• GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board
  • GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board
  • GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board
  • GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board
Product Overview The GE IS200TBAOH1CCB is a Mark VI Analog Output Terminal Board used to organize and terminate analog output circuits within a GE Mark VI turbine control system. It forms part of the fi……
GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board
  • GE
  • IS200TBAOH1CCB
  • Analog Output Terminal Board
  • USA
  • 270 × 110 × 30 mm
  • 0.72 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 2

Our advantage

GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IS200TBAOH1CCB Mark VI Analog Output Terminal Board

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IS200TBAOH1CCB is a Mark VI Analog Output Terminal Board used to organize and terminate analog output circuits within a GE Mark VI turbine control system. It forms part of the field-side interface between the Mark VI I/O architecture and analog-controlled devices installed in the turbine or plant.

In a typical Mark VI installation, the control system generates an analog command through its I/O hardware, while field devices such as control elements receive the corresponding signal through cabinet wiring. The IS200TBAOH1CCB provides the terminal interface that organizes these outgoing circuits before they continue toward the field.

This terminal-board arrangement keeps field wiring structured and provides a defined point for connection inspection and troubleshooting. It is suited to established Mark VI turbine control cabinets where analog output circuits need to be terminated and routed in an organized manner.


Technical Specifications

Parameter Specification
Product Model IS200TBAOH1CCB
Product Type Analog Output Terminal Board
Product Family Mark VI
Series GE Mark VI
Manufacturer General Electric
Board Function Analog Output Signal Termination
Signal Type Analog Output Signals
Application Turbine Control and Actuation
System Integration Mark VI Control System
Interface Role I/O and Field Device Interconnection
Signal Path Mark VI I/O → Terminal Board → Field Device
Installation Control Cabinet / I/O Interface
Dimensions 270 × 110 × 30 mm
Weight 0.72 kg

Product Features

  • Provides a dedicated termination interface for analog output circuits in GE Mark VI systems.
  • Organizes outgoing analog signals between Mark VI I/O hardware and field devices.
  • Supports structured routing of control signals within turbine control cabinets.
  • Separates field output wiring from the primary control-processing hardware.
  • Suitable for analog control circuits associated with turbine equipment and plant actuators.
  • Provides an accessible connection point for field wiring inspection and maintenance.
  • Supports established GE Mark VI cabinet wiring architectures.
  • Functions primarily as a termination and interconnection board rather than a standalone controller.
  • Helps technicians trace analog output circuits during commissioning and troubleshooting.

Working Principle

The IS200TBAOH1CCB forms part of the analog output path from the Mark VI control system toward field equipment. The control processor determines the required control action, and the corresponding command is delivered through the Mark VI I/O hardware.

The output signal then reaches the IS200TBAOH1CCB, where the associated field circuit is terminated and routed toward the connected field device. Depending on the application, the receiving device may be an actuator, control element, or other equipment requiring an analog command.

Control processor → Mark VI I/O electronics → IS200TBAOH1CCB → Field wiring → Analog-controlled device

The terminal board primarily handles the physical interface and routing of the output circuits. It does not replace the control logic executed by the Mark VI controller or the I/O functions that generate and manage the analog output signal.

During troubleshooting, the complete signal path can be checked from the control command through the I/O interface, terminal connections, field wiring, and receiving device. This helps distinguish a terminal or wiring issue from a problem in the control or I/O section.


Role in a GE Mark VI Turbine Control Architecture

The IS200TBAOH1CCB occupies the field termination layer of the Mark VI analog output architecture. It provides the connection boundary between the electronic I/O section and external analog-controlled equipment.

