Brand: HIMA
Series: Safety‑Related Input Modules / Digital Input Modules, part of HIMA HIMatrix / F‑series safety modules
The HIMA F3237 (Part Number 984323702) is a safety‑related digital input module designed for industrial safety systems requiring high diagnostic coverage, fast response, and compliance with functional safety standards. It is intended to receive discrete/digital input signals from sensors (e.g. NAMUR proximity switches, resistor‑wired sensors) in safety‑critical environments such as process control, oil & gas, power generation, and transportation. The module performs continuous self‑diagnostics including detection of line breaks, short circuits, cross‑talk, filter function checks, and channel fault indications. It is built to be robust, reliable, and to integrate into safety instrumented systems (SIS) or safety controllers.
Here are the technical parameters of HIMA F3237:
| Parameter | Specification |
|---|---|
| Model | F3237 (Part No. 984323702) |
| Number of Input Channels | 8 channels |
| Input Signal Type | Digital (NAMUR / resistor‑wired sensors) |
| Input Voltage (Supply / Us) | ~ 8.2 V DC (for sensor supply) |
| Operating Signal / Current (for “0” and “1”) | “0” signal: 0.35 mA ≤ Ie ≤ 1.2 mA; “1” signal: 2.1 mA ≤ Ie ≤ 6.0 mA |
| Wire Break Detection Threshold | ≤ 0.28 mA |
| Short‑Circuit Detection Threshold | ≥ 6.5 mA |
| Line Impedance | ≤ 50 Ω (per DIN 19234) |
| Maximum Line Length | ≤ 1000 m (wire cross‑section ~0.5 mm²) |
| Response Time | approx. 10 ms |
| Diagnostic Coverage | ~100 % coverage of defined failure modes |
| Safety Integrity Level (SIL) | SIL 3 |
| Explosion/ATEX Rating | II 3G Ex nA IIC T4 (i.e. suitable for certain hazardous atmospheres) |
| Power Consumption | 5 V DC: ~ 90 mA; 24 V DC: ~ 170 mA |
| Operating Temperature | 0 °C to +50 °C (some installations may accept broader ranges under specified conditions) |
| Storage Temperature | −40 °C to +85 °C |
| Dimensions (L × W × H) | approx. 110 mm × 30 mm × 120 mm |
| Weight | approx. 0.25 kg |
Here are the main advantages and distinguishing features of HIMA F3237:
High diagnostic coverage: The module continuously self‑checks for wire breaks, shorts, cross‑talk, filter function, channel faults, etc. This reduces hidden failures and increases reliability.
Safety integrity: Certified to SIL 3, compliant with international standards for functional safety.
NAMUR compatibility: Works with standard proximity switches and resistor‑wired sensors following DIN 19234, so easier integration with existing sensor infrastructure.
Short line and long line capability: Allows long cable runs (up to 1000 m with 0.5 mm²) with acceptable line impedance (≤ 50 Ω), giving flexibility in sensor placement.
Fast response time (~10 ms): Ensures safety system responds promptly to abnormal or dangerous conditions.
Robust detection of fault conditions: Wire breaks, shorts, low or high currents etc. will trigger diagnostic or shutdown responses.
Compact and moderate power consumption: For safety modules with many diagnostic features, the power draw is reasonable and physical size modest.
Typical use‑cases for HIMA F3237 include:
Emergency Shutdown Systems in oil & gas platforms or refineries: to monitor safety sensors and trigger safe shutdowns.
Fire & Gas systems: to detect flame sensors, gas detectors, or leak detectors.
Process Control in chemical plants: for safety interlocks based on limit switches or safety‑rated sensors.
Power generation (thermal, hydroelectric etc.): for turbine overspeed protection, burner safety, boiler safety interlocks.
Manufacturing & Automation: safety door switches, light curtains, emergency stop circuits, guarding in robotics.
Transportation infrastructure: railway signalling safety, switchgear protection, etc.
Any system requiring compliance with SIL 3 and with near real‑time detection of sensor faults or failures for safe operation.
Here are recommended models that are either in the same series / similar function or popular within the HIMA brand. I classify into two groups: “Same series / related functionality” and “Other popular HIMA modules”.
These are modules close in function to the F3237 (digital input / safety‑related input modules etc.):
| Model | Channels / Function | Key Specs / Notes |
|---|---|---|
| F3236 | Digital input module, similar safety related input; likely 8 channels with diagnostics; works with NAMUR sensors etc. | |
| F6208 | Analog input module (8 channels); for safety rated analog measurement (e.g. 4‑20 mA) | |
| F6214 | Digital input / digital interface module; safety‑rated, may differ in channel count or response time | |
| F6215 | Similar family; safety input module with extended diagnostics or possibly different wiring / input ranges | |
| F3311 | Higher‑precision analog input module; when analog measurement rather than digital detection is required in safety system |
These are well‑used modules in HIMA product line but for different parts of safety system (controllers, outputs, communication etc.):
| Model | Function / Role | Key Specs / Notes |
|---|---|---|
| F8627X | Safety Controller / CPU unit; executes safety logic, interfaces to I/O and field networks | |
| F8650X | I/O expansion or safety controller extension; supports many input / output modules, mixed analog/digital | |
| F3330 | Digital output module; drives safety actuators / relays etc. | |
| K9203 | Communication / interface module; for bridging safety system to other networks or systems | |
| F6217 | Analog input module; for safety‑related analog signals, complementing digital input modules like F3237 |
Below are ten common questions (Q) and answers (A) about HIMA F3237, in clear format:
Q1: What kind of sensors can be connected to F3237?
A1: NAMUR proximity switches and resistor‑wired sensors compliant with DIN 19234.
Q2: What happens in case of wire break in the sensor line?
A2: The module detects wire break (below the threshold of ≤ 0.28 mA) and triggers a diagnostic/fault condition.
Q3: What is the threshold for short‑circuit detection?
A3: If input current exceeds ~ 6.5 mA, the module recognises this as a short‑circuit condition.
Q4: What response time can be expected?
A4: Approximately 10 milliseconds from input change to detection / module reaction.
Q5: What are the operating voltage / supply requirements?
A5: The module uses ~ 8.2 V DC for sensor supply; main supply also may include 24 V DC. Power consumption is ~ 90 mA at 5 V, ~ 170 mA at 24 V.
Q6: What is the operating temperature range?
A6: Regular specified range is about 0 °C to +50 °C; storage from −40 °C to +85 °C.
Q7: How many input channels does F3237 support?
A7: It supports 8 digital input channels.
Q8: Can it detect cross‑talk between channels?
A8: Yes. It includes diagnostics for cross‑talk of the input circuits and ensures channels do not interfere.
Q9: What is the line impedance and its significance?
A9: ≤ 50 Ω per the DIN 19234 standard; if impedance is too high, signals may degrade or diagnostics may be less accurate.
Q10: What is the module’s physical size and weight?
A10: Approximate dimensions are 110 mm × 30 mm × 120 mm, and weight about 0.25 kg.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.