Product Overview The Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching is identified as a generator synchronization device intended to coordinate the electrical conditions of an incoming……
Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching
  • Woodward
  • CSC3BUERADAP
  • SPM-A Synchronizer with 1% Voltage Matching
  • USA
  • 120 × 100 × 60 mm
  • 1.2 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching is identified as a generator synchronization device intended to coordinate the electrical conditions of an incoming generator with an energized bus. Its primary role is to match frequency and phase angle and, with its voltage-matching function, help bring generator voltage into the required relationship with the bus before the generator circuit breaker closes.

In a power-generation installation, a generator cannot be connected to an energized bus solely because its frequency appears correct. The phase relationship and voltage difference must also fall within the limits established for the installation. If these conditions are not satisfied, closing the breaker can produce substantial electrical and mechanical transients. The synchronizer coordinates the adjustments needed to prepare the incoming generator for connection.

The SPM-A synchronization principle uses speed-bias signals to influence a compatible governor and voltage-correction signals to interface with a suitable voltage regulator. The governor adjusts prime-mover speed, while the excitation-control system adjusts generator voltage. The synchronizer evaluates the resulting electrical conditions and provides a breaker-close command when the configured synchronization requirements are met.

The 1% voltage-matching designation distinguishes this configuration from SPM-A versions without automatic voltage matching or models with different voltage-matching specifications. The exact CSC3BUERADAP ordering reference should be retained when identifying the required replacement, particularly when the installed system uses a specific output arrangement or customized assembly designation.

The synchronizer is one component of the complete generator-paralleling system. Correct operation depends on compatible voltage-sensing circuits, the governor, excitation controls, the breaker-control circuit, and the required protective interlocks.


Technical Specifications

Parameter Specification
Manufacturer Woodward
Model / Part Number CSC3BUERADAP
Product Family SPM-A
Product Type Synchronizer with 1% Voltage Matching
Primary Function Generator frequency, phase, and voltage matching
Voltage-Matching Specification 1%
Operating Frequency 50/60 Hz for the corresponding standard SPM-A configuration
Generator and Bus Voltage Inputs 115 or 230 V AC RMS for the corresponding standard SPM-A configuration
Phase-Matching Function Automatic phase and frequency matching
Breaker-Close Output Normally open relay contact on the standard SPM-A configuration
Operating Modes RUN, CHECK, PERMISSIVE, OFF on the standard SPM-A configuration
Power Consumption Maximum 5 W on the standard SPM-A configuration
Dimensions 120 × 100 × 60 mm
Weight 1.2 kg

Product Features

  • Automatic frequency matching: Sends speed-adjustment signals to a compatible governor to reduce the frequency difference between the incoming generator and the energized bus.
  • Phase-angle synchronization: Coordinates speed correction so the incoming generator approaches the configured phase-matching window.
  • 1% voltage matching: Supports voltage correction through a compatible excitation or voltage-regulation system.
  • Automatic breaker-close command: Provides the synchronization-related closing signal when the configured conditions are satisfied.
  • Selectable operating modes: The standard SPM-A platform supports RUN, CHECK, PERMISSIVE, and OFF for operating and testing requirements.
  • Adjustable synchronization dynamics: Allows the control response to be matched to the behavior of the connected prime mover and governing system.
  • Governor interface options: The SPM-A platform supports different output arrangements for compatible Woodward speed and load-sharing controls.
  • Generator-paralleling integration: Coordinates electrical matching with the surrounding generator control and breaker circuits.

Working Principle

The synchronizer compares voltage signals from the incoming generator and the energized bus. These signals allow the device to evaluate the frequency difference, phase relationship, and voltage mismatch before connection.

A typical synchronization sequence follows this path:

Incoming Generator and Energized Bus → Voltage-Sensing Circuits → SPM-A Synchronizer → Governor and Voltage Regulator → Breaker-Close Circuit

When the incoming generator frequency differs from the bus frequency, the synchronizer sends a speed-bias signal to the compatible governor. The governor adjusts the prime mover’s speed, changing the generator frequency and influencing the rate at which the phase angle moves toward the required closing position.