System Layer Typical Component Function
Turbine Control GE Mark VI Controller Executes turbine control strategies and output commands
Control Processing Mark VI Control Processor Determines control actions from configured logic and process conditions
I/O Interface Mark VI Analog Output Hardware Generates and manages analog output signals
Termination IS200TBAOH1CCB Terminates and routes analog output field circuits
Field Interface Actuators / Control Devices Receives analog control commands
Turbine Process Gas or Steam Turbine Equipment Responds to the commanded control action

Industrial Applications

Application Board Role
Gas Turbine Control Terminates analog output circuits used for turbine control functions
Steam Turbine Control Organizes analog command wiring between Mark VI I/O and field equipment
Turbine Actuation Provides the field-side connection for analog-controlled devices
Power Generation Supports structured analog output termination in turbine control cabinets
Process Control Routes analog commands from the control system toward field devices
Control System Maintenance Provides an accessible point for output-circuit inspection and tracing
Mark VI System Service Supports replacement and maintenance of existing analog output terminal-board assemblies

Installation and Maintenance

  1. Confirm that the IS200TBAOH1CCB matches the existing Mark VI analog output termination arrangement before installation.
  2. Review the applicable cabinet drawings and field wiring documentation before disconnecting the existing board.
  3. Isolate the relevant control and I/O circuits according to the plant’s electrical safety and maintenance procedures.
  4. Identify and label outgoing field connections before removing the existing terminal-board wiring.
  5. Inspect terminals and board interfaces for contamination, corrosion, looseness, or physical damage.
  6. Check associated output wiring for damaged insulation, overheating, abrasion, or mechanical stress.
  7. Install the board in the correct cabinet position and maintain the established wiring arrangement.
  8. Ensure all output connections are fully seated and mechanically secured.
  9. Verify every field connection against the applicable Mark VI documentation before energizing the circuit.
  10. Check the corresponding analog output channels for abnormal behavior or unexpected output conditions after installation.
  11. If an output does not reach the field device as expected, trace the circuit from the I/O hardware through the terminal board and field wiring.
  12. Record the installed board model and associated output-circuit wiring for future Mark VI maintenance and troubleshooting.

Related Components

Component Function in the System
GE Mark VI Analog Output I/O Hardware Generates and manages analog output signals
GE Mark VI Controller Executes turbine control logic and output commands
Mark VI Terminal Boards Provide field wiring termination and signal interfaces
Control Valve / Actuator Receives analog control signals from the system
Field Wiring Carries output commands from the terminal interface to the field device
Control Cabinet Houses terminal, I/O, and control hardware
Turbine Control Equipment Responds to analog commands generated by the Mark VI system

Recommended Related Models

Model Product Type Typical Relationship
GE IS200TBAOH1A Mark VI Analog Output Terminal Board Related Mark VI analog output terminal-board configuration
GE IS200TBAOH1B Mark VI Analog Output Terminal Board Related analog output terminal-board model
GE IS200TBAOH1C Mark VI Analog Output Terminal Board Related Mark VI analog output interface board
GE IS200TBAIH1C Mark VI Analog Input Terminal Board Complementary Mark VI analog input termination board
GE Mark VI Analog Output I/O Modules Analog Output I/O Hardware Associated I/O hardware for analog output circuits

Key Advantages

  • Provides an organized termination point for Mark VI analog output field wiring.
  • Maintains a structured boundary between I/O electronics and field devices.
  • Supports clear identification and routing of analog control circuits.
  • Facilitates inspection and troubleshooting of output connections.
  • Fits established GE Mark VI turbine control cabinet architectures.
  • Useful for maintenance and replacement of existing analog output terminal-board assemblies.

Technical FAQs

What is the primary function of the IS200TBAOH1CCB?

The IS200TBAOH1CCB serves as an analog output terminal and interface board within a GE Mark VI system. It provides the physical connection between Mark VI analog output circuits and the associated field devices.

Does the IS200TBAOH1CCB generate the analog output signal?

The terminal board should be treated primarily as a termination and routing component. The associated Mark VI analog output I/O hardware handles the electronic output function, while the terminal board provides the field-side connection.

What should be checked if a field actuator does not respond to an analog command?

The control command, associated I/O channel, terminal-board connections, field wiring, and receiving device should be checked in sequence. This helps determine whether the issue is located in the control system, I/O interface, terminal connection, or field circuit.

Why is an analog output terminal board useful in a Mark VI system?

It provides a structured connection point between the electronic I/O section and field equipment. This simplifies cabinet wiring organization and gives maintenance personnel a defined location for checking and tracing analog output circuits.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501