The Schneider Electric TM2DRA16RT is a 16-channel relay output module for the Modicon M238 logic controller. It provides relay-based switching for connecting PLC control outputs to external electrical loads, including contactors, indicator devices, solenoid valves, and other industrial actuators.
Unlike transistor output modules, the TM2DRA16RT uses electromechanical relay contacts. Each output provides one normally open (NO) contact, allowing the controller to switch compatible AC or DC loads. The module has two common terminal groups, with eight output channels assigned to each group.
Each relay channel supports a maximum switching current of 2 A, while the maximum current per common group is 8 A. This arrangement allows the module to control different loads while maintaining separate common connections.
The removable screw terminal block simplifies field wiring and makes it easier to disconnect the output wiring during maintenance or module replacement. Individual output states can be monitored through the module’s local indication.
The TM2DRA16RT is suitable for Modicon M238 installations requiring relay-based output switching, particularly where the connected equipment operates at different voltage levels or requires electrically isolated switching contacts.
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Model | TM2DRA16RT |
| Product Series | Modicon M238 |
| Product Type | Discrete Output Module |
| Output Channels | 16 |
| Output Type | Relay |
| Output Contact | 1 NO per Channel |
| Number of Common Groups | 2 |
| Channels per Common Group | 8 |
| Maximum Current per Channel | 2 A |
| Maximum Current per Common Group | 8 A |
| Rated Output Voltage | 24 V DC / 230–240 V AC |
| Maximum Output Voltage | 30 V DC / 264 V AC |
| Minimum Switching Load | 0.1 mA at 0.1 V DC |
| Contact Resistance | ≤ 45 mΩ |
| Response Time | ≤ 10 ms OFF to ON; ≤ 5 ms ON to OFF |
| Mechanical Durability | 20 million cycles |
| Electrical Connection | 1 Removable Screw Terminal Block |
| Mounting | 35 mm Symmetrical DIN Rail |
| Current Consumption | 30 mA at 5 V DC; 40 mA at 24 V DC |
| Channel Isolation | 1500 V for 1 minute |
| Isolation Between Outputs and Internal Logic | 2300 V for 1 minute |
| Local Signalling | 1 Display Block |
| Dimensions | 90 × 27.3 × 84.6 mm |
| Weight | 0.145 kg |
The TM2DRA16RT converts digital control commands from the Modicon M238 controller into electrical switching actions through its 16 electromechanical relay channels.
Its operation involves several stages.
1. Controller Output Command
The Modicon M238 executes its control program and determines which relay outputs need to be activated according to the machine or process conditions.
2. Internal Relay Activation
When an output command is issued, the corresponding internal relay coil is energized through the module’s control circuitry.
3. Contact Switching
The relay’s normally open contact changes to its closed state, allowing current to flow through the connected external circuit.
4. Load Operation
The switched circuit supplies the connected load, such as a contactor coil, solenoid valve, or indicator device. When the controller removes the output command, the relay returns to its normally open state.
5. Independent Output Groups
The 16 outputs are arranged into two common groups. Each group contains eight channels, and the two common groups are not internally connected to each other.
6. Output Monitoring
The module provides local indication for monitoring output conditions. Maintenance personnel can use these indicators alongside controller diagnostics to identify switching or wiring problems.
A simplified control arrangement is:
Modicon M238 Controller → TM2DRA16RT → Relay Contacts → External Electrical Loads
Because the module uses electromechanical relays, its switching characteristics and electrical durability must be considered when selecting loads and determining switching frequency.
Within a Modicon M238 automation system, the TM2DRA16RT serves as the relay-based output interface between the PLC and external electrical equipment.
The controller processes input signals and executes application logic, while the TM2DRA16RT performs the physical switching required to operate connected loads.
Its two common groups allow different output circuits to be wired separately, which is useful when a machine contains several groups of actuators or equipment operating on different supply circuits.
| System Component | Function |
|---|---|
| Modicon M238 Controller | Executes machine control logic |
| TM2DRA16RT | Provides 16 relay output channels |
| TM2 Digital Input Modules | Acquire digital signals from field devices |
| TM2 Analog Input Modules | Acquire analog process measurements |
| TM2 Analog Output Modules | Generate analog control signals |
| Contactors | Switch motors and other electrical loads |
| Solenoid Valves | Control pneumatic and hydraulic actuators |
| Indicator Lamps | Display machine operating conditions |
| Protective Fuses | Protect external output circuits |
The TM2DRA16RT is used in machine automation systems where PLC-controlled relay switching is required.
| Industrial Application | Typical Use |
|---|---|
| Packaging Machinery | Switching conveyor motors and machine actuators through contactors |
| Material Handling | Controlling conveyor equipment and auxiliary devices |
| Assembly Machines | Operating pneumatic valves and machine mechanisms |
| Food Processing | Switching pumps, valves, and auxiliary equipment |
| Water Treatment | Controlling pumps and process valves |
| Industrial Conveyors | Operating contactors and warning indicators |
| Machine Tools | Switching auxiliary machine functions |
| Automated Production Lines | Controlling multiple independent electrical loads |
| HVAC Systems | Switching fans, dampers, and auxiliary equipment |
| Industrial Utilities | Controlling electrical equipment through relay interfaces |
| Component | Function |
|---|---|
| Schneider TM2DRA16RT | 16-Channel Relay Output Module |
| Schneider Modicon M238 | Logic Controller |
| Schneider TM2DOCKN | M218 Expansion Interface Module |
| Schneider TM2DMM16DRTN | Digital Mixed I/O Module |
| Schneider TM2DDO8TT | Discrete Output Module |
| Schneider TM2DDO32UK | Discrete Output Module |
| Schneider TM2ARI8LT | Analog Input Module |
| Schneider TM2AMO2HTN | Analog Output Module |
| Schneider TM2AVO2HT | Analog Output Module |
| Model | Product Type | Application |
|---|---|---|
| Schneider TM2DDO8TT | Modicon M238 Discrete Output Module | Transistor output switching |
| Schneider TM2DDO32UK | Modicon M238 Discrete Output Module | 32-channel digital output control |
| Schneider TM2DMM8DRT | Modicon M238 Discrete I/O Module | Combined digital input and relay output |
| Schneider TM2DMM24DRF | Modicon M238 Discrete I/O Module | Mixed digital I/O expansion |
| Schneider TM2AMO2HTN | Modicon TM2 Analog Output Module | Analog control signal generation |
| Schneider TM2ARI8LT | Modicon M238 Analog Input Module | Analog process signal acquisition |
The module has 16 relay output contacts divided into two common groups. Each group contains eight channels. The two common groups are not internally connected, allowing separate external circuit connections.
Yes. Its relay contacts support compatible AC and DC applications. The rated voltage is 24 V DC or 230–240 V AC, with a maximum current of 2 A per channel. The load type and switching frequency must also remain within the specified electrical durability limits.
It can switch suitable inductive loads within its electrical ratings, but external protective circuits are required for inductive AC loads to reduce contact damage. Capacitive loads are not supported.
The TM2DRA16RT uses electromechanical relay contacts, allowing it to switch compatible AC and DC circuits. Transistor output modules use semiconductor switching and are generally more suitable for applications requiring higher switching frequencies. The choice depends on load type, voltage, switching speed, and service-life requirements.