The 330851-01-000-070-10-00-05 is a compact eddy current proximity probe assembly designed for high-precision, non-contact measurement of shaft vibration, axial displacement, and rotor movement in rotating machinery systems.
This model belongs to a compact probe configuration optimized for extended-range installation variants within small-to-medium shaft monitoring applications. It is widely used in continuous condition monitoring systems where reliable displacement feedback is required under harsh industrial operating conditions.
The system operates by generating a high-frequency electromagnetic field at the probe tip. Any variation in the distance between the probe and a conductive metallic surface produces a proportional change in coil impedance, which is converted into a stable voltage signal.
This series is designed for compact machinery applications requiring high sensitivity, stable output, and long-term operational reliability in constrained installation environments.
The 330851-01-000-070-10-00-05 is commonly used in industrial machinery monitoring environments such as:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog voltage signal |
| Measurement principle | Eddy current induction |
| Output impedance | Industrial low impedance design |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (NSv configuration variant) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response |
| Repeatability | Excellent consistency |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +120°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Industrial-grade robustness |
| EMI protection | Strong electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Probe design | Compact NSv miniature type |
| Cable type | Shielded coaxial cable |
| Cable length options | 2 m / 5 m / 10 m |
| Total system weight | ~0.25 kg |
| Probe weight | ~0.06 kg |
| Installation type | Threaded mounting structure |
The system operates based on eddy current induction:
This enables precise non-contact measurement of micro-level shaft movement.
| Parameter | 330851-01-000-070-10-00-05 | 330850-90-000-070-10-00-05 | 330852-01-000-070-10-00-05 | 330853-01-000-070-10-00-05 | 330854-01-000-070-10-00-05 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe |
| Weight (kg) | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg |
| Parameter | 330780-NS-70-10-00 | 330881-28-NS-70-10-02 | 330103-00-NS-70-10-02-00 | 330106-05-NS-70-10-02-00 | 330104-00-NS-70-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 80×120×35 mm | 110×160×50 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 0.18 kg | 1.9 kg | 0.95 kg | 0.95 kg | 0.95 kg |
| Parameter | 330901-01-70-10-02-05 | 330905-01-70-10-02-00 | 330909-01-70-10-02-05 | 330910-01-70-10-02-00 | 330930-01-70-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 120×180×60 mm | 100×160×50 mm | 90×140×40 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330851-01-000-070-10-00-05 is an extended-configuration NSv eddy current proximity probe designed for precise displacement monitoring in rotating machinery. It provides stable long-term performance, strong environmental resistance, and high measurement sensitivity, making it suitable for modern industrial condition monitoring and predictive maintenance systems.