Product Overview The GE IS200TBAIH1CDC is a Mark VI Analog Input Terminal Board used to terminate and organize analog field signals within a GE Mark VI turbine control system. It forms part of the cabin……
GE IS200TBAIH1CDC Mark VI Analog Input Terminal Board
  • GE
  • IS200TBAIH1CDC
  • Analog Input Terminal Board
  • USA
  • 330.2 × 20 × 101.6 mm
  • 0.9 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 1

Our advantage

GE IS200TBAIH1CDC Mark VI Analog Input Terminal Board

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IS200TBAIH1CDC Mark VI Analog Input Terminal Board

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IS200TBAIH1CDC Mark VI Analog Input Terminal Board

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IS200TBAIH1CDC Mark VI Analog Input Terminal Board

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IS200TBAIH1CDC is a Mark VI Analog Input Terminal Board used to terminate and organize analog field signals within a GE Mark VI turbine control system. It forms part of the cabinet-level interface between field instrumentation and the system’s analog I/O hardware.

In a typical turbine control installation, transmitters and other process instruments send measurement signals through field wiring into the control cabinet. The IS200TBAIH1CDC provides the termination point for these circuits and routes the associated connections toward the Mark VI I/O electronics.

The board is suited to established Mark VI installations where analog instrumentation must be arranged in a structured and maintainable cabinet architecture. Its role is focused on field termination and signal interconnection rather than control logic or primary signal processing.


Technical Specifications

Parameter Specification
Product Model IS200TBAIH1CDC
Product Type Analog Input Terminal Board
Product Family Mark VI
Series GE Mark VI
Manufacturer General Electric
Board Function Analog Input Signal Termination
Signal Type Analog Field Signals
Application Turbine Control and Monitoring
System Integration Mark VI Control System
Interface Role Field Wiring and I/O Interconnection
Signal Path Field Instrument → Terminal Board → Mark VI I/O
Installation Control Cabinet / I/O Interface
Dimensions 330.2 × 20 × 101.6 mm
Weight 0.9 kg

Product Features

  • Provides a dedicated termination interface for analog input field wiring in GE Mark VI systems.
  • Organizes incoming instrumentation connections before they reach the associated I/O hardware.
  • Supports structured analog signal routing within turbine control cabinets.
  • Separates field wiring termination from the primary control and processing hardware.
  • Suitable for analog measurement circuits used in turbine control and monitoring.
  • Provides an accessible interface for wiring inspection and maintenance.
  • Supports integration into established Mark VI cabinet architectures.
  • Functions primarily as a termination and interconnection board.
  • Helps simplify tracing of analog field circuits during service activities.

Working Principle

The IS200TBAIH1CDC forms part of the analog input signal path between field instrumentation and the Mark VI control system. A field transmitter or sensor produces a process measurement, and the corresponding electrical signal travels through the plant’s field wiring toward the control cabinet.

The signal is terminated at the IS200TBAIH1CDC, where the field connection is organized and routed toward the associated Mark VI I/O interface. The I/O hardware then acquires the signal for use by the control system.

Field transmitter / sensor → Field wiring → IS200TBAIH1CDC → Mark VI I/O electronics → Control processor

The terminal board itself is not the primary control processor. Its function is centered on physical termination and signal interconnection, making it part of the boundary between field instrumentation and electronic I/O processing.

During troubleshooting, this signal path provides a logical sequence for checking an abnormal measurement. Technicians can work from the field device through the wiring and terminal connections toward the I/O hardware to determine where the expected signal is interrupted or degraded.


Role in a GE Mark VI Turbine Control Architecture

The IS200TBAIH1CDC occupies the field termination layer of the Mark VI analog input architecture. It connects plant instrumentation wiring with the corresponding I/O interface while maintaining an organized cabinet-level wiring structure.

