| 15980777398 |

The 330851-01-000-070-10-01-00 is a compact eddy current proximity probe assembly designed for high-accuracy, non-contact measurement of shaft vibration, axial displacement, and rotor movement in rotating machinery systems.
This configuration belongs to an extended NSv probe variant, optimized for stable signal output and reliable operation in compact industrial installations. It is commonly used in continuous machinery protection systems where precise shaft position tracking is required under harsh operating environments.
The system works by generating a high-frequency electromagnetic field at the probe tip. Any change in distance between the probe and a conductive metal target produces a proportional change in coil impedance, which is converted into a stable voltage signal for monitoring and diagnostics.
This series is designed for compact machinery applications requiring high sensitivity, stable long-term output, and strong environmental resistance.
The 330851-01-000-070-10-01-00 is widely applied in industrial systems such as:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog voltage signal |
| Measurement principle | Eddy current induction |
| Output impedance | Low impedance industrial standard |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (NSv configuration variant) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response |
| Repeatability | Excellent consistency |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +120°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Industrial-grade robustness |
| EMI protection | Strong electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Probe design | Compact NSv miniature type |
| Cable type | Shielded coaxial cable |
| Cable length options | 2 m / 5 m / 10 m |
| Total system weight | ~0.25 kg |
| Probe weight | ~0.06 kg |
| Installation type | Threaded mounting structure |
The system operates based on eddy current induction:
This enables precise non-contact measurement of micro-level shaft motion.
| Parameter | 330851-01-000-070-10-01-00 | 330850-90-000-070-10-01-00 | 330852-01-000-070-10-01-00 | 330853-01-000-070-10-01-00 | 330854-01-000-070-10-01-00 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe |
| Weight (kg) | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg |
| Parameter | 330780-NS-70-10-01 | 330881-28-NS-70-10-01 | 330103-00-NS-70-10-01-00 | 330106-05-NS-70-10-01-00 | 330104-00-NS-70-10-01-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 80×120×35 mm | 110×160×50 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 0.18 kg | 1.9 kg | 0.95 kg | 0.95 kg | 0.95 kg |
| Parameter | 330901-01-70-10-01-00 | 330905-01-70-10-01-00 | 330909-01-70-10-01-00 | 330910-01-70-10-01-00 | 330930-01-70-10-01-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 120×180×60 mm | 100×160×50 mm | 90×140×40 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330851-01-000-070-10-01-00 is an extended NSv eddy current proximity probe designed for precise displacement monitoring in rotating machinery systems. It provides stable long-term performance, high sensitivity, and strong environmental resistance, making it suitable for modern industrial condition monitoring and predictive maintenance applications.