• Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit
Product Overview The Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit is listed as a maintenance component for compatible Ingersoll Rand industrial air compressors. Thermostatic……
Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand
  • 47555212001 47552954001
  • Thermostatic Valve Maintenance Kit
  • USA
  • 180 × 120 × 80 mm
  • 1.0 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit is listed as a maintenance component for compatible Ingersoll Rand industrial air compressors. Thermostatic valve components play an important role in compressor temperature management by regulating lubricant flow according to operating temperature.

In oil-injected rotary screw air compressors, lubricant performs several functions, including lubrication, cooling, and sealing. Maintaining the appropriate oil temperature helps support stable compressor operation and reliable separation and circulation of the lubricant. A thermostatic valve helps control the flow path of the oil between the cooling circuit and the compressor system as operating conditions change.

The part number 47552954001 is associated with a thermostatic valve core in available product listings. However, the precise contents and compatibility of the complete maintenance kit should be confirmed against the compressor model and the supplier’s parts list before ordering.

This product is intended for maintenance and service applications rather than use as a standalone control device. Selecting the correct kit helps technicians maintain the original temperature-control arrangement and avoid compatibility problems during compressor servicing.

Technical Specifications

Parameter Specification
Brand Ingersoll Rand
Product Category Air Compressor Spare Parts
Product Name Thermostatic Valve Maintenance Kit
Listed Part Numbers 47555212001 / 47552954001
Component Type Thermostatic valve maintenance component
Primary Function Compressor lubricant temperature regulation
Application Compatible Ingersoll Rand air compressors
Dimensions Provided 180 × 120 × 80 mm
Weight Provided 1.0 kg
Installation Type Compressor maintenance or replacement
Compatibility Must be verified against compressor model and parts list

Note: The dimensions and weight are the supplied listing specifications. Confirm the actual kit contents and packaged dimensions with the supplier before purchase.

Function and Working Principle

1. Lubricant Temperature Regulation

During compressor operation, mechanical work and compression generate heat. The lubricant absorbs some of this heat and circulates through the system to support cooling and lubrication.

A thermostatic valve helps manage lubricant temperature by changing the flow path in response to temperature conditions. Depending on the compressor design, the valve may direct oil through the cooler or allow part of the flow to bypass the cooler when additional cooling is not yet required.

The specific operating temperature and valve behavior depend on the compressor model and the installed thermostatic element.

2. Supporting Stable Compressor Operation

Maintaining the correct lubricant temperature is important for compressor performance. Oil that is too hot may reduce lubrication effectiveness and increase thermal stress. Excessively low operating temperatures can also create problems, including moisture condensation under certain operating conditions.

A properly functioning thermostatic valve helps the compressor reach and maintain its intended operating temperature under changing loads and ambient conditions.

3. Maintaining Lubricant Circulation

The thermostatic valve is part of the compressor’s lubricant circulation system. Its operation affects how oil moves through the cooling circuit and back toward the compression mechanism.

A worn, sticking, or damaged valve component may interfere with normal temperature regulation. Maintenance or replacement should follow the compressor manufacturer’s service procedures.

4. Maintenance and Component Replacement

A thermostatic valve maintenance kit may provide components needed to service a valve assembly. The exact contents can vary by kit and compressor model.

Before installation, technicians should check the part numbers, seals, valve elements, and other supplied components against the applicable parts list. Do not assume that two related part numbers always represent an identical kit or interchangeable component.

Role in Industrial Air Compressor Systems

The thermostatic valve maintenance kit supports the temperature-control system of compatible industrial compressors. Its role is particularly relevant in equipment that operates for extended periods or under changing load conditions.

Oil Cooling Circuit

The thermostatic valve coordinates lubricant flow through the cooling circuit according to the compressor’s temperature-control design. Correct operation supports the intended relationship between oil circulation and heat rejection.

Compressor Reliability

A functioning temperature-control arrangement helps reduce the risk of operating outside the compressor’s intended thermal conditions. Routine inspection can identify leakage, sticking, or abnormal temperature behavior before it develops into a more serious maintenance issue.

Preventive Maintenance

Replacing worn valve components during scheduled servicing can help maintain the original system configuration. Maintenance intervals should be based on the compressor manufacturer’s recommendations, operating hours, environmental conditions, and observed equipment condition.

Industrial Applications

1. Oil-Injected Rotary Screw Air Compressors

Oil-injected rotary screw compressors use lubricant for cooling, sealing, and lubrication. A compatible thermostatic valve maintenance kit may be used when servicing the oil temperature-control circuit.

2. Manufacturing Facilities

Factories often rely on compressed air for pneumatic tools, automation equipment, material handling, and production machinery. Maintaining the compressor’s thermal management system helps support dependable compressed-air availability.

3. Continuous-Duty Compressor Installations

Compressor systems operating for long periods may experience sustained thermal loads. Regular inspection of the temperature-control circuit can help technicians identify abnormal oil temperatures and potential valve problems.

4. Industrial Maintenance Workshops

Maintenance teams may use thermostatic valve service components during scheduled overhauls or corrective maintenance. Correct part identification is essential to avoid installing a component that does not match the original valve assembly.

Installation and System Integration

1. Confirm Compressor Compatibility

Before ordering or installing the kit, identify the compressor’s complete model number, serial number, and applicable parts documentation. Verify whether both listed part numbers are required for the intended maintenance task or whether one identifies an individual component.

2. Prepare the Compressor

Shut down the compressor and isolate its energy sources according to the manufacturer’s service instructions. Allow hot components and lubricant to cool, and safely release residual pressure before opening the relevant system.

