The Allen-Bradley 1336-SN-SP15A Inverter Snubber PCB is a protection-related component in compatible 575V 1336 adjustable frequency drives. Damage to this PCB or its associated circuit can contribute to abnormal inverter operation, repeated drive trips, visible component overheating, or power-stage failures. However, these symptoms do not automatically prove that the snubber board is defective. Accurate fault diagnosis requires checking the drive’s operating history, power circuit condition, wiring, connections, and compatibility of the installed board.
This guide provides a structured approach to identifying possible 1336-SN-SP15A problems, isolating related power circuit faults, and deciding when replacement or specialist repair is required.
Contents: 1336-SN-SP15A Fault Diagnosis and Repair
- Common Inverter Snubber PCB Fault Symptoms
- Visual Inspection and Damage Identification
- Electrical Safety and Power Circuit Diagnosis
- Overheating and Repeated Component Failure
- Drive Trips and Abnormal Inverter Operation
- Connector, Jumper, and Installation Faults
- Step-by-Step Troubleshooting Workflow
- Repair and Replacement Decisions
- Technical FAQs
- Troubleshooting Conclusion
1. Common Allen-Bradley 1336-SN-SP15A Inverter Snubber PCB Fault Symptoms
A snubber PCB problem may appear as a power circuit fault rather than a clearly identified component alarm. The drive may trip during acceleration, operation under load, or switching transitions. In some cases, visible damage is found during an internal inspection.
| Observed Symptom | Possible Related Cause | Recommended Inspection |
|---|---|---|
| Visible PCB burn marks | Electrical overstress, overheating, or component failure | Inspect the snubber board and surrounding power assembly |
| Repeated drive trips | Power circuit fault, motor/load issue, or another drive protection condition | Record the exact drive fault and operating conditions |
| Cracked or damaged components | Electrical or thermal stress | Inspect the PCB and associated power components |
| Discolored PCB area | Localized overheating or poor electrical connection | Check nearby connections and components |
| Loose jumper connection | Incorrect installation or mechanical disturbance | Compare connector positions with the drive schematic |
| Repeated snubber board failure | Underlying inverter or power circuit problem | Investigate the wider power stage before replacement |
| Drive fails after board replacement | Incorrect part, wiring, jumper, or mounting arrangement | Verify part compatibility and installation details |
2. 1336-SN-SP15A Visual Inspection and Damage Identification
Visual inspection is a useful first diagnostic step, but it must be performed only after the drive has been safely isolated and the DC bus has been verified as discharged. The snubber PCB is located within a high-energy power assembly and must not be inspected by touching internal components while the drive is energized.
Signs of PCB Damage
- Darkened or charred areas on the circuit board.
- Cracked electronic components.
- Discolored or damaged solder joints.
- Burned connector housings.
- Visible damage to conductive tracks.
- Evidence of contamination or corrosion.
Inspect the Surrounding Components
A damaged snubber PCB may be associated with another fault in the inverter power circuit. Inspect the nearby power assembly, heatsink area, bus connections, mounting hardware, and related wiring. If other components show signs of overheating or electrical damage, the root cause may extend beyond the snubber board.
Do Not Diagnose by Appearance Alone
A board that appears discolored may have experienced thermal stress, but appearance alone does not establish its electrical condition. Conversely, a PCB can have an electrical fault without obvious external damage. Use the drive-specific diagnostic procedure and approved test methods to confirm the suspected fault.
3. Allen-Bradley 1336-SN-SP15A Electrical Safety and Power Circuit Diagnosis
Electrical safety is essential when diagnosing the 1336-SN-SP15A. The DC bus capacitors in a 1336 drive can retain dangerous energy after the input supply has been disconnected. Internal inspection and electrical testing must not begin until the manufacturer’s isolation and voltage verification procedure has been completed.
Safe Isolation Procedure
- Stop the connected machine using the approved shutdown sequence.
- Disconnect all applicable power sources.
- Apply lockout/tagout controls.
- Wait for the discharge period specified in the drive manual.
- Measure the DC bus voltage at the manufacturer’s designated test points.
- Verify the absence of control voltage at the specified control circuit points.
- Confirm that the circuit is safe before accessing the snubber assembly.
