Low Voltage AC Power Input Module
The 3500/15 125840-02 is a low-voltage AC Power Input Module (PIM) designed for use within the 3500 Series machinery protection system. It accepts AC input power in the range of 85–132 VAC, converts it into regulated DC power, and delivers it to the entire rack system to power all installed modules.
The 3500/15 is designed to fit into the left-most slot of the 3500 rack and occupies a half-height form factor. The 125840-02 version is configured for low-voltage AC input, as opposed to high-voltage AC or DC variants. This module supports hot-swapping and can function either as a primary or backup power source, making it ideal for systems requiring redundancy and zero downtime.
| Parameter | Specification |
|---|---|
| Model | 3500/15 125840-02 |
| Form Factor | Half-height slot (left side of rack) |
| Input Voltage Range | 85–132 VAC |
| Input Frequency | 47–63 Hz |
| Power Consumption | ~3.5 W typical |
| Output | Regulated DC to internal rack modules |
| Redundancy Support | Yes (Primary/Backup configuration) |
| Hot-Swappable | Yes (when backup module is present) |
| Operating Temperature | –30°C to +65°C |
| Storage Temperature | –40°C to +85°C |
| Humidity | Up to 95%, non-condensing |
| Weight | 1.5 kg |
| Dimensions (H × W × D) | 152 mm × 102 mm × 203 mm |
| Mounting | 3500 rack slot (left-most) |
| Cooling | Passive |
| Certifications | Complies with industrial EMC & safety standards |
Turbine Monitoring Systems in power plants
Oil & Gas machinery protection racks
Compressor and Pump Monitoring in petrochemical environments
Manufacturing facilities requiring 24/7 rotating equipment health tracking
Industrial automation racks needing stable low-voltage power
Systems where hot-swapping of modules is essential for uptime
Installations with low-voltage power availability (e.g., 120 V regions)
✅ Low-Voltage AC Compatibility – Designed for 85–132 VAC power grids
✅ Redundancy Ready – Works seamlessly in dual-supply configurations
✅ Compact Form Factor – Half-height design conserves rack space
✅ High Reliability – Wide operating temperature range and humidity tolerance
✅ Hot-Swappable – Can be removed or replaced without shutting down the rack
✅ Energy Efficient – Low power consumption with passive cooling
✅ Fully Integrated – Powers all modules in a 3500 rack with regulated DC
Series: 3500 Machinery Protection System
Product Type: Power Input Module
Module Role: Supplies power to the rack system
Form Factor: Half-height slot module
Brand: Industrial condition monitoring and protection systems manufacturer
(Name intentionally excluded as per request)
| Model | Description |
|---|---|
| 3500/15 125840-01 | High-voltage AC input version (175–264 VAC) |
| 3500/15 (Universal AC) | Universal AC input model for 85–264 VAC compatibility |
| 3500/15 DC High Voltage | DC input module designed for 88–140 VDC power sources |
| 3500/15 DC Low Voltage | DC input module supporting 20–30 VDC |
| 3500/15 Redundant Kit | Matched secondary module for dual power configurations |
| Model | Function |
|---|---|
| 3500/92 | Communication Gateway Module (Modbus/Ethernet) |
| 3500/60 | Proximitor Monitor for shaft displacement |
| 3500/94 | VGA Display Module for rack visualization |
| 3500/42 | Proximitor/Seismic Monitor (combo input module) |
| 3500/22 | Transient Data Interface (TDI) module |
Q1: What does the 3500/15 125840-02 module do?
A1: It converts low-voltage AC (85–132 VAC) into regulated DC power for the 3500 rack and modules.
Q2: Where is it installed in the rack?
A2: It goes into the left-most slot of the 3500 rack and takes up a half-height slot.
Q3: Can it be hot-swapped?
A3: Yes, but only if a redundant (backup) module is installed and active.
Q4: What regions is the low-voltage version suitable for?
A4: It’s ideal for countries and facilities using 110–120 V AC mains power.
Q5: Does it support redundant operation?
A5: Yes. You can install two PIMs—one as primary, one as backup.
Q6: What is the difference between 125840-02 and 125840-01?
A6: The 02 model supports low-voltage AC, while 01 supports high-voltage AC.
Q7: How much power does it typically draw?
A7: Around 3.5 watts under normal operation.
Q8: What are its environmental limits?
A8: Operating temperature from –30°C to +65°C, up to 95% humidity (non-condensing).
Q9: How heavy is the module?
A9: It weighs approximately 1.5 kg.
Q10: Is the module CE or EMC certified?
A10: Yes, it complies with industrial safety and electromagnetic compatibility standards.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.