receiving equipment interprets the signal according to its own configuration. Correct scaling must therefore be established in both the PLC program and the controlled device.
The module supports 0–20 mA and 4–20 mA current signals. These ranges are widely used in industrial control because they can represent process values over a defined range.
A 4–20 mA signal commonly uses 4 mA as the lower end of the measurement or command range and 20 mA as the upper end. The 4 mA starting point can also help distinguish a valid low-end signal from certain wiring or signal-loss conditions, although the actual fault-detection method depends on the receiving device and system design.
The module’s output load and wiring requirements must be checked against the manufacturer’s documentation before connecting field equipment.
The TSXASZ200 also supports a bipolar ±10 V output range. This allows the module to provide positive or negative analog control values to compatible equipment.
Voltage references may be used by drives, controllers, and other industrial devices that accept bipolar analog commands. The permitted input range, input impedance, signal common, and grounding arrangement should be confirmed before connecting the module.
Two output channels allow a compatible controller to issue separate analog commands to two devices or control points. For example, one channel may regulate a motor-speed reference while the other adjusts a proportional valve.
The actual independence, channel configuration, and signal assignment must be implemented according to the module’s documentation and the PLC program.
The manufacturer’s specifications identify open-circuit protection for current outputs and an isolation voltage of 1500 V AC. These characteristics contribute to the module’s electrical interface design.
Isolation ratings must not be interpreted as permission to disregard grounding, wiring, or installation rules. Correct system design remains necessary to protect the controller, module, connected equipment, and maintenance personnel.
The TSXASZ200 serves as the analog command interface between a compatible Modicon TSX Micro PLC and external control equipment. It does not independently determine process requirements; instead, it converts control values generated by the PLC into electrical signals.
The PLC executes the control logic and determines the required output based on programmed conditions. The TSXASZ200 translates the applicable digital value into the configured analog signal.
This arrangement allows the controller to regulate equipment continuously rather than relying solely on discrete switching outputs.
A compatible variable frequency drive may accept a current or voltage reference to determine motor speed. The PLC can calculate the desired speed, and the analog output module can transmit the corresponding reference.
The drive’s input type, signal scaling, minimum and maximum values, and control-source settings must match the PLC output configuration.
Proportional valves and compatible actuators may use analog command signals to regulate flow, pressure, position, or another process variable. The TSXASZ200 can provide these commands when the field device accepts the selected output range.
The module does not directly guarantee valve positioning accuracy. Final performance depends on the actuator, mechanical system, feedback arrangements, control logic, and calibration.
In industrial process systems, a PLC may send a setpoint to another controller or device through an analog interface. The TSXASZ200 can support such arrangements where the receiving equipment has a compatible input.
Engineers should document the signal range and engineering units so that a value such as 50% corresponds to the intended process condition.
A compatible drive can use an analog reference from the TSXASZ200 to adjust the speed of a motor-driven machine. This can be useful in conveyors, mixers, pumps, and auxiliary equipment where operating speed must change with process demand.
The drive input must be configured for the selected current or voltage range, and the PLC scaling must match the drive’s intended speed range.
Industrial systems may require adjustable valve openings to regulate fluid flow or pressure. Where a proportional valve controller accepts 4–20 mA, 0–20 mA, or ±10 V, the module may provide the required command signal.
Valve feedback and closed-loop regulation require suitable sensors and control logic; an analog output module alone does not provide a complete feedback-control system.
The module can transmit analog setpoints to compatible controllers, such as temperature, pressure, or flow-control equipment. This allows a PLC to coordinate several process stages using programmed operating values.
The process variable, signal range, and receiving device’s engineering-unit scaling must be defined carefully.
Some packaging and material-handling machines use analog commands for speed references, tension control, or auxiliary motion. The module may be used in an existing TSX Micro installation where its output characteristics match the connected equipment.
Where an application requires high-speed motion control, precise positioning, or specialized closed-loop performance, the module’s suitability must be evaluated against the complete system requirements.
The TSXASZ200 is particularly relevant to maintenance of legacy Modicon TSX Micro systems. Keeping the original controller and compatible I/O hardware may reduce the amount of immediate modification required for an existing machine.
However, spare-part availability and the long-term support status of the platform should be considered when planning maintenance budgets and future modernization.
Correct integration is essential for reliable analog signal transmission and predictable process behavior.
Before installation, confirm that the host controller and rack or expansion arrangement support the TSXASZ200. Check the applicable TSX Micro hardware documentation and the PLC configuration software.
Do not assume that the module can be installed in a different Modicon family simply because the product is manufactured by Schneider Electric.
Determine whether the receiving device requires 0–20 mA, 4–20 mA, or ±10 V. Confirm the module configuration and wiring instructions for the chosen range.
Using the wrong signal type may cause inaccurate control, unexpected device behavior, or possible equipment damage.
The PLC program must convert the desired process value into the numerical range expected by the module. The analog signal must then be interpreted correctly by the receiving equipment.
For instance, a 4–20 mA output may be scaled so that 4 mA represents the minimum command and 20 mA represents the maximum command. The exact engineering-unit mapping depends on the application.
Use the specified terminals and wiring arrangement. Follow the manufacturer’s requirements for conductor selection, shielding, grounding, and separation from power wiring.
Analog signals can be affected by electrical noise, grounding differences, and wiring errors. Proper installation practices help maintain signal stability.
The module’s specified output-load conditions must be respected. Check the input impedance or load characteristics of the receiving device and the total resistance of the signal circuit.
