Installation Guide for the Allen-Bradley 1336-SN-SP6A Inverter Snubber PCB

2026-11-25 

The Allen-Bradley 1336-SN-SP6A is an inverter snubber printed circuit board (PCB) used in applicable 1336STEF variable frequency drive assemblies. Its function is to help control transient voltage stresses associated with inverter switching. Correct installation requires more than matching the part number: technicians must verify the drive’s complete catalog number, voltage class, horsepower rating, frame, and existing board arrangement before replacing the assembly.

The 1336-SN-SP6A is identified in the 1336 spare-parts documentation as an inverter snubber PCB for specified 1336STEF drive configurations. The listed kit quantity is three boards per applicable drive assembly. Because the 1336 product family includes several electrically and mechanically different snubber assemblies, this part should not be selected solely because the drive carries a 1336 model prefix.

Contents of This 1336-SN-SP6A Installation Guide

  1. Product identification and compatibility
  2. Inverter snubber PCB function
  3. Pre-installation checks and safety
  4. Removal and replacement procedure
  5. Inspection and commissioning
  6. Drive integration considerations
  7. Technical FAQs

1336-SN-SP6A Product Identification and Drive Compatibility

Before installation, confirm that the replacement PCB is exactly 1336-SN-SP6A. Similar-looking parts in the 1336 family may serve as converter snubber boards, inverter snubber boards, or combined assemblies. Their electrical characteristics and mounting arrangements are not necessarily interchangeable.

The spare-parts listing associates 1336-SN-SP6A with the 1336STEF family and identifies a 460 V configuration covering specified 60–100 HP applications. Other product information for the catalog number also identifies 230 V and 575 V drive ratings. These ratings refer to different drive configurations, not permission to install the same board in any drive within those voltage classes.

  • Manufacturer: Allen-Bradley / Rockwell Automation
  • Catalog number: 1336-SN-SP6A
  • Component type: Inverter snubber PCB
  • Associated drive family: 1336STEF
  • Spare-parts kit quantity: Three boards for applicable assemblies
  • Product lifecycle: Discontinued

Check the drive nameplate and the corresponding parts list before ordering or installing the kit. If the drive has been modified, repaired with a previous-generation board, or rebuilt using a different power-stage assembly, verify the actual installed configuration rather than relying on the original machine documentation alone.

How the 1336 Inverter Snubber PCB Supports Drive Operation

An inverter power stage switches DC bus energy through semiconductor devices to produce a controlled AC output for the motor. Switching transitions and circuit parasitics can create transient voltage stress. A snubber network helps manage these transients and reduces electrical stress on the associated switching components.

The 1336-SN-SP6A is part of this inverter-side protection arrangement. It should be treated as a component of the drive’s engineered power-stage design, not as a general-purpose surge suppressor. Its circuit layout, electrical connections, and installation position must match the specified drive assembly.

A damaged snubber PCB may be associated with visible component damage, abnormal switching behavior, repeated drive faults, or secondary damage in the power section. However, these symptoms are not proof that the snubber board itself has failed. The inverter power devices, gate-drive circuits, bus connections, motor cable, and load conditions should also be evaluated.

Pre-Installation Checks and Electrical Safety for 1336-SN-SP6A

Work inside a 1336 drive involves hazardous line voltage and stored DC bus energy. Only qualified personnel familiar with the specific drive model should perform this replacement. Follow the applicable Rockwell Automation installation and maintenance instructions and the site’s electrical safety procedures.

1. Isolate the drive

  • Stop the machine using the approved shutdown sequence.
  • Disconnect and lock out all incoming power sources.
  • Isolate any auxiliary or external supply circuits that could energize the equipment.
  • Apply the site’s lockout/tagout procedure and verify that the equipment cannot restart.

2. Verify that the DC bus is safe

DC bus capacitors can retain hazardous energy after the incoming supply has been disconnected. Wait for the discharge period specified in the exact drive manual. Then use an appropriately rated meter and the designated test points to verify the voltage condition. Do not assume that the bus is discharged because the display is blank or the power indicator is off.

3. Record the existing assembly

  • Record the complete drive catalog number and serial number.
  • Confirm the voltage class, horsepower rating, and frame.
  • Photograph the installed snubber boards and their connections.
  • Identify board labels, connector positions, fasteners, and cable routing.
  • Compare the existing assembly with the correct parts diagram.

4. Inspect the replacement kit

Check the catalog number, board condition, connector integrity, PCB surfaces, and supplied fastening hardware. Reject any board with cracked substrates, damaged traces, loose components, corrosion, or signs of moisture contamination. Use appropriate ESD protection when handling exposed circuit boards.

Replacing the Allen-Bradley 1336-SN-SP6A Inverter Snubber PCB

The following sequence provides a general maintenance framework. The exact mounting locations, electrical connections, fastener requirements, and board orientation must be taken from the parts diagram and service instructions for the specific 1336 drive configuration.

Step 1: Confirm the replacement scope

Determine whether the maintenance task requires replacement of the complete three-board set. The spare-parts listing identifies three 1336-SN-SP6A boards for applicable assemblies. Do not assume that replacing only one board is acceptable when the approved service procedure specifies a complete set.

Step 2: Inspect the surrounding inverter section

Before removing the original boards, examine the surrounding power-stage area. Look for discoloration, cracked insulation, carbon tracking, damaged connectors, loose hardware, and evidence of overheating. If a snubber board has failed catastrophically, check adjacent components for secondary damage.

Step 3: Remove the original boards

  1. Verify the isolation and DC bus safety checks again before touching the assembly.
  2. Use the recorded photographs and the correct parts diagram to identify each board and connection.
  3. Label connectors where necessary to prevent position changes.
  4. Remove the specified fasteners using suitable tools.
  5. Release connectors carefully without pulling on wires or stressing PCB terminals.
  6. Remove each board while avoiding contact with adjacent components.

