Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Siemens 6AG2333-0SB00-4AY0 is a SIPLUS PS PSU2600 24V/5A TX RAIL power supply designed to provide a regulated 24 V DC supply for industrial equipment. It is intended for applications requiring a stable DC power source and enhanced environmental resistance, including installations exposed to demanding operating conditions.
Unlike a conventional AC-input power supply, this model uses a 110 V DC nominal input and converts it into a regulated 24 V DC output. This makes it relevant to specialized industrial and railway-related power architectures where a DC supply is available upstream.
The TX RAIL version belongs to the SIPLUS range and features conformal coating for improved resistance to environmental substances. Its DIN rail mounting arrangement supports installation in suitable electrical cabinets and control enclosures.
| Parameter | Description |
|---|---|
| Brand | Siemens |
| Model | 6AG2333-0SB00-4AY0 |
| Product Family | SIPLUS Power Supplies |
| Product Type | PS PSU2600 24V/5A TX RAIL Power Supply |
| Input Voltage | 110 V DC nominal |
| Input Voltage Range | 77–154 V DC |
| Output Voltage | 24 V DC |
| Rated Output Current | 5 A |
| Rated Output Power | 120 W |
| Adjustable Output Voltage | 24–28.8 V DC |
| Mounting | DIN rail |
| Connection Type | Screw terminals |
| Environmental Protection Feature | Conformal coating |
| Operating Temperature | -40 to +70 °C under specified conditions |
| Dimensions | 135 × 135 × 60 mm |
| Weight | 0.5 kg |
The output current is subject to temperature-dependent limitations. The specified output is 5 A up to +60 °C and 4 A up to +70 °C. The extended temperature conditions, including short-duration operation at higher temperatures, must be assessed according to the manufacturer’s installation and operating requirements.
The PSU2600 converts an incoming DC supply into a regulated 24 V DC output. Its input stage accepts a nominal 110 V DC supply, with a specified input range of 77–154 V DC. The output stage provides a controlled and electrically isolated DC voltage for connected equipment.
The rated output current is 5 A, corresponding to a nominal output power of 120 W at 24 V. The output voltage can be adjusted through the integrated potentiometer within the specified 24–28.8 V range.
This adjustment can help accommodate equipment with particular DC voltage requirements. However, the selected output voltage must remain within the limits of every connected device.
Important functional characteristics include:
The SIPLUS TX RAIL design is intended for demanding applications associated with railway environments. It can provide a 24 V DC supply for compatible control and auxiliary equipment when connected to an appropriate upstream DC source.
The module should be installed in accordance with the applicable railway electrical and environmental requirements. Its use does not eliminate the need for suitable upstream protection or system-level power design.
Industrial cabinets often contain PLC-related equipment, communication devices, interface components, and monitoring circuits that require a stable DC supply. The PSU2600 can provide a 24 V DC source where the available input is within its specified DC range.
Remote control equipment and auxiliary automation assemblies may require a local DC supply. The PSU2600 can be considered for these installations when the total load, input source, and environmental conditions are compatible with its ratings.
Specialized transportation and infrastructure systems may use DC power distribution architectures. The PSU2600 provides a conversion option for applications requiring regulated 24 V DC from a higher-voltage DC supply.
Monitoring circuits, status interfaces, and other compatible electronic loads may use the unit as their DC power source. The available output capacity must be calculated before connecting multiple devices.
Correct installation is essential for safe operation and reliable power delivery. The input voltage of this model is particularly important: it is designed for a nominal 110 V DC supply, not a conventional 110 V AC input.
Before installation, confirm that the upstream source provides DC voltage within the specified 77–154 V range. Check polarity, voltage stability, available current, and upstream protective devices.
Never connect an AC source simply because its nominal voltage appears similar to the rated DC input.
Install the unit on a suitable DIN rail in accordance with the manufacturer’s mounting instructions. Ensure that the mounting surface is secure and that sufficient space is available for ventilation and maintenance access.
Use the designated screw terminals and follow the terminal identification in the product documentation. Check conductor size, tightening requirements, polarity, and protective grounding arrangements before energizing the unit.