The manufacturer’s stated current and voltage output load specifications should be interpreted using the official wiring and technical documentation for the exact module.
After installation, verify each output channel independently. Confirm the selected signal range, PLC scaling, receiving-device response, and behavior at representative low, middle, and high command values.
Where the process permits, test loss-of-signal handling and relevant interlocks. Document the final configuration so that future maintenance personnel can reproduce the intended operation.
The TSXASZ200 must be used with compatible TSX Micro hardware and appropriately configured field devices.
| Component | Function | Compatibility Considerations |
|---|---|---|
| Modicon TSX Micro PLC | Executes the control program | Verify hardware support and software configuration |
| TSX Micro system expansion hardware | Provides the required installation arrangement | Check the specific controller and system architecture |
| Variable frequency drive | Uses an analog reference to regulate motor speed | Confirm current or voltage input range and scaling |
| Proportional valve controller | Converts analog commands into valve actuation | Match the input signal and process range |
| Process controller | Receives analog setpoints | Verify signal type and engineering-unit scaling |
| Analog signal cable | Carries output signals to field devices | Follow wiring, shielding, and grounding requirements |
| Control cabinet | Houses the PLC and associated equipment | Confirm space, environmental conditions, and service access |
| PLC programming software | Configures program logic and output scaling | Verify compatibility with the installed TSX Micro controller |
These are examples of components used in a complete automation installation. They are not necessarily supplied with the TSXASZ200 module.
Schneider Electric lists the TSXASZ200 as discontinued and states that it has no direct replacement. Any alternative should therefore be selected through a compatibility assessment rather than assuming that another analog output module can be substituted without changes.
| Alternative Approach | Considerations |
|---|---|
| Another TSXASZ200 unit | Often the most straightforward option for maintaining the existing configuration, subject to condition and hardware revision |
| Compatible TSX Micro analog output module | Verify channel count, signal ranges, resolution, installation arrangement, and PLC support |
| Another Modicon analog output module | May require different hardware, wiring, programming, or controller compatibility |
| Modern PLC and analog output module | Suitable for a planned modernization project but may require a wider system redesign |
| External signal-conditioning device | May address a specific interface mismatch, but must be engineered for the signal and application |
Before selecting an alternative, compare:
A modern module may offer improved diagnostics or broader functionality, but it should not be considered a direct replacement until the complete system has been checked.
The module provides two channels for independent analog command signals, helping an existing TSX Micro controller interface with multiple compatible devices.
Support for 0–20 mA, 4–20 mA, and ±10 V enables connection to a range of industrial equipment with matching analog inputs.
The module converts PLC-generated values into field-level commands, allowing a control program to coordinate motors, valves, and process equipment.
The published conversion specification helps engineers assess whether the module is appropriate for the signal requirements of a particular application.
For existing TSX Micro installations, a matching spare module may help maintain the original control architecture while avoiding an immediate full-system upgrade.
Current and voltage analog signals remain common interfaces in industrial control. Correctly configured, the module can support integration with compatible field devices.
The TSXASZ200 is a two-channel analog output module for the Modicon TSX Micro automation platform. It converts PLC digital values into current or voltage signals for compatible external equipment.
It supports 0–20 mA, 4–20 mA, and ±10 V outputs. The selected range must match the receiving device and the PLC program’s scaling.
The module has two analog output channels. Each channel can be used for a compatible command signal within the module’s supported configuration.
Yes, if the drive accepts a supported analog input range and the wiring and scaling are configured correctly. The drive must be configured to use the analog reference as its command source.
It may be used with a compatible valve controller that accepts one of the supported analog signal types. Check the valve controller’s input specifications and the required process range.
Schneider Electric lists the model as discontinued, with no direct replacement specified. Availability may depend on remaining inventory, refurbished stock, or specialist spare-parts suppliers.
Not automatically. The alternative must be checked for host-controller compatibility, signal ranges, channel count, wiring, conversion characteristics, and software requirements.
Confirm the complete catalog number, physical condition, terminal condition, product markings, and available test information. Also verify that the module matches the installed TSX Micro system.
The module and receiving device must use compatible signal types and scaling. A mismatch can lead to incorrect process commands or failure to achieve the expected operating range.
The supplied listing value is 0.15 kg. Schneider Electric’s published specification lists a net weight of approximately 0.2 kg, so the actual unit should be weighed if exact shipping or inventory data is required.
Because the TSXASZ200 is a discontinued component, procurement should begin by checking the full model number and the requirements of the installed TSX Micro system.
When sourcing a replacement, verify the module’s condition, terminal layout, output channel operation, supported signal ranges, and compatibility with the host PLC. For used or refurbished units, request clear photographs and available functional-test information.
During maintenance, document the PLC configuration, signal ranges, and scaling used for each output. If the module is replaced, verify the output response against the receiving devices before returning the system to normal operation.
For long-term planning, assess the availability of spare modules and the remaining support period for the legacy platform. If a modernization project is being considered, evaluate the required I/O functions, PLC program migration, field wiring, and commissioning effort before selecting a newer platform.
The Schneider Electric TSXASZ200 Modicon TSX Micro Analog Output Module provides two analog output channels supporting 0–20 mA, 4–20 mA, and ±10 V signals. It enables compatible PLC systems to transmit adjustable control commands to drives, valve controllers, and other industrial equipment.
The module is now discontinued, and Schneider Electric does not specify a direct replacement. For existing installations, accurate model identification, verification of output characteristics, and careful compatibility checks are essential when purchasing spare parts or planning a replacement.