Voltage matching operates through a separate control path. If the generator voltage differs from the bus voltage, the synchronizer provides a correction signal to the compatible voltage regulator or excitation-control circuit. The regulator adjusts generator excitation to bring the voltage toward the required matching condition.

The 1% voltage-matching specification describes the matching capability of the designated SPM-A configuration. Actual performance depends on the associated regulator, sensing accuracy, wiring, and system adjustment.

Once the configured synchronization conditions are satisfied, the synchronizer can issue a breaker-close command. The command must be coordinated with the circuit breaker’s mechanical operating time and the external closing circuit so that the generator is connected within the permitted synchronizing window.

The standard SPM-A platform provides several operating modes. RUN supports automatic synchronization and breaker closure; CHECK allows synchronization behavior to be evaluated without normal breaker closure; PERMISSIVE checks synchronization conditions without normal speed trimming or voltage matching; and OFF disables the synchronizing function.

The synchronizer does not independently control prime-mover speed or generator excitation. Those functions remain with the connected governor and voltage regulator. Generator protection and any required independent synchronism-check functions must also be provided as part of the complete installation.


Role in the Generator Synchronization Architecture

The CSC3BUERADAP SPM-A synchronizer occupies the coordination layer between generator electrical measurements and the external control equipment responsible for speed, excitation, and breaker operation.

Generator and Bus Voltage Measurements → Synchronizer → Governor and Voltage Regulator → Breaker-Close Circuit

System Component Function
Woodward CSC3BUERADAP Coordinates generator frequency, phase, and voltage matching
Incoming Generator Supplies the electrical source to be synchronized
Energized Bus Provides the electrical reference for matching
Generator Voltage-Sensing Circuit Supplies the incoming generator voltage signal
Bus Voltage-Sensing Circuit Supplies the bus voltage reference
Governor or Load-Sharing Control Adjusts prime-mover speed in response to synchronizer commands
Automatic Voltage Regulator Controls generator excitation and voltage
Breaker-Close Relay Provides the synchronization-related closing command
Generator Circuit Breaker Connects the incoming generator to the bus
Synchronism-Check Relay Provides additional closing supervision where required
Generator Protection System Detects electrical faults and initiates protective action

Industrial Applications

Application Typical Use
Diesel Generator Plants Matching incoming generator frequency, phase, and voltage before paralleling
Gas Engine Power Stations Coordinating governor and excitation adjustments during synchronization
Steam-Turbine Generator Sets Preparing turbine-driven generators for connection to an energized bus
Standby Power Systems Synchronizing additional generating capacity where parallel operation is required
Industrial Power Plants Connecting generators to a common electrical bus
Combined Heat and Power Facilities Coordinating generator entry into an existing plant power system
Remote Power Stations Synchronizing generators in isolated or local power networks
Multiple Generator Installations Bringing individual generating units online under coordinated control
Industrial Utility Systems Integrating synchronization into generator switchgear
Generator Retrofit Projects Replacing an existing synchronizer while preserving the required control interfaces

Installation and Maintenance

  1. Verify the model reference: Confirm CSC3BUERADAP against the installed unit and equipment identification records before selecting a replacement.
  2. Check the voltage-matching requirement: Verify that the application requires 1% voltage matching and that the installed voltage regulator supports the corresponding control arrangement.
  3. Inspect generator and bus sensing: Check the voltage-sensing circuits, phase connections, and wiring polarity against the electrical drawings.
  4. Verify the input configuration: Ensure that the generator and bus voltage signals match the installed synchronizer’s specified input arrangement.
  5. Check governor compatibility: Confirm that the synchronizer output arrangement is suitable for the connected governor or load-sharing control.
  6. Inspect the excitation interface: Verify the voltage-correction connections and ensure that the voltage regulator responds in the correct direction.
  7. Check the breaker-close circuit: Inspect relay wiring, contact loading, external interlocks, and the breaker operating circuit.
  8. Review operating-mode wiring: Check the mode selector and verify that the selected operating mode matches the intended commissioning or operating procedure.
  9. Inspect panel connections: Check terminal security, cable condition, grounding, and separation between sensing and power wiring.
  10. Test synchronization without closure: Use the applicable test mode to evaluate frequency correction, phase matching, and voltage matching without permitting an unintended breaker-close operation.
  11. Validate the complete sequence: Under an approved commissioning procedure, verify governor response, voltage correction, synchronizing conditions, and breaker-close coordination.
  12. Record the configuration: Document the model reference, input arrangement, governor interface, voltage-matching settings, operating mode, and commissioning results.