Do not use a fixed waiting time as a substitute for voltage measurement. The actual safe-work procedure must follow the exact drive documentation and site electrical safety requirements.
Check the Power Circuit for Related Damage
After isolation has been verified, inspect the relevant inverter assembly and associated connections. Look for visible damage, loose mounting hardware, damaged insulation, and abnormal heat discoloration. Any electrical measurements on the power assembly must be performed using the test methods and limits specified for the drive.
Why the DC Bus Must Be Verified
A drive can remain electrically hazardous even when the display is blank and the incoming power has been disconnected. The DC bus is a high-energy circuit. Contact with charged components can result in severe injury or equipment damage.
4. 1336-SN-SP15A Overheating and Repeated Component Failure
Repeated overheating or damage to the inverter snubber PCB should be treated as a possible system-level power circuit problem. Installing another board without identifying the original cause may lead to another failure.
Possible Causes of Snubber PCB Overheating
- Electrical stress within the inverter power circuit.
- Abnormal switching-related transient conditions.
- Damaged or degraded associated power components.
- Incorrect or incompatible replacement PCB.
- Loose or incorrectly positioned electrical connections.
- Environmental conditions outside the drive’s specified limits.
- Contamination or restricted cooling around the power assembly.
Check the Drive Cooling Environment
Inspect the drive enclosure, ventilation paths, heatsink condition, and surrounding air temperature. Dust buildup and restricted airflow can increase thermal stress on power components. Confirm that the drive is installed and operated within the environmental limits specified for its model.
Investigate Repeated Failures
If the replacement snubber PCB fails again, stop repeated replacement attempts. Record the drive fault history and operating conditions, then have the complete inverter power circuit evaluated by a qualified drive service technician. A recurring failure may indicate an underlying issue that cannot be corrected by replacing the snubber board alone.
5. Allen-Bradley 1336-SN-SP15A Drive Trips and Abnormal Inverter Operation
A drive trip is a system-level indication, not proof that the inverter snubber PCB has failed. The 1336 drive may trip because of motor overload, ground fault, overcurrent, DC bus conditions, power supply problems, or other protection events. The exact displayed fault code and the operating conditions at the time of the trip are essential diagnostic information.
Record the Drive Fault Information
Before resetting the drive, record the displayed fault message, fault history where available, motor operating condition, speed reference, load level, and the time at which the fault occurred. This information helps determine whether the failure is related to the power stage or another part of the drive system.
Compare Fault Timing with Operating Conditions
- Fault during power-up: inspect the drive startup condition and power circuit.
- Fault during acceleration: investigate the drive, motor, and load conditions.
- Fault under high load: review current demand and mechanical load.
- Fault after maintenance: verify wiring, connector positions, and replacement part compatibility.
- Fault after extended operation: inspect thermal conditions and cooling performance.
Separate Snubber Problems from Other Drive Faults
Check the exact fault code against the applicable 1336 drive troubleshooting manual. Do not interpret every overcurrent or DC bus fault as a snubber PCB failure. The snubber board should be considered one possible area of investigation when the fault evidence points toward the inverter power assembly.
6. 1336-SN-SP15A Connector, Jumper, and Installation Faults
Incorrect installation can create problems that appear immediately after maintenance. Jumper connectors, board orientation, mounting hardware, and part compatibility should all be verified when a drive develops a fault after snubber PCB replacement.
Incorrect Jumper Position
Jumper connectors must be installed in the positions specified by the exact drive schematic. An incorrectly positioned jumper can change the intended circuit configuration. Compare every connection with the documented arrangement rather than relying on the position of a different 1336 drive revision.
Loose or Damaged Connectors
Inspect connector housings and contacts for cracks, deformation, contamination, or poor retention. A connector that appears attached may not be fully seated. Do not force damaged connectors into position.
Incorrect Replacement Part
The 1336 product family includes snubber PCBs designed for different voltage classes, frame sizes, and power ratings. The 1336-SN-SP15A is identified as a 575V inverter snubber PCB. Installing a different snubber board based only on physical resemblance can result in an incompatible power circuit configuration.
Mechanical Mounting Problems
Check the mounting plate, fasteners, insulating supports, and board alignment. Loose hardware or incorrect mounting can expose the PCB to vibration, movement, or unintended contact with nearby components.
