Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen Bradley 1786-TPRT2T is a ControlNet IP67 TNC T-Tap assembly used to connect field devices to a ControlNet coaxial network in industrial environments. It belongs to the Allen-Bradley Bulletin 1786 ControlNet media product family and features a TNC-to-right-angle TNC connection arrangement.
The assembly consists of a sealed T-tap body and an integrated 1-meter drop cable with overmolded connectors. One end of the cable connects to the tap body through a TNC interface, while the device-side end uses a right-angle TNC connector. This configuration provides a compact connection arrangement for ControlNet nodes where cable routing and connector clearance need to be considered.
The 1786-TPRT2T is particularly suitable for applications requiring sealed network connections. When properly mated with compatible sealed connectors, the tap assembly provides IP67 protection against dust and water ingress.
Unlike a standard coaxial connector or cable extension, this product functions as a network tap. It provides a branch connection between the ControlNet trunk cable and an individual network node while maintaining the coaxial communication path.
Its right-angle connector arrangement distinguishes it from the straight-connector version 1786-TPST2T and makes connector orientation an important consideration during replacement and system planning.
| Parameter | Specification |
|---|---|
| Manufacturer | Allen-Bradley |
| Brand Owner | Rockwell Automation |
| Model | 1786-TPRT2T |
| Product Series | Bulletin 1786 ControlNet |
| Product Type | ControlNet Coax Tap |
| Network Type | ControlNet |
| Assembly Type | IP67 TNC T-Tap and Cable Assembly |
| Tap Connector | TNC |
| Cable Connector Arrangement | TNC to Right-Angle TNC |
| Cable Type | Coaxial Drop Cable |
| Cable Length | 1 meter |
| Connector Construction | Overmolded |
| Protection Rating | IP67 when properly mated with a sealed connector |
| Operating Temperature | -20 to +70°C |
| Storage Temperature | -40 to +85°C |
| Relative Humidity | 5–95%, non-condensing |
| Shipping Weight | 3 kg |
The 1786-TPRT2T operates as a passive coaxial network tap within a ControlNet communication system. Its function is to establish a branch connection between the main coaxial trunk and an individual network device.
The T-tap body connects to the ControlNet network media, while the integrated 1-meter drop cable links the tap to the node. The TNC connector at the tap end provides the connection to the sealed tap body, and the right-angle TNC connector at the opposite end connects to the ControlNet device.
ControlNet communication signals travel through the coaxial network infrastructure. The tap provides the required physical connection between the trunk cable and the node without functioning as an active repeater or signal-processing device.
The right-angle connector changes the physical orientation of the cable connection, helping technicians route the drop cable around adjacent equipment or within confined installation spaces.
When properly assembled with compatible sealed connectors, the connection maintains its IP67 environmental protection rating.
A simplified connection arrangement is:
ControlNet Coaxial Trunk → 1786-TPRT2T T-Tap → 1-Meter Drop Cable → ControlNet Node
The tap does not independently generate network signals, assign node addresses, or manage communication traffic. These functions are handled by the connected ControlNet devices and network infrastructure.
Within an Allen-Bradley ControlNet installation, the 1786-TPRT2T provides the physical media connection between the coaxial trunk and an individual network node.
ControlNet uses a coaxial trunk-and-tap topology. The trunk forms the main communication path, while individual taps connect controllers, communication modules, and other compatible devices to the network.
The 1786-TPRT2T is used where a sealed TNC connection and right-angle drop cable arrangement are required.
| System Component | Function |
|---|---|
| ControlNet Coaxial Trunk | Main communication transmission path |
| 1786-TPRT2T | Sealed TNC T-tap with right-angle TNC drop cable |
| 1786-RG6 | Standard ControlNet coaxial trunk cable |
| 1786-RG6F | High-flex ControlNet coaxial cable |
| 1756-CNB | ControlLogix ControlNet Bridge Module |
| 1756-CNBR | ControlLogix Redundant ControlNet Bridge Module |
| ControlNet Nodes | Devices communicating through the ControlNet network |
| ControlNet Terminators | Provide the required termination at both ends of the coaxial trunk |
The right-angle drop connection is particularly relevant when installing ControlNet communication hardware in cabinets where straight connectors may interfere with neighboring modules or cable routing.
