The Allen-Bradley 1757-BEM ProcessLogix Battery Extension Module is a dedicated backup power component designed for Rockwell Automation ProcessLogix controller systems. Its primary function is to provide battery backup power to volatile memory in compatible ProcessLogix modules, helping preserve important information such as controller configuration databases during temporary power interruptions.
Unlike a standard PLC power supply or communication module, the 1757-BEM is specifically designed to extend memory backup capability. It connects directly to the ProcessLogix chassis backplane and supplies backup power to compatible memory circuits when normal controller power is unavailable.
The module uses a rechargeable nickel-cadmium (NiCd) battery pack consisting of three series-connected sub-C cells. When fully charged, the battery system can provide 3.6 V DC at 5 mA for up to 240 hours under the specified conditions.
The 1757-BEM also incorporates battery monitoring functions, including periodic battery-presence and load tests. A front-panel indicator provides local battery status information, while relay contacts allow battery condition to be monitored remotely.
This functionality makes the module particularly important in ProcessLogix installations where retaining controller configuration information during power interruptions is essential.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Manufacturer | Rockwell Automation |
| Model | 1757-BEM |
| Product Family | ProcessLogix |
| Product Type | Battery Extension Module |
| Primary Function | Volatile Memory Backup |
| Battery Type | Nickel-Cadmium (NiCd) |
| Battery Configuration | Three series-connected sub-C cells |
| Battery Output | 3.6 V DC at 5 mA |
| Backup Duration | Up to 240 hours on a full charge |
| Battery Capacity | 200 mAh |
| Backplane Current at 5.1 V DC | 112 mA |
| Backplane Current at 24 V DC | 36 mA |
| Power Dissipation | 1.424 W |
| Thermal Dissipation | 9.6 W |
| Alarm Relay Rating | 30 V DC maximum, 100 mA maximum |
| Chassis Interface | Standard ICP backplane connector |
| Module Width | One standard ICP slot |
| Operating Temperature | 0 to 60°C |
| Storage Temperature | -40 to 85°C |
| Relative Humidity | 5–95%, non-condensing |
| Listed Dimensions | 144.57 × 22 × 105.42 mm |
| Listed Weight | 0.22 kg |
Specification note: The dimensions and 0.22 kg weight above are the supplied product-listing values. Rockwell Automation’s installation documentation identifies the 1757-BEM as a one-slot-wide ICP module and specifies an approximate weight of 0.35 kg. Confirm the physical measurements and actual unit weight against the product label and applicable documentation before ordering.
The primary purpose of the 1757-BEM is to maintain backup power for volatile memory circuits in compatible ProcessLogix modules, including the 1757-PLX52 controller.
During normal operation, the controller receives power from the system power supply. If normal power is interrupted, the battery extension module provides backup energy to the supported memory circuits.
This helps preserve important stored information, such as configuration databases, during temporary power outages and planned shutdowns.
The 1757-BEM uses three series-connected sub-C nickel-cadmium battery cells. Together, these cells provide a nominal backup output of 3.6 V DC.
The battery pack has a rated sourcing capacity of approximately 200 mAh. Under the specified operating conditions, a fully charged battery can provide 5 mA for up to 240 hours.
The module includes charging circuitry that uses the system’s 24 V DC supply to maintain the battery charge during normal operation.
Battery condition is an important factor in memory backup reliability. The 1757-BEM incorporates self-test circuitry that periodically checks whether the battery pack is present and evaluates its condition under load.
These checks help identify battery deterioration before a backup failure occurs.
The monitoring system provides additional confidence that the battery is available when normal controller power is interrupted.
A front-panel LED provides local information about the battery system’s condition.
The indicator helps maintenance personnel identify potential battery problems during routine inspections. It can also support troubleshooting when the controller reports a battery-related issue.
The module provides relay contacts for external battery-condition monitoring. These contacts can be incorporated into a suitable alarm or monitoring circuit.
This allows maintenance personnel to receive an indication of battery problems without relying exclusively on direct inspection of the module.
The relay contacts are rated for a maximum of 30 V DC and 100 mA. External circuit design must remain within these limits.
The Allen-Bradley 1757-BEM is primarily intended for ProcessLogix installations that require additional battery backup for controller memory.
Process Control Systems
In industrial process facilities, controller configuration information is important for maintaining consistent system operation. The 1757-BEM helps preserve supported volatile memory contents during temporary power interruptions.
Chemical and Petrochemical Plants
Process control systems in chemical and petrochemical facilities may contain important configuration databases and control parameters. Battery backup can help protect supported memory information during planned shutdowns and unexpected power loss.
Manufacturing Facilities
ProcessLogix controllers are used in industrial manufacturing environments to coordinate equipment and process operations. The 1757-BEM provides an additional memory backup function for compatible installations.
Continuous-Operation Facilities
Facilities that operate around the clock may experience planned maintenance shutdowns or temporary power interruptions. The battery extension module helps maintain supported memory information during these events.
