• Bently Nevada 60R/REC01-00-0 Recorder Output Module
  • Bently Nevada 60R/REC01-00-0 Recorder Output Module
  • Bently Nevada 60R/REC01-00-0 Recorder Output Module
  • Bently Nevada 60R/REC01-00-0 Recorder Output Module
Product Overview The Bently Nevada 60R/REC01-00-0 Recorder Output Module is an output module used within the Bently Nevada 60R machinery monitoring architecture. Its primary role is associated with send……
Bently Nevada 60R/REC01-00-0 Recorder Output Module
  • Bently Nevada
  • 60R/REC01-00-0
  • Recorder Output Module
  • USA
  • 132.1 × 20.3 × 245.6 mm
  • 1.2 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 11

Our advantage

Bently Nevada 60R/REC01-00-0 Recorder Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Bently Nevada 60R/REC01-00-0 Recorder Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Bently Nevada 60R/REC01-00-0 Recorder Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Bently Nevada 60R/REC01-00-0 Recorder Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Bently Nevada 60R/REC01-00-0 Recorder Output Module is an output module used within the Bently Nevada 60R machinery monitoring architecture. Its primary role is associated with sending selected monitoring information to external recording or data-acquisition equipment.

In a machinery monitoring installation, measurement modules acquire parameters such as vibration and temperature, while other system components process and evaluate those signals. A recorder output function allows selected information to be made available to external recording equipment for trending, historical analysis, documentation, or integration with another monitoring layer.

The REC01-00-0 therefore sits on the output side of the monitoring architecture, rather than serving as a direct sensor interface. It can be useful where machine-condition data needs to be preserved or presented to equipment outside the primary monitoring rack.


Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model 60R/REC01-00-0
Product Type Recorder Output Module
Main Function Recorder / Monitoring Data Output
Application Bently Nevada 60R Monitoring System
Dimensions 132.1 × 20.3 × 245.6 mm
Weight 1.2 kg

Main Features

The REC01-00-0 is associated with the output and recording side of the 60R monitoring system.

  • Bently Nevada 60R Recorder Output Module
  • Intended for monitoring-data output
  • Interfaces the monitoring architecture with external recording equipment
  • Suitable for machinery condition-monitoring applications
  • Can support long-term machine-data recording
  • Useful for historical trend analysis
  • Works alongside measurement and protection modules
  • Suitable for modular 3U monitoring systems
  • Useful for monitoring-system integration and maintenance
  • Dimensions of 132.1 × 20.3 × 245.6 mm
  • Weight of 1.2 kg

The exact output configuration and external recording arrangement depend on the overall 60R system design.


Working Principle

The 60R/REC01-00-0 operates on the output side of the monitoring signal chain.

A simplified architecture is:

Machine Sensors → Input Modules → Monitoring / Processing → REC01-00-0 → Recorder / External Equipment

Measurement modules first acquire information from sensors installed on the machine. The monitoring system then processes or evaluates the relevant data.

The REC01-00-0 provides an interface through which selected monitoring information can be made available to recording equipment. This allows machine-condition information to be retained for later review rather than being used only for real-time monitoring.

Recorded information can be useful when investigating intermittent problems, comparing machine behavior over time, or correlating machinery events with process conditions.

The recorder output function is therefore complementary to the system’s protection and monitoring functions.


Role in Machinery Data Recording

A machinery monitoring system can have several information paths operating simultaneously:

Sensor Input → Monitoring → Protection

and

Sensor Input → Monitoring → Recording / Historical Analysis

The REC01-00-0 belongs to the second path.

This is useful because some machinery problems are not continuously present. An engineer may need to review historical information to determine when a vibration or temperature trend began changing.

For example, data recorded during normal operation can later be compared with data collected during:

  • Startup
  • Shutdown
  • Load changes
  • Process disturbances
  • Mechanical faults
  • Maintenance events
  • Abnormal vibration conditions

This makes recorder output particularly useful for condition-based maintenance and post-event analysis.


Industrial Applications

The 60R/REC01-00-0 is suited to machinery monitoring installations where machine-condition information needs to be transferred to recording equipment.

Application Typical Use
Steam Turbines Recording operating-condition data
Gas Turbines Historical machinery analysis
Generators Machine-condition data recording
Compressors Trend and event analysis
Pumps Long-term condition monitoring
Motors Operating-data recording
Gearboxes Mechanical-condition trending
Process Machinery Data logging
Rotating Equipment Historical performance analysis
Industrial Plants Integration with recording systems

It is especially useful in facilities where historical machinery data is required for maintenance planning or failure investigation.


