Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

Comprehensive Product Overview & Technical Guide (Offline Version)
The 330103‑080‑00‑05 is an industrial eddy current proximity probe used for non‑contact measurement of vibration, displacement, and shaft position in rotating machinery.
It is part of a family of proximity probes with an 8 mm tip diameter, designed to deliver reliable and accurate measurements for machine condition monitoring and protection.
This model is configured with a specific mechanical and system length combination, optimized for standard installation environments requiring short system length and compact probe housing.
The probe forms part of a complete vibration monitoring system by working in conjunction with a sensing module (proximitor sensor) and appropriate cabling.
The brand is recognized in industry for robust machinery monitoring and protection instruments, with a strong track record of long‑term performance in industrial environments.
Characteristics of the series include:
• Modular design with interchangeable probe, cable, and sensor components
• High sensitivity and low noise measurement
• Stable operation in high vibration and contaminated environments
• Compatibility with widely accepted monitoring systems
| Parameter | Specification |
|---|---|
| Model | 330103‑080‑00‑05 |
| Probe Type | Eddy Current Proximity Probe |
| Probe Diameter | 8 mm |
| Unthreaded Length | 80 mm |
| Case Length | Standard housing |
| System Length | 0.5 m |
| Sensitivity | 7.87 V/mm (typical) |
| Output Type | Analog voltage |
| Frequency Response | 0 – 10 kHz |
| Operating Voltage | -24 V DC (system powered) |
| Operating Temperature | -40 °C to +85 °C |
| Storage Temperature | -50 °C to +100 °C |
| Probe Material | Stainless steel |
| Tip Material | High‑performance polymer |
| Cable Type | Coaxial cable |
| Connector Type | ClickLoc or equivalent locking type |
| Protection Level | IP67 |
| Dimensions (mm) | approx. 180 × 20 × 30 |
| Weight (kg) | approx. 0.35 kg |
The 330103‑080‑00‑05 is engineered for reliable, continuous, real‑time monitoring of rotating shaft movement.
It functions by generating an electromagnetic field around the probe tip. As a conductive surface (shaft) moves within this field, changes are detected and converted into a voltage signal proportional to displacement.
With an 8 mm sensing tip and 80 mm unthreaded length, this model provides good access to shaft surfaces while accommodating standard mounting depths. The 0.5 m system length allows installations where moderate cable routing is needed, such as in compact machinery cabinets.
This configuration makes it suitable for environments with oil, dust, vibration, and temperature changes, without requiring frequent maintenance.
The 330103‑080‑00‑05 probe is widely used in:
• Steam turbines
• Gas turbines
• Centrifugal compressors
• Industrial pumps
• Electric motors
• Gearboxes
Typical monitoring functions include:
• Radial shaft vibration measurement
• Axial displacement detection
• Rotor position tracking
• Speed reference (Keyphasor)
High Measurement Precision
Stable and repeatable readings even in demanding conditions.
Non‑contact Operation
No wear on moving parts, enabling long service life.
Robust Mechanical Design
Operates reliably in oil, dust, and vibration environments.
Compact System Length
Designed for installations with limited cable space.
Modular Compatibility
Works with standard machine monitoring systems and cables.
| Model | Probe Diameter | Cable Length | Case Length | Temp Range | Weight (kg) |
|---|---|---|---|---|---|
| 330103‑00‑05‑05‑02‑00 | 8 mm | 0.5 m | Standard | -40~85 °C | 0.25 |
| 330103‑07‑14‑05‑01‑00 | 8 mm | 0.5 m | 140 mm | -40~85 °C | 0.32 |
| 330103‑07‑16‑05‑02‑00 | 8 mm | 0.5 m | 160 mm | -40~85 °C | 0.34 |
| 330103‑07‑18‑10‑02‑00 | 8 mm | 1 m | 180 mm | -40~85 °C | 0.36 |
| 330103‑00‑05‑50‑02‑00 | 8 mm | 5 m | Standard | -40~85 °C | 0.32 |
| Model | Product Type | Series | Voltage | Output | Dimensions (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| 3300 XL Proximitor Sensor | Proximitor | 3300 XL | 24 V DC | Analog | 120 × 50 × 30 | 0.50 |
| 330180‑91‑00 | Proximitor | 3300 XL | 24 V DC | Analog | 120 × 50 × 30 | 0.48 |
| 330101‑00‑28‑10‑02‑05 | Probe | 3300 XL | -24 V DC | Analog | 150 × 20 × 30 | 0.28 |
| 330100‑50‑05 | Proximitor | 3300 Series | 24 V DC | Analog | 120 × 50 × 30 | 0.45 |
| 3300/65 Monitor | Monitor Module | 3300 | 24 V DC | Analog | 160 × 80 × 40 | 0.70 |
Q1: What does this probe measure?
A: It measures shaft vibration and displacement without touching the rotating surface.
Q2: What does the “080” in the model indicate?
A: It denotes an 80 mm unthreaded length for the sensing tip.
Q3: Is this probe suitable for oil environments?
A: Yes, it is designed to operate in oil‑contaminated industrial environments.
Q4: Can it be used in high‑speed machinery?
A: Yes, it supports high frequency response suitable for fast rotating shafts.
Q5: Does it require calibration during installation?
A: Yes, proper gap setting is necessary for accurate measurement.
Q6: What materials can it detect?
A: It only detects conductive materials such as steel shafts.
Q7: How is the signal transmitted?
A: Through a coaxial cable to a proximitor interface module.
Q8: What is the typical installation gap?
A: Around 1–2 mm between probe tip and target surface.
Q9: Is it resistant to electromagnetic interference?
A: Yes, the design includes shielding to minimize interference.
Q10: What are common installation mistakes?
A: Incorrect gap, misalignment, and mismatched cable or sensor components.