System Layer Typical Component Function
Turbine Control GE Mark VI Controller Executes turbine control strategies and system logic
Control Processing Mark VI Control Processor Processes acquired measurements and control information
I/O Interface Mark VI Analog I/O Hardware Acquires incoming analog field signals
Termination IS200TBAIH1CDC Terminates and routes analog input field wiring
Field Instrumentation Transmitters / Sensors Generates process measurement signals
Turbine Process Gas or Steam Turbine Equipment Produces the process variables being monitored

Industrial Applications

Application Board Role
Gas Turbine Control Terminates analog instrumentation signals used by the Mark VI system
Steam Turbine Control Organizes analog measurement connections in the turbine control cabinet
Turbine Monitoring Provides the field-side interface for analog measurement circuits
Power Generation Supports structured analog signal termination within turbine control systems
Process Instrumentation Connects transmitters and sensors with the Mark VI I/O architecture
Control Cabinet Maintenance Provides an accessible point for wiring inspection and circuit tracing
Mark VI System Service Supports replacement and maintenance of established terminal-board installations

Installation and Maintenance

  1. Confirm that the IS200TBAIH1CDC matches the existing Mark VI terminal-board arrangement before installation.
  2. Review the applicable cabinet drawings and field wiring documentation before disconnecting the existing board.
  3. Isolate the relevant control and I/O circuits according to the plant’s electrical safety and maintenance procedures.
  4. Identify and label field connections before removing the existing terminal-board wiring.
  5. Inspect terminals and board interfaces for corrosion, contamination, looseness, or physical damage.
  6. Check associated wiring for signs of overheating, abrasion, or mechanical stress.
  7. Install the terminal board in the correct cabinet position and maintain the established wiring layout.
  8. Ensure field connections are fully seated and mechanically secured.
  9. Verify each connection against the applicable Mark VI wiring documentation before energizing the system.
  10. Check the corresponding analog input channels for abnormal readings, missing measurements, or unexpected signal changes.
  11. If a channel remains abnormal, trace the signal from the field instrument through the wiring and terminal interface to the associated I/O hardware.
  12. Record the installed board model and wiring arrangement for future Mark VI maintenance and troubleshooting.

Related Components

Component Function in the System
GE Mark VI Analog I/O Hardware Acquires and processes incoming analog field signals
GE Mark VI Controller Executes turbine control and monitoring logic
Mark VI Terminal Boards Provide field wiring termination and signal interfaces
Field Transmitter Generates analog process measurement signals
Temperature / Pressure Instrumentation Provides process measurements to the control system
Control Cabinet Houses terminal, I/O, and control hardware
Field Wiring Carries instrumentation signals between process equipment and the terminal interface

Recommended Related Models

Model Product Type Typical Relationship
GE IS200TBAIH1C Mark VI Analog Input Terminal Board Related Mark VI analog input terminal-board configuration
GE IS200TBAIH1B Mark VI Analog Input Terminal Board Related analog input terminal-board model
GE IS200TBAIS1A Mark VI Analog Input Terminal Board Related Mark VI analog input interface board
GE IS200TBAI1CDD Mark VI Analog Input Terminal Board Related terminal-board configuration for analog input circuits
GE Mark VI Analog I/O Modules Analog I/O Hardware Associated acquisition hardware for terminated analog field signals

Key Advantages

  • Provides an organized termination point for Mark VI analog input field wiring.
  • Maintains a structured boundary between field instrumentation and I/O electronics.
  • Supports clear identification and routing of analog measurement circuits.
  • Facilitates inspection and troubleshooting of field connections.
  • Fits established GE Mark VI turbine control cabinet architectures.
  • Useful for maintenance and replacement of existing analog input terminal-board assemblies.

Technical FAQs

What is the role of the GE IS200TBAIH1CDC in a Mark VI system?

The IS200TBAIH1CDC serves as an analog input termination and interface board. It connects incoming field instrumentation wiring with the associated Mark VI I/O architecture.

Where does the analog signal go after reaching the terminal board?

After field wiring reaches the IS200TBAIH1CDC, the corresponding signal is routed toward the associated Mark VI I/O electronics. The I/O hardware acquires the signal and makes the measurement available to the control system.

What symptoms can indicate a problem around the terminal-board connection?

A missing or abnormal analog measurement can result from issues anywhere along the signal path, including field instrumentation, wiring, terminal connections, or associated I/O hardware. Connection inspection and signal tracing should be performed before replacing other system components.

Can the IS200TBAIH1CDC be evaluated independently from the associated I/O hardware?

The terminal board can be inspected for physical condition, connection integrity, and wiring continuity, but proper system-level verification also requires checking the associated field circuit and I/O interface. The terminal board is one part of the complete analog input signal path.