Integration with the 60R Monitoring System

The recorder output module works as part of a larger monitoring architecture.

A typical arrangement can be represented as:

Machine → Sensors → Input Modules → Monitoring / Protection → REC01-00-0 → External Recorder

Other modules can perform specialized functions before the data reaches the output stage.

For example:

  • 60R/INP01 — dynamic signal acquisition
  • 60R/INP07 — RTD/thermocouple temperature acquisition
  • 60R/PPM01-00-0 — protection processing
  • 60R/CMM01 — condition monitoring
  • 60R/REC01-00-0 — recorder output

This modular arrangement allows measurement, protection, analysis, and recording functions to be separated within the same monitoring architecture.


Installation and Maintenance

Before replacing the REC01-00-0, the external recording arrangement and monitoring-system configuration should be documented.

Recommended checks include:

  • Confirm the complete 60R/REC01-00-0 part number.
  • Verify the compatible 60R chassis.
  • Identify the connected recording equipment.
  • Record existing output configuration.
  • Inspect module connectors.
  • Check rack contacts.
  • Verify associated input and processing modules.
  • Check external recording-system wiring.
  • Follow the plant’s machinery-monitoring maintenance procedure.

After installation:

  • Verify the module is correctly seated.
  • Check connections to the external recording system.
  • Confirm that the monitoring rack recognizes the module.
  • Verify output data.
  • Check recorded values against expected machine conditions.
  • Confirm that historical data is being captured correctly.
  • Review system diagnostics.

If the recorder receives no data after module replacement, the troubleshooting path should include the source monitoring module, system configuration, output connections, and external recorder rather than focusing exclusively on the REC01-00-0.


Related Components

Component Function
60R/CHA02 3U monitoring chassis
60R/PIM01-00-0 Monitoring-system power input
60R/INP01 Dynamic signal acquisition
60R/INP01-00-0 Dynamic signal acquisition
60R/INP07 RTD/TC temperature acquisition
60R/CMM01 Condition monitoring
60R/PPM01-00-0 Protection processing
60R/REC01-00-0 Recorder output
External Recorder Historical data recording
Machinery Sensors Machine-condition measurement

Recommended Related Models

Model Product Type Main Function Typical Application
Bently Nevada 60R/REC01-00-0 Recorder Output Module Monitoring data output Historical recording
Bently Nevada 60R/PPM01-00-0 Protection Processing Module Protection processing Machinery protection
Bently Nevada 60R/CMM01 Condition Monitoring Module Condition monitoring Machine analysis
Bently Nevada 60R/INP01 Dynamic Input Module Dynamic signal acquisition Vibration monitoring
Bently Nevada 60R/INP07 RTD/TC Temperature Module Temperature acquisition Temperature monitoring
Bently Nevada 60R/PIM01-00-0 3U Power Input Module Rack power input Monitoring-system power

These modules serve different stages of the monitoring architecture and are normally selected according to the required measurement, protection, recording, and power functions.


Key Advantages

  • Dedicated recorder output function
  • Suitable for Bently Nevada 60R monitoring architecture
  • Supports transfer of monitoring information to recording equipment
  • Useful for historical machine-condition analysis
  • Suitable for long-term trend recording
  • Can complement vibration and temperature monitoring
  • Works with protection and condition-monitoring modules
  • Suitable for industrial rotating equipment
  • Modular 3U construction
  • Dimensions of 132.1 × 20.3 × 245.6 mm
  • Weight of 1.2 kg

Technical FAQs

What is the purpose of the Bently Nevada 60R/REC01-00-0?

The 60R/REC01-00-0 is a Recorder Output Module used to make selected monitoring information available to external recording equipment. It is intended for the output and recording side of the 60R monitoring architecture.

How is the REC01-00-0 different from a dynamic input module?

A dynamic input module acquires signals originating from machinery sensors, while the REC01-00-0 operates further along the signal path and is associated with outputting monitoring information for recording. The two modules therefore serve different stages of the monitoring system.

Why is historical recording useful in machinery monitoring?

Historical data allows engineers to compare machine behavior before, during, and after abnormal events. This can help identify gradual deterioration, intermittent faults, load-related changes, and trends that may not be obvious from a single real-time measurement.

What should be checked if the external recorder receives no signal?

Check the monitoring source, module configuration, REC01-00-0 installation, output connections, external recorder, and associated wiring. It is important to determine whether the problem originates from the source data, output module, or recording equipment before replacing hardware.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501