Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The 330130-040-11-05 is a 3300 XL series proximity transducer extension cable designed for rotating machinery monitoring systems.
It is used to connect a proximity probe to a proximitor (signal conditioning module), ensuring stable transmission of eddy-current signals used for vibration, shaft displacement, and position measurement.
Model interpretation:
This version is intended for critical industrial environments requiring explosion protection compliance and high sealing performance.
System structure includes:
This system provides non-contact high-accuracy monitoring of rotating equipment.
The 330130-040-11-05 extension cable is designed to:
Its Armored FluidLoc structure combines mechanical protection and fluid sealing, while the (05) certification ensures suitability for hazardous industrial environments such as explosion-risk zones.
| Parameter | Specification |
|---|---|
| Model | 330130-040-11-05 |
| Series | 3300 XL |
| Product Type | Extension Cable |
| Cable Length | 4.0 m |
| Cable Construction | 75 Ω triaxial armored FluidLoc cable |
| Connector Type | Locking coaxial connector |
| Cable Design | Armored + FluidLoc sealed structure |
| Certification | CSA / ATEX / IECEx (05) |
| Impedance | 75 Ω |
| Capacitance | ~69.9 pF/m |
| Signal Type | Eddy-current vibration/displacement signal |
| Operating Temperature | -40°C to +100°C (typical field range) |
| EMI Shielding | High-density industrial shielding |
| Bend Radius | ≥30–50 mm (installation dependent) |
| Outer Diameter | ~5–7 mm |
| Mechanical Protection | Armored + sealed jacket |
| Environmental Rating | Industrial / hazardous area compatible |
| Dimensions | 26.3 × 5.8 × 2.8 cm |
| Weight | 0.45 – 1.1 kg |
This model is widely used in:
It is especially suitable for hazardous area installations requiring certified protection and high reliability.
Supports CSA, ATEX, and IECEx installation requirements.
Combines mechanical strength with oil and fluid resistance.
Maintains accurate eddy-current signal integrity.
Triaxial shielding reduces electromagnetic interference.
Designed for continuous operation under vibration and harsh conditions.
Prevents connector loosening in high-vibration machinery.
| Model | Description | Key Difference |
|---|---|---|
| 330130-040-10-05 | FluidLoc sealed version | Non-armored |
| 330130-040-03-05 | Armored cable | Mechanical protection focus |
| 330130-040-02-05 | Standard cable | General industrial use |
| 330130-045-11-05 | 4.5 m armored FluidLoc | Longer distance |
| 330130-080-11-05 | 8.0 m armored FluidLoc | Extended reach |
| Model | Description | Key Parameters |
|---|---|---|
| 330101-00-08-10-02-00 | Proximity probe | High-precision vibration sensing |
| 330180-51-00 | Proximitor sensor | Signal conditioning unit |
| 330103-00-06-10-02-00 | Standard probe | General machinery monitoring |
| 330105-02-12-10-02-05 | High-temperature probe | Thermal resistance capability |
| 330500-00-20 | Velocity sensor | General vibration monitoring |
| Parameter | 330130-040-11-05 | 330130-040-11-00 | 330130-040-10-05 | 330130-040-03-05 | 330130-080-11-05 |
|---|---|---|---|---|---|
| Cable Length | 4.0 m | 4.0 m | 4.0 m | 4.0 m | 8.0 m |
| Cable Type | Armored FluidLoc | Armored FluidLoc | FluidLoc | Armored | Armored FluidLoc |
| Certification | Yes (05) | No | Yes | Yes | Yes |
| Hazardous Area Use | Yes | No | Yes | Yes | Yes |
| Oil Resistance | High | High | High | Medium | High |
| Mechanical Protection | High | High | Medium | High | High |
| Impedance | 75 Ω | 75 Ω | 75 Ω | 75 Ω | 75 Ω |
| Temperature Range | -40~100°C | -40~80°C | -40~125°C | -40~125°C | -40~100°C |
| EMI Shielding | High | High | High | High | High |
| Weight (kg) | 0.45–1.1 | 0.4–1.0 | 0.15–0.45 | 0.45–1.1 | 0.6–1.5 |
A1: It connects the proximity probe to the monitoring system for vibration and displacement signal transmission.
A2: It indicates a 4.0-meter cable length.
A3: It indicates an armored FluidLoc sealed cable design.
A4: It indicates hazardous area certification (CSA/ATEX/IECEx).
A5: It is used in turbine, compressor, pump, and industrial rotating machinery systems.
A6: It transmits eddy-current vibration and displacement signals.
A7: Yes, due to its certified configuration.
A8: No calibration is required when used with matched system components.
A9: Harsh industrial, oil-exposed, and hazardous environments.
A10: It is designed for long-term continuous industrial operation.