Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Bently Nevada 60R/REC01-00-0 Recorder Output Module is an output module used within the Bently Nevada 60R machinery monitoring architecture. Its primary role is associated with sending selected monitoring information to external recording or data-acquisition equipment.
In a machinery monitoring installation, measurement modules acquire parameters such as vibration and temperature, while other system components process and evaluate those signals. A recorder output function allows selected information to be made available to external recording equipment for trending, historical analysis, documentation, or integration with another monitoring layer.
The REC01-00-0 therefore sits on the output side of the monitoring architecture, rather than serving as a direct sensor interface. It can be useful where machine-condition data needs to be preserved or presented to equipment outside the primary monitoring rack.
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Model | 60R/REC01-00-0 |
| Product Type | Recorder Output Module |
| Main Function | Recorder / Monitoring Data Output |
| Application | Bently Nevada 60R Monitoring System |
| Dimensions | 132.1 × 20.3 × 245.6 mm |
| Weight | 1.2 kg |
The REC01-00-0 is associated with the output and recording side of the 60R monitoring system.
The exact output configuration and external recording arrangement depend on the overall 60R system design.
The 60R/REC01-00-0 operates on the output side of the monitoring signal chain.
A simplified architecture is:
Machine Sensors → Input Modules → Monitoring / Processing → REC01-00-0 → Recorder / External Equipment
Measurement modules first acquire information from sensors installed on the machine. The monitoring system then processes or evaluates the relevant data.
The REC01-00-0 provides an interface through which selected monitoring information can be made available to recording equipment. This allows machine-condition information to be retained for later review rather than being used only for real-time monitoring.
Recorded information can be useful when investigating intermittent problems, comparing machine behavior over time, or correlating machinery events with process conditions.
The recorder output function is therefore complementary to the system’s protection and monitoring functions.
A machinery monitoring system can have several information paths operating simultaneously:
Sensor Input → Monitoring → Protection
and
Sensor Input → Monitoring → Recording / Historical Analysis
The REC01-00-0 belongs to the second path.
This is useful because some machinery problems are not continuously present. An engineer may need to review historical information to determine when a vibration or temperature trend began changing.
For example, data recorded during normal operation can later be compared with data collected during:
This makes recorder output particularly useful for condition-based maintenance and post-event analysis.
The 60R/REC01-00-0 is suited to machinery monitoring installations where machine-condition information needs to be transferred to recording equipment.
| Application | Typical Use |
|---|---|
| Steam Turbines | Recording operating-condition data |
| Gas Turbines | Historical machinery analysis |
| Generators | Machine-condition data recording |
| Compressors | Trend and event analysis |
| Pumps | Long-term condition monitoring |
| Motors | Operating-data recording |
| Gearboxes | Mechanical-condition trending |
| Process Machinery | Data logging |
| Rotating Equipment | Historical performance analysis |
| Industrial Plants | Integration with recording systems |
It is especially useful in facilities where historical machinery data is required for maintenance planning or failure investigation.
The recorder output module works as part of a larger monitoring architecture.
A typical arrangement can be represented as:
Machine → Sensors → Input Modules → Monitoring / Protection → REC01-00-0 → External Recorder
Other modules can perform specialized functions before the data reaches the output stage.
For example:
This modular arrangement allows measurement, protection, analysis, and recording functions to be separated within the same monitoring architecture.
Before replacing the REC01-00-0, the external recording arrangement and monitoring-system configuration should be documented.
Recommended checks include:
After installation:
If the recorder receives no data after module replacement, the troubleshooting path should include the source monitoring module, system configuration, output connections, and external recorder rather than focusing exclusively on the REC01-00-0.
| Component | Function |
|---|---|
| 60R/CHA02 | 3U monitoring chassis |
| 60R/PIM01-00-0 | Monitoring-system power input |
| 60R/INP01 | Dynamic signal acquisition |
| 60R/INP01-00-0 | Dynamic signal acquisition |
| 60R/INP07 | RTD/TC temperature acquisition |
| 60R/CMM01 | Condition monitoring |
| 60R/PPM01-00-0 | Protection processing |
| 60R/REC01-00-0 | Recorder output |
| External Recorder | Historical data recording |
| Machinery Sensors | Machine-condition measurement |
| Model | Product Type | Main Function | Typical Application |
|---|---|---|---|
| Bently Nevada 60R/REC01-00-0 | Recorder Output Module | Monitoring data output | Historical recording |
| Bently Nevada 60R/PPM01-00-0 | Protection Processing Module | Protection processing | Machinery protection |
| Bently Nevada 60R/CMM01 | Condition Monitoring Module | Condition monitoring | Machine analysis |
| Bently Nevada 60R/INP01 | Dynamic Input Module | Dynamic signal acquisition | Vibration monitoring |
| Bently Nevada 60R/INP07 | RTD/TC Temperature Module | Temperature acquisition | Temperature monitoring |
| Bently Nevada 60R/PIM01-00-0 | 3U Power Input Module | Rack power input | Monitoring-system power |
These modules serve different stages of the monitoring architecture and are normally selected according to the required measurement, protection, recording, and power functions.
The 60R/REC01-00-0 is a Recorder Output Module used to make selected monitoring information available to external recording equipment. It is intended for the output and recording side of the 60R monitoring architecture.
A dynamic input module acquires signals originating from machinery sensors, while the REC01-00-0 operates further along the signal path and is associated with outputting monitoring information for recording. The two modules therefore serve different stages of the monitoring system.
Historical data allows engineers to compare machine behavior before, during, and after abnormal events. This can help identify gradual deterioration, intermittent faults, load-related changes, and trends that may not be obvious from a single real-time measurement.
Check the monitoring source, module configuration, REC01-00-0 installation, output connections, external recorder, and associated wiring. It is important to determine whether the problem originates from the source data, output module, or recording equipment before replacing hardware.