• GE IS215VCMIH2CA Mark VI VME Communications Interface Board
  • GE IS215VCMIH2CA Mark VI VME Communications Interface Board
  • GE IS215VCMIH2CA Mark VI VME Communications Interface Board
  • GE IS215VCMIH2CA Mark VI VME Communications Interface Board
Product Overview The GE IS215VCMIH2CA is a Mark VI VME Communications Interface Board used in GE Speedtronic Mark VI control systems. The board belongs to the VCMI communication hardware used within the……
GE IS215VCMIH2CA Mark VI VME Communications Interface Board
  • GE
  • IS215VCMIH2CA
  • VME Communications Interface Board
  • USA
  • 340 × 220 × 25 mm
  • 1.2 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

GE IS215VCMIH2CA Mark VI VME Communications Interface Board

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IS215VCMIH2CA Mark VI VME Communications Interface Board

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IS215VCMIH2CA Mark VI VME Communications Interface Board

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IS215VCMIH2CA Mark VI VME Communications Interface Board

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IS215VCMIH2CA is a Mark VI VME Communications Interface Board used in GE Speedtronic Mark VI control systems. The board belongs to the VCMI communication hardware used within the VME-based architecture and supports data exchange between system boards and connected communication paths.

In a Mark VI control cabinet, the VCMI board works alongside the main controller, I/O boards, and other VME modules. Its communication role allows control and system data to move between the internal VME structure and supported external interfaces.

The IS215VCMIH2CA functions as communication infrastructure rather than the primary turbine control processor. Its application is therefore centered on system-level data exchange, board-to-board communication, and connection with associated Mark VI hardware.


Technical Specifications

Parameter Specification
Product IS215VCMIH2CA
Product Type VME Communications Interface Board
Functional Acronym VCMI
Series Mark VI
Control Platform GE Speedtronic Mark VI
Board Architecture VME
Board Function Communications Interface
Network Communication Ethernet / IONet
Serial Communication RS-232C
Communication Processing Onboard processing circuitry
PCB Construction Conformal-coated circuit board
Dimensions 340 × 220 × 25 mm
Weight 1.2 kg

Product Features

  • Mark VI VME communication architecture
  • VCMI communication interface function
  • Supports communication between Mark VI system hardware
  • VME-based board architecture
  • Ethernet / IONet communication capability
  • RS-232C serial communication capability
  • Onboard communication processing
  • Suitable for GE Speedtronic Mark VI control cabinets
  • Conformal-coated circuit board construction

Working Principle

The IS215VCMIH2CA processes communication data exchanged within the Mark VI control architecture. Information received through supported communication interfaces is handled by the board’s communication circuitry before being transferred to the appropriate system hardware.

The VME backplane provides the internal communication path between the VCMI board and other boards installed in the Mark VI rack. This arrangement allows the controller, I/O boards, and communication hardware to exchange system data through the same modular architecture.

External communication paths can be used to exchange information with connected devices. The VCMI handles the communication processing while the main Mark VI controller remains responsible for executing the primary control logic.


Role in a GE Mark VI VME Control Architecture

System Position Function
Mark VI Controller Executes primary turbine control logic
VME Backplane Provides communication between installed VME boards
IS215VCMIH2CA Provides the VME communication interface
IONet Supports communication between control and I/O equipment
Mark VI I/O Boards Handle process signal acquisition and output
External Devices Exchange data through supported communication interfaces

Industrial Applications

Application Typical Use
Gas Turbine Control Communication between turbine control hardware and I/O equipment
Steam Turbine Control Data exchange within Mark VI control cabinets
Generator Control Communication between control and monitoring equipment
Power Generation Integration of VME-based control and communication hardware
Turbine Auxiliary Systems Communication with supporting control equipment
Mark VI Control Cabinets Internal board communication and external device interfacing

Installation and Maintenance

  1. Verify the IS215VCMIH2CA identification before installation and confirm that it matches the required Mark VI hardware.
  2. Disconnect system power and follow the applicable electrical safety procedures before removing or installing the board.
  3. Inspect the VME rack and backplane connection for contamination, damaged contacts, or loose hardware.
  4. Examine the board for overheating, corrosion, damaged components, or cracked solder joints.
  5. Confirm that the board is correctly aligned with the intended VME installation position.
  6. Insert the board evenly and ensure that the backplane connector is fully seated.
  7. Inspect Ethernet, RS-232C, and other communication cables before reconnecting them.
  8. Check communication connectors for loose contacts, damaged pins, or physical damage.
  9. Restore system power according to the approved Mark VI startup procedure.
  10. Check system diagnostics and communication status after startup.
  11. If communication faults occur, inspect the VME connection, network cabling, connected equipment, and system configuration before replacing the board.
  12. When replacing the VCMI board, compare its identification and revision information with the existing hardware before commissioning the replacement.

Related Components

Component Function
Mark VI Controller Provides primary control-system processing
VME Backplane Connects the VCMI board with other VME modules
Mark VI I/O Boards Handle process input and output functions
IONet Network Provides communication between control and I/O hardware
RS-232C Devices Support compatible serial communication
Mark VI Control Cabinet Houses the VME control and communication hardware

Recommended Related Models

Model Product / Function
IS215VCMIH2B Mark VI VME Communications Interface Module
IS215VCMIH2BB Mark VI VME Communications Interface Module
IS215VCMIH2BC Mark VI VME Communications Interface Board
IS215VCMIH2BE Mark VI VME Communications Interface Board
IS215VCMIH1B Mark VI VME Communications Interface Module

Key Advantages

  • VME-based Mark VI communication architecture
  • Supports system-level data exchange
  • Ethernet and serial communication capability
  • Dedicated communication interface
  • Onboard communication processing
  • Suitable for modular turbine control systems

Technical FAQs

What is the main function of the IS215VCMIH2CA?

The IS215VCMIH2CA functions as a VME Communications Interface Board within the GE Mark VI control architecture. It supports communication between the VME-based system hardware and connected communication interfaces.

Is the IS215VCMIH2CA a primary turbine controller?

No. The board handles communication interface functions rather than primary turbine control. The main control logic is executed by the appropriate Mark VI controller.

How does the IS215VCMIH2CA fit into the Mark VI VME architecture?

The board operates as part of the VME communication structure and works with the VME backplane, controller, I/O boards, and supported network or serial communication paths.

What should be checked before replacing an IS215VCMIH2CA?

Verify the board identification, revision information, VME installation position, backplane connection, and communication cabling against the existing system before commissioning the replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501