| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The HIMA K7214 (996721402) Fuse and Power Distribution Module is an industrial control-system component associated with power distribution and circuit protection within a modular control assembly. Its role is to support the distribution of electrical power to designated circuits while providing fuse-based protection according to the installed system configuration.
In industrial control cabinets, power distribution components help organize electrical supply paths for control electronics and associated modules. Fuses protect designated circuits against overcurrent conditions, while the distribution arrangement keeps power connections aligned with the cabinet’s electrical design.
The K7214 should be identified by its complete model and part number when planning maintenance or replacement. The exact supply ratings, fuse specifications, terminal assignments, and compatible system configurations must be established from the applicable hardware documentation rather than inferred from the product name alone.
| Parameter | Specification |
|---|---|
| Manufacturer | HIMA |
| Model | K7214 |
| Part Number | 996721402 |
| Product Type | Fuse and Power Distribution Module |
| Dimensions | 350 × 80 × 150 mm |
| Weight | 0.8 kg |
The K7214 distributes a 24 V DC or 48 V DC supply to individual branch circuits within an industrial control cabinet. Its current distribution arrangement accommodates up to 18 individual circuits, with a maximum aggregate current of 150 A.
The basic power path is:
24/48 V DC Power Supply → K7214 Current Distribution Board → Individual Branch Circuits → Connected Equipment
Each branch supplies its assigned load according to the cabinet’s electrical design. The total current drawn by all connected circuits must remain within the board’s aggregate current limit, while each branch must have appropriate protection for its wiring and connected equipment.
When a circuit loses power, troubleshooting should begin with the incoming supply, branch protection, terminal connections, and downstream load. The board’s current rating does not mean that every individual circuit can carry 150 A. Branch-circuit ratings depend on the installed protective devices, wiring, and applicable system requirements.
For replacement work, engineers should confirm the DC supply voltage, total load, number of required circuits, mounting arrangement, and protection configuration before installing the board.
The K7214 serves as a centralized DC current distribution component within an industrial control cabinet. It supplies individual circuits that power compatible control-system equipment and associated electrical loads.
24/48 V DC Supply → K7214 Distribution Board → Protected Branch Circuits → Control Equipment
| System Element | Function |
|---|---|
| HIMA K7214 | Distributes DC power across individual circuits |
| DC Power Supply | Provides the 24 V DC or 48 V DC input |
| Branch-Circuit Protective Devices | Protect individual circuits according to their specified ratings |
| Distribution Wiring | Carries power from the board to connected loads |
| Control Modules | Consume electrical power for their assigned functions |
| Cabinet Grounding and Protection | Supports the electrical safety arrangement required by the installation |
| Application | Typical Use |
|---|---|
| Process Automation Cabinets | Distributing DC power to multiple control circuits |
| Safety-System Installations | Supplying designated circuits in a compatible HIMA system configuration |
| Industrial Control Panels | Consolidating power distribution for control equipment |
| Power Generation Facilities | Organizing DC supply branches within plant control cabinets |
| Chemical and Petrochemical Plants | Supporting distributed control-circuit power requirements |
| Control-System Maintenance | Replacing a distribution board after verifying supply and load requirements |
| Plant Modernization | Reviewing circuit capacity and protection when updating an existing cabinet |
| Component | Function |
|---|---|
| 24 V DC Power Supply | Provides the lower-voltage DC supply option |
| 48 V DC Power Supply | Provides the alternative DC supply option |
| Branch-Circuit Protective Devices | Protect individual outgoing circuits |
| DC Distribution Wiring | Carries power to the connected loads |
| Industrial Control Modules | Use the distributed power for their designated functions |
| Control Cabinet Mounting System | Supports the board within the electrical assembly |
| Model | Product Type | Selection Consideration |
|---|---|---|
| HIMA K7213 | Redundant Infeed / Current Distribution Component | Verify the infeed arrangement and circuit configuration before comparison |
| HIMA K7215 | Current Distribution Board with Monitoring Functions | Consider where additional distribution monitoring is required |
| HIMA K7217 | Fuse and Power Distribution Module | Supports up to 30 individual circuits; verify mounting, protection, and system compatibility before considering an upgrade |
The K7214 is specified for 24/48 V DC distribution. The selected supply voltage and all connected equipment must be compatible with the actual installation configuration.
No. The 150 A figure refers to the maximum aggregate current capacity of the distribution board. Individual circuit limits depend on the installed protection, wiring, and connected loads.
The K7214 supports up to 18 individual circuits. The actual number used depends on the cabinet’s distribution design and the required protective-device arrangement.
Compare the supply arrangement, circuit count, mounting requirements, protective devices, and system compatibility. The K7217 supports up to 30 individual circuits, but its greater circuit capacity alone does not establish that it is a direct replacement.