Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Woodward 9905-973 LINKnet 8-Channel Relay Output Module is a distributed digital output module used in compatible Woodward control systems. It provides eight relay output channels, allowing a controller to operate external devices through discrete switching signals rather than requiring every field connection to return directly to the main control cabinet.
In a turbine or engine control installation, the controller may need to operate auxiliary solenoid valves, signal external alarms, or switch interlock circuits as operating conditions change. The 9905-973 receives output commands through the LINKnet communication network and converts them into relay contact states for connected field circuits.
The module is part of Woodward’s LINKnet I/O family and is identified as the eight-channel relay output variant. It can be integrated into compatible control architectures, including systems using Woodward 723-series controls. Its function is distinct from that of a central controller: the controller executes the governing logic, while the relay module provides the physical switching interfaces needed to operate external equipment.
For maintenance engineers, the main selection considerations are the number of required relay outputs, contact ratings, network compatibility, and the electrical characteristics of the connected loads. The module must be installed and configured as part of a compatible LINKnet system rather than treated as a standalone programmable controller.
| Parameter | Specification |
|---|---|
| Manufacturer | Woodward |
| Model / Part Number | 9905-973 |
| Product Family | LINKnet |
| Product Type | 8-Channel Relay Output Module |
| Number of Output Channels | 8 |
| Output Type | Relay contacts |
| Communication Interface | LINKnet |
| Compatible Control Architecture | Compatible Woodward control systems |
| Typical Controller Integration | Woodward 723-series systems, subject to configuration |
| Primary Function | Switching external field circuits through relay outputs |
| Mounting | DIN rail, according to the installation arrangement |
| Dimensions | 87.5 × 146.25 × 53.75 mm |
| Weight | 1.13 kg |
The 9905-973 receives digital output commands from a compatible Woodward controller over the LINKnet communication network. Based on the commands and module configuration, its relay channels change state to open or close the associated field circuits.
A typical control path is:
Woodward Controller → LINKnet Network → 9905-973 Relay Output Module → Field Devices
For example, when a controller’s operating logic calls for an auxiliary solenoid valve to energize, it sends the corresponding output command through LINKnet. The module switches the assigned relay contact, allowing the external circuit to operate the valve if the wiring and electrical ratings are appropriate.
The same arrangement can be used for alarm annunciation, permissive signals, and other discrete control functions. Each channel must be wired according to its intended circuit, including the required common, normally open, or normally closed contact arrangement where applicable.
The relay module does not independently determine when a valve or alarm should operate. The host controller supplies the logic and commands, while the module provides the physical switching function. Correct operation therefore depends on communication configuration, network wiring, channel assignment, external power, and suitable contact loading.
Relay contact ratings must be checked against the actual load. Inductive devices such as solenoids may require suitable suppression or interface components to manage switching transients and protect the contacts.
The 9905-973 occupies the discrete output layer of a distributed control system. It connects the controller’s digital commands to external relay-operated circuits, allowing field devices to be switched without assigning the relay module responsibility for the overall control sequence.
Woodward Controller → LINKnet Communication → 9905-973 → Relay Contacts → External Equipment
| System Component | Function |
|---|---|
| Woodward Controller | Executes control logic and generates output commands |
| LINKnet Communication Network | Transfers commands and status information between supported devices |
| 9905-973 Relay Output Module | Provides eight relay output channels |
| External DC Supply | Supplies the required module and field-circuit power according to the installation |
| Solenoid Valve | Operates a fluid or gas control function when commanded |
| Alarm Circuit | Provides an external indication of a configured condition |
| Interlock Circuit | Transfers discrete control signals between system components |
| Terminal Blocks | Organize field wiring and external circuit connections |
| DIN Rail and Grounding Arrangement | Supports module installation and the specified grounding requirements |
| Host Control Logic | Determines when each output should change state |
| Application | Typical Use |
|---|---|
| Turbine Control Systems | Switching auxiliary equipment and discrete control circuits |
| Engine Control Systems | Operating relay-controlled devices under controller commands |
| Generator Installations | Providing discrete outputs for compatible auxiliary functions |
| Industrial Power Plants | Connecting controller logic to field relay circuits |
| Solenoid Valve Control | Switching suitable valve circuits through relay contacts |
| Alarm Annunciation | Activating external alarm or status circuits |
| Equipment Interlocks | Transferring discrete commands within a compatible control scheme |
| Distributed Control Cabinets | Locating relay outputs near the equipment being controlled |
| Industrial Machinery | Operating auxiliary devices through configured relay channels |
| Control-System Maintenance | Replacing a relay output module after verifying network and wiring compatibility |
| Component | Function |
|---|---|
| Woodward 9905-973 LINKnet Module | Provides eight discrete relay output channels |
| Woodward 723 Digital Control | Hosts compatible LINKnet I/O communication and control logic |
| LINKnet Communication Cable | Carries communication between the controller and I/O modules |
| LINKnet Termination Network, 9905-760 | Provides the specified network termination at the final module |
| Grounding Block, 1604-813 | Connects the module’s DIN rail installation to the required grounding arrangement |
| External Power Supply | Supplies the required power to the module and connected circuits |
| Terminal Blocks | Provide organized connections for field wiring |
| Solenoid Valves | Execute commanded valve operations through suitable relay circuits |
| Alarm and Interlock Circuits | Provide external status, annunciation, and switching functions |
| Host Control Application | Defines output assignments and determines relay operating commands |
| Model | Product Type | Typical Application |
|---|---|---|
| Woodward 9905-973 | LINKnet 8-Channel Relay Output Module | Eight-channel discrete relay switching |
| Woodward 9905-971 | LINKnet 16-Channel Discrete Input Module | Receiving external digital status signals |
| Woodward 9905-972 | LINKnet 6-Channel Analog Output Module | Providing configured 4–20 mA output signals |
| Woodward 9905-968 | LINKnet 6-Channel Analog Input Module | Acquiring 4–20 mA signals without 24 V loop power |
| Woodward 9905-969 | LINKnet 6-Channel Analog Input Module | Acquiring 4–20 mA signals with 24 V loop power |
| Woodward 9905-970 | LINKnet 6-Channel RTD Input Module | Measuring temperature using compatible 100 Ω RTDs |
| Woodward 8200-1205 | LINKnet HT 16-Channel Discrete Output Module | Digital output functions in compatible LINKnet HT systems |
The module provides eight relay output channels. Each channel must be assigned and wired according to the control application’s output mapping and the requirements of its connected circuit.
The module uses rotary address switches that must match the address assigned in the controller application. An address mismatch can prevent the controller from communicating with the intended I/O module.
The LINKnet installation uses shielded twisted-pair wiring. The network must follow the specified cable, grounding, shielding, and termination arrangements, including the required termination network at the final module.
No direct substitution should be assumed. The original LINKnet and LINKnet HT systems use different network architectures, so a change requires verification of controller compatibility, communication hardware, application configuration, and wiring requirements.