• Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable
  • Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable
  • Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable
  • Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable
Product Overview The Foxboro P0916NK is a short HDLC communication cable used to connect compatible base-to-base interfaces in Foxboro I/A Series control systems. It has a 9-pin male connector at each e……
Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable
  • Foxboro
  • P0916NK
  • HDLC Base-to-Base Cable
  • USA
  • 0.12 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0916NK I/A Series 9-Pin HDLC Base-to-Base Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0916NK is a short HDLC communication cable used to connect compatible base-to-base interfaces in Foxboro I/A Series control systems. It has a 9-pin male connector at each end and a nominal cable length of 5¼ inches, approximately 0.12 meters. The assembly is associated with 2 Mbps base-to-base communication between compatible Foxboro system components. <Cite refs={[“turn790369search1″,”turn790369search2”]}/>

In a distributed control system, communication between hardware bases allows designated system components to exchange data through their supported interfaces. The P0916NK provides the physical connection for this link. Its short length is suited to closely positioned connection points, where a long cable would add unnecessary slack and complicate cable routing.

During cabinet maintenance, this cable may need attention if a base-to-base communication fault appears after hardware has been moved, replaced, or reconnected. A connector that is not fully seated, damaged contacts, or a broken conductor can interrupt the communication path even when the connected hardware remains operational.

The P0916NK is a passive communication cable, not an active network switch or protocol converter. Its function is to carry the electrical signals between compatible interfaces. The connected equipment determines the communication protocol, timing, and data handling, so the cable should be selected by its complete part number and interface requirements rather than connector appearance alone.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Model P0916NK
Product Family I/A Series
Product Type 9-Pin HDLC Base-to-Base Cable
Communication Protocol HDLC
Communication Rate 2 Mbps
Connector A 9-pin male
Connector B 9-pin male
Cable Length 0.12 meters
Connection Type Base-to-base communication
Operating Function Electrical data transmission
Shipping Weight 3 kg

Product Features

  • HDLC communication link: Supports the designated base-to-base data connection in compatible I/A Series configurations.
  • Dual 9-pin male connectors: Provides matching connector interfaces at both ends.
  • Short cable assembly: Suits closely positioned hardware bases and reduces excess cable slack.
  • Passive signal path: Carries communication signals without independent data processing or signal regeneration.
  • Direct replacement: Allows a matching cable to be replaced without changing the communication architecture.
  • Cabinet-level integration: Fits applications where base-to-base connections must remain organized and accessible for service.

Working Principle

The P0916NK establishes a direct electrical path between two compatible 9-pin base interfaces. When the connected system exchanges HDLC data, the cable carries the electrical signals between the two endpoints.

Foxboro Base Interface A → P0916NK Cable → Foxboro Base Interface B

The cable does not generate or interpret HDLC messages. Communication depends on the connected hardware, the assigned interface functions, and the correct electrical connection. The specified communication rate and interface arrangement must be supported by both endpoints.

Because the assembly is short, connector alignment and mechanical strain deserve particular attention. If the connected bases are positioned too far apart, pulling the cable taut can stress the connector housings or contacts. Conversely, forcing the cable into a tight bend can damage the cable assembly or interfere with secure connector engagement.

When a communication fault occurs, inspect both connectors and the cable before replacing active control hardware. Check that the correct interfaces are connected, the connector fasteners are secure, and the cable has not been crushed or strained during cabinet work.


Role in the Foxboro I/A Series Communication Architecture

The P0916NK occupies the physical connection layer between compatible base interfaces. It supports the communication path, while the connected system hardware handles data exchange and control-system functions.