Do not force a board out of a mounting position. Resistance may indicate an overlooked fastener, retaining feature, or connection. Forcing the assembly can damage the PCB, connector, or supporting structure.

Step 4: Install the replacement boards

  1. Compare each replacement board with the original part and the applicable assembly drawing.
  2. Confirm board orientation and mounting position.
  3. Check that connectors and terminals are clean and undamaged.
  4. Seat each board without twisting or bending the PCB.
  5. Install the specified fastening hardware.
  6. Tighten fasteners according to the drive service documentation; do not invent or substitute torque values.
  7. Reconnect the wiring and verify that each connection is in its documented position.

Step 5: Complete a mechanical and electrical inspection

Check that all boards are seated correctly, no wiring is trapped, and no tools or loose hardware remain inside the enclosure. Confirm that the installed arrangement matches the correct drive-specific drawing. Do not energize the drive if there is uncertainty about a connector position, missing fastener, damaged insulator, or incorrect board orientation.

1336-SN-SP6A Post-Installation Inspection and Commissioning

Commissioning should begin only after the enclosure has been inspected and all protective covers and barriers have been restored according to the manufacturer’s instructions.

Pre-energization checklist

  • Drive catalog number and snubber PCB compatibility verified.
  • Correct number of replacement boards installed where required.
  • All connectors and mounting hardware checked.
  • No loose tools, fasteners, or foreign objects inside the enclosure.
  • Protective barriers and covers restored.
  • Motor and machine load checked for readiness.

Controlled power-up

Restore power in accordance with the machine’s approved startup procedure. Observe the drive for abnormal indications, unusual sound, unexpected heating, or immediate fault conditions. Do not repeatedly reset a fault without identifying its cause.

If the drive starts normally, perform an initial operation under controlled conditions. Where the process permits, begin with a low-risk operating condition and verify that the motor responds correctly to the commanded speed and load. Compare operating current and other available drive diagnostics with the expected values for the application.

Record the maintenance results

Document the replacement date, drive catalog number, installed part number, kit quantity, observed damage, inspection results, and commissioning status. These records help maintenance teams distinguish a recurring power-stage problem from an isolated component failure.

System Integration Considerations for the 1336-SN-SP6A

The snubber PCB operates within the drive’s inverter power section. Its performance is therefore influenced by the condition of the surrounding electrical system. Before returning a repaired drive to continuous operation, review the following areas:

  • Motor insulation: Check for insulation deterioration or winding faults that could increase electrical stress.
  • Motor cable: Inspect cable insulation, grounding, termination quality, and routing.
  • Grounding: Confirm that protective grounding connections are secure and comply with the drive installation requirements.
  • Cooling: Check fans, air passages, filters, and enclosure ventilation.
  • Power devices: Investigate signs of damage to inverter switching devices and associated gate-drive circuits.
  • Load conditions: Review acceleration, deceleration, duty cycle, and abnormal mechanical loading.

The 1336-SN-SP6A is a discontinued component. When planning long-term maintenance, confirm the availability and authenticity of replacement stock and retain the drive-specific documentation needed to support future service. Rockwell Automation lists no direct replacement category for this catalog number, so a substitute should never be selected based only on physical similarity.

Technical FAQs About Allen-Bradley 1336-SN-SP6A Installation

What is the Allen-Bradley 1336-SN-SP6A?

It is an inverter snubber printed circuit board used in specified Allen-Bradley 1336STEF drive assemblies.

How many 1336-SN-SP6A boards are required?

The spare-parts listing identifies a quantity of three boards for applicable drive assemblies. Confirm the quantity against the exact drive parts list before installation.

Which drive family uses the 1336-SN-SP6A?

The part is associated with the 1336STEF family. The complete drive catalog number and configuration must be checked before use.

Can the 1336-SN-SP6A be installed in every 1336 drive?

No. The 1336 family includes different voltage classes, frames, and power-stage designs. The correct snubber PCB must match the specific drive configuration.

Is the 1336-SN-SP6A a converter snubber board?

No. It is identified as an inverter snubber PCB. Converter-side snubber boards have different functions and may use different catalog numbers.

Does the drive need to be fully isolated before replacement?

Yes. Incoming and auxiliary power sources must be isolated, and the DC bus must be verified safe using the procedure in the applicable drive manual.

Can only one board be replaced?

The correct replacement scope depends on the drive-specific service procedure. Since the parts listing identifies a three-board set, verify whether the approved repair requires all three boards to be replaced together.

What should be checked before installing a replacement PCB?

Verify the catalog number, voltage class, horsepower rating, frame, board condition, connector arrangement, and mounting configuration.

Is the 1336-SN-SP6A still manufactured?

Rockwell Automation lists the product as discontinued, with a discontinuation date of March 31, 2022. Confirm current replacement availability before planning a repair.

What should be done if the drive faults after installation?

Keep the drive out of service until the fault is diagnosed. Review the fault code, installation records, board connections, inverter power devices, motor circuit, and cooling system before attempting another startup.

Conclusion: Reliable Replacement of the 1336-SN-SP6A Inverter Snubber PCB

Replacing the Allen-Bradley 1336-SN-SP6A requires accurate drive identification, strict electrical isolation, careful PCB handling, and a controlled commissioning process. The part is intended for specified 1336STEF inverter assemblies and should not be treated as a universal replacement for other 1336 snubber boards.

For maintenance teams supporting legacy 1336 equipment, the most important step is to verify the complete drive configuration before ordering or installing the replacement. Correct compatibility checks and a documented post-repair inspection help reduce installation errors and protect the inverter power stage.

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501