Compatible System Components

Component Function
Woodward CSC3BUERADAP Provides the specified SPM-A synchronization function
Compatible SPM-A Voltage-Matching Configuration Supports generator voltage correction during synchronization
Woodward 2301 Load-Sharing Control Supports compatible high-impedance synchronizer output arrangements
Woodward 2301A Load-Sharing and Speed Control Supports compatible low-impedance output arrangements
Woodward Electrically Powered Governor (EPG) Controls prime-mover speed in supported configurations
Automatic Voltage Regulator Adjusts generator excitation and voltage
Generator Voltage-Sensing Circuit Supplies generator voltage measurements
Bus Voltage-Sensing Circuit Supplies the reference voltage measurements
Generator Circuit Breaker Connects the incoming generator to the energized bus
Breaker-Control Circuit Processes the synchronizer’s closing command
Synchronism-Check Relay Provides additional closing supervision where required
Generator Protection Equipment Provides electrical fault protection and required interlocks

Recommended Related Models

Model Product Type Selection Consideration
Woodward CSC3BUERADAP SPM-A Synchronizer with 1% Voltage Matching Reference model; preserve the complete ordering designation when replacing the installed unit
Woodward 9907-029 SPM-A Synchronizer with 1% Voltage Matching Standard SPM-A reference for 50/60 Hz operation with a ±10° phase window
Woodward 9905-005 SPM-A Synchronizer with 1% Voltage Matching Standard configuration with a ±5° phase window
Woodward 9905-001 SPM-A Synchronizer without Voltage Matching Alternative for systems where voltage matching is handled separately
Woodward 9905-003 SPM-A Synchronizer with 5% Voltage Matching Alternative voltage-matching specification
Woodward 9905-006 SPM-A Synchronizer with 0.5% Voltage Matching Alternative with a different voltage-matching specification
Woodward 9905-009 SPM-A Synchronizer with 10% Voltage Matching Alternative voltage-matching specification for suitable applications

Key Advantages

  • Coordinates generator frequency and phase before paralleling.
  • Supports a specified 1% voltage-matching function.
  • Provides a synchronization-related breaker-close command.
  • Works with compatible governor and excitation-control arrangements.
  • Supports testing and operating modes on the standard SPM-A platform.
  • Helps coordinate generator connection with the surrounding control and protection circuits.

Technical FAQs

Why is 1% voltage matching important for the CSC3BUERADAP?

Voltage matching helps reduce the difference between incoming generator voltage and bus voltage before the circuit breaker closes. The specified 1% matching capability identifies the intended configuration, while actual performance depends on the regulator and measurement circuit.

How does the synchronizer correct a generator that is running at the wrong frequency?

It sends a speed-bias command to a compatible governor. The governor changes prime-mover speed, adjusting generator frequency and moving the phase relationship toward the configured synchronization window.

What is the difference between CHECK and PERMISSIVE operation on the SPM-A platform?

CHECK is used to evaluate synchronization behavior without normal breaker closure. PERMISSIVE checks whether synchronization conditions are acceptable without normal speed trimming or voltage matching. The external mode wiring and breaker-control logic must implement the intended behavior correctly.

Can the CSC3BUERADAP be replaced directly with a 9907-029?

Do not assume direct interchangeability from the shared SPM-A designation and 1% voltage-matching function alone. Compare the complete ordering reference, phase window, output arrangement, connections, and physical installation requirements before substitution.