The 330130-045-00 is a 3300 XL series proximity transducer extension cable used in rotating machinery monitoring systems.
It is designed to connect a proximity probe to a proximitor (signal conditioning module), ensuring stable transmission of eddy-current signals used for vibration, shaft displacement, and position monitoring.
Model interpretation:
This model is widely used in industrial machinery condition monitoring where standard protection and reliable signal transmission are required.
System structure:
This system enables non-contact, high-precision measurement of rotating equipment condition.
The 330130-045-00 extension cable is engineered to:
It is built with a triaxial shielded structure to reduce electromagnetic interference and ensure measurement accuracy in harsh industrial environments.
The design follows standard 3300 XL system architecture, ensuring compatibility and interchangeability with probes and monitoring modules.
| Parameter | Specification |
|---|---|
| Model | 330130-045-00 |
| Series | 3300 XL |
| Product Type | Extension Cable |
| Cable Length | 4.5 m |
| Cable Structure | 75 Ω triaxial cable |
| Connector Type | Coaxial locking connector |
| Cable Design | Standard industrial shielded cable |
| Certification | Standard industrial configuration |
| Impedance | 75 Ω |
| Signal Type | Eddy-current vibration/displacement signal |
| Operating Temperature | -40°C to +85°C (typical industrial range from reference data) |
| EMI Shielding | Triaxial shielding |
| Outer Diameter | ~5–7 mm |
| Bend Radius | ≥25–50 mm |
| Dimensions | 26.3 × 5.8 × 2.8 cm |
| Weight | 0.45–2.0 kg (varies by packaging/vendor configuration) |
The 330130-045-00 is widely used in:
It is suitable for standard industrial environments where reliable signal transmission is required without hazardous-area certification needs.
Ensures accurate eddy-current measurement over medium-distance cable runs.
Triaxial shielding reduces electrical noise interference.
Compatible with standard 3300 XL probes and proximitor modules.
Designed for long-term operation in vibration-prone environments.
4.5 m length supports flexible mounting layouts.
No calibration needed when used in matched system configuration.
| Model | Description | Key Difference |
|---|---|---|
| 330130-040-00 | 4.0 m standard cable | Shorter length |
| 330130-040-10-00 | FluidLoc cable | Improved sealing |
| 330130-040-11-00 | Armored FluidLoc | Higher mechanical protection |
| 330130-045-05-00 | Certified version | Hazardous area compliance |
| 330130-080-00-00 | 8.0 m cable | Extended distance |
| Model | Description | Key Parameters |
|---|---|---|
| 330101-00-08-10-02-00 | Proximity probe | High-precision vibration sensing |
| 330180-51-00 | Proximitor sensor module | Signal conditioning unit |
| 330103-00-06-10-02-00 | Standard probe | General turbine monitoring |
| 330105-02-12-10-02-05 | High-temperature probe | Thermal resistance capability |
| 330500-00-20 | Velocity sensor | Vibration monitoring |
| Parameter | 330130-045-00 | 330130-040-00 | 330130-040-10-00 | 330130-040-11-00 | 330130-080-00 |
|---|---|---|---|---|---|
| Cable Length | 4.5 m | 4.0 m | 4.0 m | 4.0 m | 8.0 m |
| Cable Type | Standard shielded | Standard shielded | FluidLoc | Armored FluidLoc | Standard shielded |
| Certification | None | None | None | None | None |
| EMI Shielding | High | High | High | High | High |
| Mechanical Protection | Medium | Medium | Medium | High | Medium |
| Impedance | 75 Ω | 75 Ω | 75 Ω | 75 Ω | 75 Ω |
| Temperature Range | -40~85°C | -40~85°C | -40~125°C | -40~100°C | -40~85°C |
| Dimensions | 26.3×5.8×2.8 cm | 26.3×5.8×2.8 cm | 26.3×5.8×2.8 cm | 26.3×5.8×2.8 cm | 32×6×3 cm |
| Weight (kg) | 0.45–2.0 | 0.4–1.0 | 0.15–0.45 | 0.45–1.1 | 0.6–1.5 |
A1: It connects the proximity probe to the monitoring system for vibration and displacement signal transmission.
A2: It indicates a cable length of 4.5 meters.
A3: It indicates a standard configuration without special protection or certification.
A4: It is used in turbines, compressors, pumps, and rotating machinery systems.
A5: It carries eddy-current vibration and displacement signals.
A6: Yes, it is designed for full system compatibility.
A7: No calibration is required when used in matched systems.
A8: Yes, it is designed for industrial environments with vibration and electrical noise.
A9: Power generation, oil & gas, petrochemical, and heavy industry.
A10: It is designed for long-term continuous industrial operation under normal installation conditions.