Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Honeywell 2MLC-E301 MasterLogic-200 Extension Cable connects compatible I/O expansion hardware in the MasterLogic-200 programmable logic controller (PLC) system. It is intended for installations that use a main CPU base and one or more expansion bases to accommodate the I/O modules required by the machine or process.
In a control cabinet, the CPU and main base may be positioned separately from an expansion base containing additional digital or analog I/O modules. The 2MLC-E301 provides the dedicated interconnection between compatible hardware, allowing the PLC system to accommodate a wider cabinet layout without relocating all modules to the main base.
The 3-meter cable length is useful when shorter expansion cables cannot reach the intended connection points along the planned routing path. It gives control-panel designers more room to arrange expansion hardware while keeping the complete cable route within the system’s permitted expansion distance.
For example, a manufacturing line may use the main PLC base for sequence control and an expansion base for additional sensor signals, valve feedback, and motor-status inputs. The 2MLC-E301 can connect the expansion hardware when the required route and system configuration are compatible.
The cable is a dedicated expansion accessory rather than a general-purpose communication lead. Its model number and connection requirements should be checked against the installed MasterLogic-200 hardware before replacement or system extension.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model / Part Number | 2MLC-E301 |
| Product Family | MasterLogic-200 |
| Product Type | Expansion I/O Cable |
| Cable Length | 3.0 meters |
| Weight | 0.39 kg |
The 2MLC-E301 establishes the physical connection between compatible MasterLogic-200 expansion components. It carries the signals required for the connected expansion hardware to participate in the supported PLC architecture.
A typical arrangement follows this path:
MasterLogic-200 CPU and Main Base → 2MLC-E301 Extension Cable → I/O Expansion Base → Installed I/O Modules
The CPU executes the control program, while the I/O modules acquire field signals or provide control outputs. The expansion cable connects the additional base to the system so that its installed modules can be used by the PLC application.
Consider a conveyor installation where the main base handles the machine sequence and an expansion base collects additional photoelectric sensor signals and motor feedback. The cable connects the designated hardware, allowing the controller to incorporate those signals into its programmed logic.
The total cable route is an important design consideration. For the applicable MasterLogic-200 expansion arrangement, the distance between the CPU and the farthest I/O expansion base must not exceed 15 meters. The selected cable length should therefore be assessed together with the other connections in the complete expansion system.
The 2MLC-E301 does not execute control logic, convert analog signals, or operate as an independent network switch. Its function is to establish the required physical interconnection between compatible expansion components.
The 2MLC-E301 occupies the interconnection layer between the main PLC hardware and an expansion base. It allows additional I/O capacity to be incorporated into a compatible system while accommodating the intended cabinet layout.
PLC CPU and Main Base → Expansion Cable → Expansion Base → Digital and Analog I/O Modules
| System Component | Function |
|---|---|
| Honeywell 2MLC-E301 | Connects compatible expansion-system hardware |
| MasterLogic-200 CPU | Executes the PLC program and coordinates system operation |
| Main CPU Base | Hosts the CPU and supported main-base modules |
| I/O Expansion Base | Provides additional positions for I/O modules |
| Digital Input Modules | Acquire discrete signals from sensors and switches |
| Digital Output Modules | Control compatible field devices through designated output circuits |
| Analog Input Modules | Acquire supported process measurements |
| Analog Output Modules | Supply configured analog control signals |
| Field Devices | Provide sensor feedback or receive control commands |
| Control Cabinet | Houses the PLC bases, modules, and associated wiring |
| Application | Typical Use |
|---|---|
| Packaging Machinery | Connecting expansion bases for additional sensors and actuators |
| Conveyor Systems | Extending I/O capacity for motor feedback and position switches |
| Assembly Lines | Linking expansion bases serving separate machine stations |
| Material Handling | Connecting expansion hardware for equipment status and interlocks |
| Process Control Panels | Extending the PLC’s field-signal capacity |
| Water Treatment Systems | Connecting additional I/O for pumps, valves, and instrumentation |
| Manufacturing Equipment | Incorporating extra control points into an existing PLC arrangement |
| Industrial Utility Systems | Connecting compatible expansion bases in utility-control cabinets |
| Machine-Building Projects | Accommodating expansion hardware within the planned cabinet layout |
| PLC Retrofit Projects | Reconnecting expansion hardware during control-panel modifications |
| Component | Function |
|---|---|
| Honeywell MasterLogic-200 CPU | Executes the PLC application |
| Honeywell MasterLogic-200 Main Base | Hosts the CPU and supported main-base modules |
| Honeywell MasterLogic-200 Expansion Base | Provides additional I/O module positions |
| Digital Input Modules | Acquire discrete field signals |
| Digital Output Modules | Provide discrete control outputs |
| Analog Input Modules | Acquire process-variable signals |
| Analog Output Modules | Supply analog commands to compatible field devices |
| Control Cabinet Wiring | Connects the PLC system to field equipment |
| Honeywell 2MLC-E301 | Provides the 3-meter expansion connection |
| Model | Product Type | Cable Length |
|---|---|---|
| Honeywell 2MLC-E041 | MasterLogic-200 Expansion I/O Cable | 0.4 m |
| Honeywell 2MLC-E061 | MasterLogic-200 Expansion I/O Cable | 0.6 m |
| Honeywell 2MLC-E121 | MasterLogic-200 Expansion I/O Cable | 1.2 m |
| Honeywell 2MLC-E301 | MasterLogic-200 Expansion I/O Cable | 3.0 m |
| Honeywell 2MLC-E501 | MasterLogic-200 Expansion I/O Cable | 5.0 m |
| Honeywell 2MLC-E102 | MasterLogic-200 Expansion I/O Cable | 10.0 m |
| Honeywell 2MLC-E152 | MasterLogic-200 Expansion I/O Cable | 15.0 m |
The cable is specified for the expansion I/O arrangement associated with the 2MLI-CPUU configuration. Verify the installed CPU and base arrangement before using it in a replacement or expansion project.
The 2MLC-E301 has a cable length of 3.0 meters, while the 2MLC-E501 is 5.0 meters long. Select the shortest suitable option that accommodates the intended route and complies with the system’s total expansion-distance limit.
The system supports expansion-cable options of different lengths. The complete arrangement must follow the supported base configuration, and the total distance between the CPU and the farthest I/O expansion base must remain within the specified 15-meter limit.
Inspect the cable for connector damage and confirm that both ends are correctly seated. Check the CPU and expansion-base compatibility, installed module configuration, and PLC expansion status before replacing the cable.