Never remove a valve assembly from a pressurized or hot compressor.

3. Inspect the Existing Valve

Check the thermostatic valve assembly for contamination, damaged sealing surfaces, leakage, wear, and restricted movement. Determine whether the fault is caused by the valve itself or by another part of the lubricant cooling circuit.

4. Install the Correct Components

Use only components confirmed for the specific compressor model. Follow the specified assembly orientation, seal installation method, tightening requirements, and cleanliness procedures.

Avoid introducing dirt or foreign material into the lubricant circuit during servicing.

5. Test After Maintenance

After reassembly, restore the system according to the manufacturer’s instructions. Check for lubricant leakage, abnormal temperature behavior, and other signs of incorrect installation.

Record the replacement part numbers and maintenance work in the equipment service history.

Compatible System Components

Component Function Maintenance Considerations
Thermostatic valve core Responds to temperature conditions and influences valve operation Confirm exact part number and valve design
Thermostatic valve body Directs lubricant through the appropriate flow path Inspect for wear, contamination, and leakage
Lubricant cooler Removes heat from circulating oil Check for restricted airflow or reduced cooling performance
Compressor lubricant Provides lubrication, cooling, and sealing Use the grade specified for the compressor
Oil filter Removes contaminants from the lubricant Replace according to the maintenance schedule
Oil separator Separates lubricant from compressed air Check condition and pressure-drop symptoms
Seals and O-rings Help prevent lubricant leakage Use the correct sizes and materials
Temperature monitoring components Provide operating temperature information Check sensor condition and readings where fitted

These components are examples of related compressor-system parts. They are not necessarily included in the maintenance kit.

Replacement and Compatibility Considerations

The part numbers 47555212001 and 47552954001 should be checked individually before purchasing. Available listings associate 47552954001 with a thermostatic valve core, but that does not establish that it is a complete maintenance kit or that it is universally interchangeable across compressor models.

When evaluating a replacement, confirm:

  • The compressor model and serial number.
  • The original thermostatic valve part number.
  • The exact contents of the maintenance kit.
  • The valve design and temperature-control requirements.
  • The required seals and installation hardware.
  • The supplier’s compatibility confirmation.

A similar-looking thermostatic valve component may have a different temperature response, physical connection, or intended application. Use the compressor’s parts documentation to establish compatibility rather than relying on appearance alone.

Key Advantages

Temperature-Control System Maintenance

A correctly matched maintenance kit can support servicing of the compressor’s lubricant temperature-control arrangement.

Support for Stable Operation

Maintaining the thermostatic valve helps the compressor regulate lubricant flow according to its intended operating conditions.

Reduced Risk of Incorrect Replacement

Verifying the part numbers and kit contents before installation helps reduce the risk of ordering an incompatible component.

Preventive Maintenance Support

Replacing worn or damaged components as part of scheduled service can help reduce unexpected maintenance interruptions.

Industrial Spare-Part Identification

Retaining the original part number and compressor identification makes future procurement and service planning more straightforward.

Technical FAQs

1. What is the Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit?

It is listed as a thermostatic valve maintenance product for compatible Ingersoll Rand compressor equipment. Confirm the exact kit contents and application before purchase.

2. What does a thermostatic valve do in an air compressor?

It helps regulate lubricant flow through the cooling circuit according to temperature conditions, supporting the compressor’s intended oil-temperature range.

3. Is 47552954001 a complete maintenance kit?

Available product listings identify 47552954001 as a thermostatic valve core. Whether it is supplied as part of a complete kit depends on the product listing and supplier’s bill of materials.

4. Can this kit fit every Ingersoll Rand compressor?

No universal compatibility should be assumed. Confirm the compressor model, serial number, and parts documentation before ordering.

5. What are the listed dimensions and weight?

The supplied listing values are 180 × 120 × 80 mm and 1.0 kg. Confirm whether these measurements refer to the component or the packaged kit.

6. When should the thermostatic valve be inspected?

Inspection should follow the compressor manufacturer’s maintenance schedule. Abnormal lubricant temperatures, leakage, or suspected restricted valve movement may also justify troubleshooting.

7. Can a faulty thermostatic valve affect compressor performance?

Yes. If the valve does not regulate lubricant flow correctly, the compressor may experience abnormal oil-temperature behavior. Other cooling-system faults can produce similar symptoms, so diagnosis should consider the complete circuit.

8. What should buyers check before purchasing?

Verify both part numbers, the compressor model, kit contents, component condition, and supplier compatibility information. For critical equipment, confirm the applicable return and warranty terms.

Procurement and Maintenance Recommendations

When sourcing the Ingersoll Rand 47555212001 / 47552954001 thermostatic valve maintenance components, begin by checking the compressor’s model and serial number. Compare the original component number with the replacement listing and request a parts breakdown if the listing includes multiple numbers.

For industrial maintenance teams, keeping records of installed part numbers, replacement dates, operating hours, and observed oil temperatures can make future troubleshooting more efficient.

Store replacement components in clean, dry conditions and keep seals protected from contamination. During installation, follow the manufacturer’s procedures and use the lubricant and sealing materials specified for the compressor.

Conclusion

The Ingersoll Rand 47555212001 47552954001 Thermostatic Valve Maintenance Kit is associated with the temperature-control maintenance needs of compatible industrial air compressors. Thermostatic valve components help regulate lubricant flow through the cooling circuit and support stable compressor operating temperatures.

For successful procurement and maintenance, confirm the exact compressor application and the contents associated with each part number. Correct identification, careful installation, and appropriate post-maintenance testing help maintain the reliability of the compressor’s lubricant temperature-control system.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501