I/A Series Base A → P0916NK → I/A Series Base B → Connected Control-System Hardware

System Element Function
P0916NK Carries HDLC signals between compatible base interfaces
Base Interface A Provides one endpoint of the communication link
Base Interface B Provides the other endpoint of the communication link
I/A Series Control Hardware Performs the assigned control-system functions
Connector Fasteners Secure the cable at the mating interfaces
Cabinet Wiring Arrangement Maintains separation and routing of communication and power connections

Industrial Applications

Application Practical Use
I/A Series Control Cabinets Connecting compatible base interfaces within an established cabinet layout
Distributed Control Systems Maintaining designated base-to-base communication links
Process Automation Plants Supporting communication connections in installed I/A Series systems
Chemical Processing Facilities Maintaining control-system communication hardware
Oil and Gas Control Systems Supporting compatible hardware interconnections
Power Generation Facilities Replacing a matching cable during planned maintenance
Control Cabinet Refurbishment Restoring a base-to-base connection after hardware replacement
Communication Fault Diagnosis Checking the physical connection when an HDLC link becomes unstable

Installation and Maintenance

  1. Verify the part number: Confirm P0916NK and check that the replacement matches the installed cable reference.
  2. Identify both endpoints: Confirm the designated base interfaces before disconnecting the existing assembly.
  3. Check connector compatibility: Verify the 9-pin male connector arrangement at both ends and the required mating interfaces.
  4. Follow the maintenance procedure: Apply the system’s prescribed isolation or communication-maintenance procedure before disconnecting the cable.
  5. Inspect the cable jacket: Look for cuts, crushing, sharp bends, or other mechanical damage.
  6. Examine connector contacts: Check for bent pins, contamination, corrosion, and damaged connector housings.
  7. Protect the connector interfaces: Avoid forcing the plugs into the mating sockets or tightening fasteners beyond the specified requirements.
  8. Maintain suitable routing: Prevent the cable from being stretched tightly between the bases or trapped beneath adjacent equipment.
  9. Reconnect both ends: Confirm that each connector is fully seated and secured at its designated interface.
  10. Inspect nearby wiring: Check that the cable is not pinched by cabinet doors, mounting hardware, or neighboring components.
  11. Verify communication: Check the relevant system status indications and confirm that the communication fault has cleared.
  12. Record the maintenance work: Document the replacement reference, connection points, inspection findings, and post-maintenance test results.

Compatible System Components

Component Function
Foxboro P0916NK Provides the 9-pin HDLC base-to-base connection
Compatible I/A Series Base Assembly Provides the physical interface for the communication cable
I/A Series Control Hardware Performs the assigned control and data-handling functions
Compatible Base Interface Terminates one end of the cable connection
Compatible Remote Base Interface Terminates the opposite end of the communication link
Connector Retaining Hardware Helps secure the cable at the mating interfaces
Control Cabinet Wiring Routes communication connections between installed components
System Status Interface Allows maintenance personnel to check communication status where supported

Recommended Related Models

Model / Product Family Product Type Typical Application
Foxboro P0916NK 9-Pin HDLC Base-to-Base Cable Replacement of the same cable assembly
Foxboro I/A Series Base Assemblies Control-System Base Hardware Providing the mating interfaces for compatible base connections
Foxboro I/A Series Control Processors Control Processor Executing control logic and coordinating system operation
Foxboro I/A Series Fieldbus Modules (FBMs) Fieldbus Module Handling process input and output signals
Foxboro I/A Series Communication Interfaces Communication Interface Supporting data exchange between compatible system components
Foxboro I/A Series System Baseplates Modular Baseplate Housing and interconnecting supported control-system hardware

Key Advantages

  • Provides a dedicated HDLC communication path between compatible base interfaces.
  • Uses matching 9-pin male connectors at both ends.
  • Supports short-distance connections within established I/A Series installations.
  • Allows a matching cable to be replaced without redesigning the communication architecture.

Technical FAQs

What is the function of the P0916NK in an I/A Series installation?

It provides a physical HDLC communication connection between compatible system bases. The connected hardware handles the actual communication protocol and data processing.

Are both connectors on the P0916NK male?

Yes. The assembly is specified with a 9-pin male connector at each end. The mating interfaces must therefore have the corresponding compatible connector arrangement.

Why might a communication fault occur after the cable has been reconnected?

Possible causes include a connector that is not fully seated, bent pins, damaged conductors, or connection to the wrong interface. Check the cable and both endpoints before replacing active system hardware.

Can a longer 9-pin cable be substituted for the P0916NK?

Not automatically. The replacement must match the required pinout, electrical characteristics, and interface requirements. Cable length and connector compatibility alone do not establish suitability for the HDLC connection.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501