The nominal output capacity is 24 V DC at 5 A, or 120 W. Confirm that the combined load remains within the permitted output current, taking account of ambient temperature and any applicable derating.
For example, loads operating close to the maximum rating may require additional capacity planning or a different power supply arrangement.
If voltage adjustment is required, use the integrated potentiometer and a suitable measuring instrument. Adjust the output only within the specified 24–28.8 V range, and confirm that the selected voltage is acceptable for all connected equipment.
After wiring inspection, energize the unit and measure the output voltage. Check the green 24 V OK LED and verify the relay status signal where it is integrated into the control system.
Finally, connect the intended load and monitor the output under normal operating conditions.
Power supply faults can affect an entire control cabinet or machine. Before replacing the unit, inspect the input source, wiring, load demand, and status indications.
| Symptom | Possible Cause | Recommended Action |
|---|---|---|
| No 24 V DC output | Missing input supply or incorrect input wiring | Measure the DC input and inspect input connections |
| Output voltage is too low | Excessive load or unsuitable input voltage | Check the load current and confirm the input is within range |
| Output voltage fluctuates | Unstable input or changing load conditions | Inspect the upstream DC source and connected equipment |
| 24 V OK LED is off | Output voltage not within the normal status range | Measure the output and review the unit’s diagnostic information |
| Relay status signal is incorrect | Output fault or external signal wiring issue | Check the output voltage and relay circuit connections |
| Unit becomes unusually hot | High load, restricted ventilation, or excessive ambient temperature | Check load demand, cabinet ventilation, and temperature conditions |
| Output shuts down under load | Overload or short circuit | Isolate the load and inspect downstream wiring |
| Equipment resets intermittently | DC voltage drop or poor connections | Inspect terminal tightness, cable sizing, and load distribution |
Electrical inspection and replacement should be performed by qualified personnel following the site’s isolation and safety procedures.
1. What is the Siemens 6AG2333-0SB00-4AY0?
It is a SIPLUS PS PSU2600 24V/5A TX RAIL stabilized power supply designed to convert a higher-voltage DC input into a regulated 24 V DC output.
2. Does this power supply use an AC or DC input?
It uses a DC input. Its nominal input voltage is 110 V DC, with a specified input range of 77–154 V DC. It should not be treated as a conventional AC-input power supply.
3. What is the rated output of the PSU2600?
The rated output is 24 V DC at 5 A, providing a nominal output power of 120 W.
4. Can the output voltage be adjusted?
Yes. The output can be adjusted through the integrated potentiometer within the specified range of 24–28.8 V DC. The selected voltage must remain suitable for the connected equipment.
5. What is the purpose of the TX RAIL designation?
It identifies the specialized SIPLUS version intended for demanding railway-related environmental applications. The product features conformal coating and extended environmental capabilities.
6. What is the operating temperature range?
The specified operating range is -40 to +70 °C under the applicable conditions. Higher-temperature short-duration operation has specific restrictions and should be checked in the manufacturer’s documentation.
7. How is the unit installed?
It is designed for DIN rail mounting and uses screw terminal connections. Installation must follow the specified mounting, wiring, and ventilation requirements.
8. Does the power supply provide status monitoring?
Yes. It includes a green LED for 24 V OK indication and a relay contact for output status signaling. The relay contact rating and wiring requirements should be checked before integration.
9. What should be checked if the 24 V output disappears?
Check the input DC supply, wiring polarity, protective devices, downstream load, and possible short circuits. Measure the output after isolating suspected faulty loads.
10. What are the dimensions and weight of this model?
The supplied dimensions are 135 × 135 × 60 mm, and the weight is 0.5 kg.
The Siemens 6AG2333-0SB00-4AY0 SIPLUS PS PSU2600 24V/5A TX RAIL is a specialized DIN rail power supply for applications requiring regulated 24 V DC power from a higher-voltage DC source. Its 5 A rated output, adjustable voltage, status monitoring, and conformal-coated construction make it suitable for compatible industrial and railway-related installations.
When selecting or replacing this unit, engineers should pay particular attention to its 110 V DC nominal input, temperature-dependent output capacity, mounting requirements, and environmental operating conditions. Correct load calculation, wiring inspection, and commissioning checks help maintain dependable power delivery to connected automation equipment.