• Yokogawa AAR181-S50 S2 RTD Input Module
  • Yokogawa AAR181-S50 S2 RTD Input Module
  • Yokogawa AAR181-S50 S2 RTD Input Module
  • Yokogawa AAR181-S50 S2 RTD Input Module
Product Overview The Yokogawa AAR181-S50 S2 is a high-precision RTD Input Module used in Yokogawa CENTUM / ProSafe-RS distributed control systems. It is designed for accurate multi-channel temperature m……
Yokogawa AAR181-S50 S2 RTD Input Module
  • Yokogawa
  • AAR181-S50 S2
  • RTD Input Module
  • Japan
  • 107.5 × 130 × 32.8 mm
  • 0.2 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Yokogawa AAR181-S50 S2 RTD Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Yokogawa AAR181-S50 S2 RTD Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Yokogawa AAR181-S50 S2 RTD Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Yokogawa AAR181-S50 S2 RTD Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Yokogawa AAR181-S50 S2 is a high-precision RTD Input Module used in Yokogawa CENTUM / ProSafe-RS distributed control systems. It is designed for accurate multi-channel temperature measurement, converting resistance signals from RTD sensors (such as Pt100) into digital data for process control and monitoring.

This module is widely used in industrial environments requiring reliable temperature acquisition, strong isolation, and stable long-term performance.


Technical Specifications

Parameter Specification
Manufacturer Yokogawa
Model AAR181-S50 S2
Product Type RTD Input Module
System Compatibility Yokogawa CENTUM / ProSafe-RS
Function Temperature signal acquisition (RTD input)
Input Channels 12 isolated channels
Input Type RTD (Pt100, 3-wire typical)
Input Range Resistance-to-temperature conversion
Measurement Current Approx. 1 mA
Input Voltage Range ±5 V
Signal Isolation Channel-to-channel and system isolation
Accuracy High precision industrial temperature measurement
Burn-out Detection Supported
Data Update Cycle ~1 second scan cycle
Communication Backplane interface with controller
Mounting Type Rack-mounted module
Operating Environment Industrial control cabinet
Humidity Range 5%–95% non-condensing
Dimensions 107.5 × 130 × 32.8 mm
Weight 0.2 kg

Function and Working Principle

The AAR181-S50 S2 operates as a temperature signal acquisition and conversion module.

Its core functions include:

  • Receiving resistance signals from RTD sensors
  • Converting resistance values into temperature data
  • Supplying excitation current for RTD measurement
  • Detecting sensor faults such as open circuit (burn-out)
  • Providing electrical isolation to reduce noise interference

It serves as a front-end temperature interface module in DCS systems.


Role in Industrial Control Systems

Within Yokogawa control systems, this module provides:

  • Accurate multi-point temperature monitoring
  • Integration of RTD sensors into centralized DCS control
  • Stable process variable acquisition for control loops
  • High immunity to industrial electrical noise
  • Reliable operation in continuous process environments

Industrial Applications

The AAR181-S50 S2 is widely used in:

  • Power generation plants (boiler & turbine temperature monitoring)
  • Oil and gas processing systems
  • Chemical and petrochemical industries
  • Metallurgy and furnace control systems
  • Industrial HVAC systems
  • General process automation

Installation and System Integration

Recommended installation practices include:

  • Installing in Yokogawa FIO / CENTUM I/O racks
  • Ensuring correct backplane alignment
  • Using proper RTD wiring (2-wire / 3-wire / 4-wire depending design)
  • Applying shielded cables to reduce noise
  • Performing channel calibration during commissioning

Compatible System Components

The AAR181-S50 S2 typically works with:

  • Yokogawa CENTUM controllers
  • RTD sensors (Pt100, Pt1000)
  • Other analog and digital I/O modules
  • Field termination assemblies
  • Industrial monitoring systems

Recommended Alternative Models

Model Type Key Feature Application
AAR181-S50 S2 RTD input module 12-channel isolated temperature input DCS systems
AAR181-H00/K4A00 RTD input module High-precision temperature measurement Process control
AAR145-S50 S1 RTD/POT input module Multi-signal input capability Monitoring systems
AAI543-S53 Analog input module High-accuracy analog acquisition Industrial measurement
AAI835-S53 Analog I/O module Multi-channel signal processing Automation systems

Key Advantages

  • 12-channel isolated RTD input design
  • High accuracy temperature measurement
  • Strong electrical isolation for stability
  • Built-in sensor fault detection (burn-out)
  • Stable long-term industrial operation
  • Seamless integration with Yokogawa DCS systems

Technical FAQs

What is the AAR181-S50 S2 used for?
It is used for high-precision RTD temperature measurement in industrial control systems.

How many channels does it support?
It supports 12 isolated input channels.

What type of sensors does it support?
RTD sensors such as Pt100 (typically 3-wire).

Does it detect sensor failure?
Yes, it supports burn-out detection.


Conclusion

The Yokogawa AAR181-S50 S2 RTD Input Module is a reliable and high-accuracy temperature acquisition device designed for industrial automation systems. With multi-channel isolation, stable measurement performance, and strong integration capability, it is widely used in process control and critical temperature monitoring applications.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501