Legacy ProcessLogix System Maintenance
The 1757-BEM is also relevant to maintenance and replacement work involving existing ProcessLogix systems. Because this is an older product, engineers should verify its condition, battery status, and compatibility with the installed controller before use.
The 1757-BEM is a single-slot-wide module designed for installation in a compatible ProcessLogix controller chassis. It connects through the standard ICP backplane connector.
Rockwell Automation documentation provides recommended default slot locations:
Confirm the actual chassis configuration and installation requirements before mounting the module.
The module is supplied with the battery uninstalled according to its installation documentation. The correct battery pack must be installed before the module can provide its intended backup function.
Use the specified battery type and follow the manufacturer’s installation procedure. Incorrect battery installation can prevent proper backup operation.
During normal operation, the module uses the system’s 24 V DC supply for battery charging. Verify that the ProcessLogix chassis power supply is operating correctly and that the module receives the required backplane power.
The battery monitoring relay can be connected to a suitable external alarm circuit. Ensure that the connected circuit does not exceed the specified contact rating of 30 V DC and 100 mA.
The alarm arrangement should be checked during commissioning to confirm that battery fault conditions are correctly reported.
After installation, inspect the module seating, battery connection, and chassis backplane interface. Check the front-panel status indicator and verify that the battery monitoring function operates correctly.
For systems where memory retention is critical, confirm that the backup battery is fully charged and that the module is correctly associated with the memory it is intended to protect.
| Problem | Possible Cause | Recommended Action |
|---|---|---|
| Battery status indicator shows a fault | Battery is missing, discharged, or deteriorated | Inspect the battery pack and follow the manufacturer’s replacement procedure |
| Backup function is unavailable | Incorrect battery installation or poor connection | Check battery installation and module connections |
| Battery does not maintain charge | Battery aging or charging supply problem | Inspect the battery condition and verify the 24 V DC supply |
| Remote alarm is activated | Battery monitoring circuit has detected an abnormal condition | Check the front-panel indicator and battery condition |
| Controller memory information is not retained | Backup battery is depleted or the protected memory configuration is incorrect | Verify the battery system and compatible memory connections |
| Module is not recognized | Incorrect chassis installation or backplane connection | Inspect the module seating and chassis compatibility |
The battery is a critical part of the 1757-BEM. Maintenance personnel should periodically inspect its condition and follow the manufacturer’s recommended replacement schedule.
Before removing the module, determine whether it is the active backup source for protected memory. Removing the only available backup source may cause loss of retained information if normal power is interrupted.
Nickel-cadmium batteries must be handled and disposed of according to applicable environmental and safety regulations. Do not short-circuit, disassemble, or dispose of battery cells with ordinary waste.
1. What is the Allen-Bradley 1757-BEM?
The 1757-BEM is a ProcessLogix Battery Extension Module designed to provide backup power for volatile memory in compatible ProcessLogix controller modules.
2. What is the main purpose of the 1757-BEM?
Its main purpose is to help preserve important memory information, such as controller configuration databases, during temporary power interruptions.
3. What type of battery does the module use?
It uses three series-connected sub-C nickel-cadmium battery cells.
4. What is the backup voltage of the 1757-BEM?
The battery system provides 3.6 V DC at a rated output current of 5 mA.
5. How long can the battery provide backup power?
A fully charged battery can provide the specified 3.6 V DC at 5 mA for up to 240 hours under the manufacturer’s stated conditions.
6. Does the module support battery condition monitoring?
Yes. It includes battery-presence and load-test functions, a front-panel status indicator, and relay contacts for remote alarm monitoring.
7. Where is the 1757-BEM installed?
It is installed in a compatible ProcessLogix controller chassis through a standard ICP backplane connector. Recommended default slots depend on the chassis size.
8. Does the 1757-BEM charge its battery during normal operation?
Yes. Its charging circuit uses the system’s 24 V DC supply to maintain the rechargeable battery during normal operation.
9. Is the 1757-BEM still a current-generation product?
The 1757-BEM is an older ProcessLogix product and is listed as discontinued by product suppliers. Buyers should verify availability, condition, battery health, and compatibility before purchasing.
10. What should be checked before replacing a 1757-BEM?
Check the exact model number, ProcessLogix chassis compatibility, battery condition, module status, and the memory backup requirements of the connected controller. Also confirm whether another valid backup source is available before removing the existing module.
The Allen-Bradley 1757-BEM ProcessLogix Battery Extension Module provides an important memory backup function for compatible ProcessLogix controller systems. Its rechargeable NiCd battery pack supplies 3.6 V DC at 5 mA for up to 240 hours under specified conditions, helping maintain supported volatile memory information during temporary power interruptions.
Additional features include automatic battery monitoring, front-panel status indication, and remote alarm relay contacts. These functions help maintenance teams monitor battery condition and identify potential backup problems.
For industrial facilities maintaining legacy ProcessLogix installations, the 1757-BEM remains a relevant replacement component. Before installation, verify the module’s compatibility, battery condition, chassis requirements, and backup configuration to ensure reliable memory protection.