Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Emerson VE3051C2 DeltaV M-series 2-Wide Power/Controller Carrier is a mounting and connection component used in DeltaV M-series controller assemblies. It provides the physical carrier position for power and controller-related modules while maintaining the required electrical connections through the carrier and system backplane.
In a DeltaV controller cabinet, the carrier forms part of the hardware layer between the controller assembly and the cabinet-level installation. Its 2-wide configuration is suited to compact M-series layouts where controller and power components are installed together within a defined carrier arrangement.
The VE3051C2 is not a standalone controller or power supply. Its function is tied to the modules installed on the carrier, so carrier selection should be considered together with the controller type, power arrangement, adjacent carriers, and overall DeltaV M-series architecture.
| Parameter | Specification |
|---|---|
| Product Model | VE3051C2 |
| Product Family | DeltaV M-series |
| Product Type | 2-Wide Power/Controller Carrier |
| Carrier Width | 2-Wide |
| Application | DeltaV controller and power module mounting |
| Installation Role | Hardware carrier and electrical interconnection |
| Dimensions | 160 × 30 × 120 mm |
| Weight | 0.38 kg |
The VE3051C2 works as a carrier rather than as an independent processing device. Compatible DeltaV M-series modules are mounted on the carrier, while the carrier provides the mechanical support and electrical interconnection required by the assembly.
During operation, the controller module performs control processing and communicates with the DeltaV system through the associated hardware architecture. Power is distributed through the appropriate power arrangement, while the carrier maintains the physical positioning and connection between the installed modules and the surrounding system.
For maintenance, this distinction is important. A controller communication or power fault should not automatically be attributed to the carrier. The carrier, mounted modules, power source, connectors, and upstream system connections should be checked separately when troubleshooting.
| System Element | Function |
|---|---|
| Field Devices | Provide process measurements and receive control outputs |
| DeltaV I/O System | Interfaces field signals with the control system |
| M-series Controller | Executes control logic, process calculations, and module-level control functions |
| VE3051C2 Carrier | Provides the physical mounting and electrical interconnection structure for compatible power/controller modules |
| Power Arrangement | Supplies the required operating power to the installed control hardware |
| DeltaV Network | Connects controllers, I/O, operator stations, and other system-level components |
| Operator Station | Provides process visualization, alarms, diagnostics, and operator commands |
The VE3051C2 sits at the hardware assembly level of the DeltaV architecture. It does not execute control logic itself, but it supports the physical arrangement in which controller and power hardware operates.
| Application | Typical Use |
|---|---|
| Process Control | Mounting and organizing DeltaV controller hardware in process automation cabinets |
| Oil and Gas | Controller hardware installation for continuous process control systems |
| Chemical Processing | Compact M-series control cabinet assemblies |
| Power and Utilities | Structured installation of DeltaV controller and power components |
| Pharmaceutical Manufacturing | Control hardware integration in distributed automation cabinets |
| General Process Automation | Replacement or expansion of compatible DeltaV M-series carrier assemblies |
| Component | Function |
|---|---|
| DeltaV M-series Controller | Executes control logic and manages control functions |
| DeltaV M-series Power Components | Supply operating power to the controller assembly |
| DeltaV I/O Modules | Interface process signals with the control system |
| M-series Carrier Assembly | Provides the mounting and interconnection structure for compatible modules |
| DeltaV Controller Network | Provides communication between control hardware and the wider DeltaV system |
| DeltaV Engineering Station | Used for system configuration, diagnostics, and engineering activities |
| DeltaV Operator Station | Provides process monitoring and operator interaction |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Emerson VE3051C1 | DeltaV M-series 2-Wide Power/Controller Carrier | M-series controller and power hardware installation |
| Emerson VE3051C0 | DeltaV M-series 2-Wide Power/Controller Carrier | Compatible M-series carrier applications |
| Emerson VE3006 | DeltaV M-series MD Plus Controller | Controller processing and system control |
| Emerson VE3007 | DeltaV M-series MX Controller | M-series distributed control applications |
| Emerson VE3008 | DeltaV M-series MQ Controller | M-series control system installations |
| DeltaV M-series I/O | Distributed I/O Hardware | Field signal acquisition and output |
The VE3051C2 is a DeltaV M-series 2-wide Power/Controller Carrier. It provides the mechanical mounting and electrical interconnection structure for compatible controller and power hardware rather than performing control processing itself.
No. The carrier is a hardware assembly component. Control processing depends on the compatible controller module installed on the carrier, while power is supplied through the associated power arrangement.
Start by separating the problem into controller, carrier connection, power, and network areas. Check controller status, power availability, module seating, carrier contacts, adjacent hardware, and DeltaV network connections before replacing the carrier.
Verify the carrier model, installed controller and power modules, physical mounting arrangement, connector condition, and the existing M-series architecture. The replacement should match the hardware configuration rather than being selected only by physical dimensions.