The Allen Bradley 1786-TPRT2T is suitable for ControlNet installations that require sealed coaxial network connections and right-angle cable routing.
| Industrial Application | Typical Use |
|---|---|
| Manufacturing Automation | Connecting ControlNet nodes in production equipment |
| Automotive Production | Establishing sealed network connections in machinery |
| Material Handling | Connecting communication nodes along automated conveyor systems |
| Packaging Machinery | Providing right-angle coaxial connections inside control cabinets |
| Process Automation | Connecting ControlNet communication devices in industrial facilities |
| Industrial Robotics | Establishing coaxial network connections around robotic equipment |
| Water Treatment | Supporting protected communication connections in industrial installations |
| Heavy Industrial Equipment | Providing sealed network taps in demanding environments |
| Distributed Control Systems | Connecting remote ControlNet nodes to the main network |
| Factory Control Networks | Maintaining branch connections between the trunk and individual devices |
| Component | Function |
|---|---|
| Allen-Bradley 1786-TPRT2T | IP67 TNC T-Tap with Right-Angle TNC Drop Cable |
| Allen-Bradley 1786-TPST2T | IP67 TNC T-Tap with Straight TNC Drop Cable |
| Allen-Bradley 1786-TCT2BD1 | IP67 TNC T-Tap with Straight BNC Drop Connector |
| Allen-Bradley 1786-RG6 | Standard ControlNet Coaxial Cable |
| Allen-Bradley 1786-RG6F | High-Flex ControlNet Coaxial Cable |
| Allen-Bradley 1786-TNCLXT4 | ControlNet TNC 75 Ohm Terminator |
| Allen-Bradley 1756-CNB | ControlLogix ControlNet Bridge Module |
| Allen-Bradley 1756-CNBR | ControlLogix Redundant ControlNet Bridge Module |
| Model | Product Type | Application |
|---|---|---|
| Allen-Bradley 1786-TPST2T | ControlNet Coaxial IP67 TNC T-Tap | Straight TNC drop connection |
| Allen-Bradley 1786-TCT2BD1 | ControlNet Media IP67 TNC Tap | Straight BNC drop connection |
| Allen-Bradley 1786-TPR | ControlNet Right-Angle T-Tap | Standard coaxial network branch connection |
| Allen-Bradley 1786-TPS | ControlNet Straight T-Tap | Standard straight coaxial network connection |
| Allen-Bradley 1786-TPYR | ControlNet Right-Angle Y-Tap | Alternative coaxial network branching arrangement |
| Allen-Bradley 1786-TPYS | ControlNet Straight Y-Tap | Straight Y-type network branching arrangement |
Both models are ControlNet IP67 TNC T-tap and cable assemblies with a 1-meter drop cable. The main difference is the node-side connector orientation. The 1786-TPRT2T uses a right-angle TNC connector, while the 1786-TPST2T uses a straight TNC connector.
Yes. The assembly includes the T-tap body and an integrated 1-meter coaxial drop cable with overmolded connectors. The cable has a TNC connection at the tap body and a right-angle TNC connection at the ControlNet node end.
The assembly is rated IP67 when fully mated with a compatible sealed connector. The complete installation must also maintain appropriate sealing at all mating interfaces to achieve the specified environmental protection.
Not necessarily. Although both products use a right-angle connection arrangement, the 1786-TPRT2T is an IP67 TNC tap assembly, whereas the 1786-TPR is a standard ControlNet right-angle T-tap. Connector type, sealing requirements, and network installation configuration must be checked before selecting a replacement.