7. Step-by-Step Troubleshooting Workflow for the 1336-SN-SP15A
The following workflow helps maintenance teams distinguish a confirmed snubber PCB problem from faults elsewhere in the 1336 drive.
Step 1: Document the Original Drive Condition
Record the complete drive catalog number, voltage rating, horsepower, frame, fault code, and operating conditions. Note whether the fault occurred before or after any recent maintenance work.
Step 2: Check the Part Compatibility
Compare the installed snubber board with the drive-specific spare-parts list. Verify the 1336-SN-SP15A catalog number, applicable power rating, board position, and required quantity. Do not proceed with a replacement if compatibility remains uncertain.
Step 3: Isolate the Drive Safely
Apply lockout/tagout, follow the manufacturer’s discharge procedure, and verify the DC bus and control voltage conditions at the designated test points. Do not begin internal inspection until the required safe condition has been confirmed.
Step 4: Inspect the Snubber PCB and Surrounding Assembly
Look for visible damage, overheating, contamination, loose connections, damaged fasteners, and abnormal conditions in nearby power components. Record all findings before removing the board.
Step 5: Verify the Connectors and Mounting
Check jumper locations, connector condition, board alignment, mounting plate, and fasteners against the applicable service documentation.
Step 6: Determine Whether Replacement Is Necessary
If the PCB is visibly damaged or a confirmed electrical fault has been identified, use an approved replacement process. If the board appears intact but the drive continues to trip, investigate other power circuit and drive system causes before ordering another board.
Step 7: Complete Controlled Verification
After the repair, inspect the assembly, restore the protective covers, and follow the drive startup procedure. Monitor the drive status and operating behavior under an approved test condition. Document the result and retain the fault information for future maintenance.
8. Allen-Bradley 1336-SN-SP15A Repair and Replacement Decisions
Deciding whether to repair or replace a 1336-SN-SP15A depends on the condition of the PCB, the availability of an approved repair process, and the overall condition of the drive power assembly.
When Replacement Is Appropriate
- The PCB has visible burn damage or cracked components.
- The board has confirmed electrical damage.
- Connectors or conductive tracks are damaged beyond approved field repair.
- The replacement part can be verified as compatible with the exact drive.
- The drive service procedure specifies replacement of the assembly.
When Further Drive-Level Diagnosis Is Required
- The snubber PCB has been replaced but the drive fault remains.
- The replacement board fails repeatedly.
- Nearby inverter components show overheating or damage.
- The drive reports faults unrelated to the snubber circuit.
- The original fault cannot be reproduced or explained by the board condition.
Lifecycle Considerations
Rockwell Automation lists the 1336-SN-SP15A as discontinued effective January 31, 2022. When sourcing replacement parts, verify the catalog number, condition, revision, and compatibility documentation. The availability of surplus or refurbished stock does not by itself establish that a particular unit is suitable for a given drive.
Maintenance Record Checklist
| Record Item | Information to Capture |
|---|---|
| Drive identity | Full catalog number, voltage, horsepower, and frame |
| Component identity | 1336-SN-SP15A and board revision |
| Fault information | Displayed fault code and operating conditions |
| Inspection results | PCB condition and surrounding power circuit findings |
| Repair details | Connections inspected and components replaced |
| Verification | Startup result and controlled operational test |
9. Technical FAQs About 1336-SN-SP15A Troubleshooting
What are the symptoms of a damaged 1336-SN-SP15A?
Possible signs include visible PCB damage, burn marks, overheating, damaged connectors, or drive faults associated with the inverter power circuit. These symptoms require further diagnosis because they can also be caused by other drive components.
Does an overcurrent fault always mean the snubber PCB is defective?
No. Overcurrent faults can have several causes, including motor problems, excessive load, incorrect drive settings, wiring faults, and power-stage damage. Check the exact fault code and troubleshooting instructions before identifying the snubber board as the cause.
Why does the replacement snubber PCB fail again?
Repeated failure may indicate an underlying problem in the inverter power circuit, incorrect replacement compatibility, wiring errors, or abnormal operating conditions. Investigate the complete power assembly rather than repeatedly replacing the same board.
Can the 1336-SN-SP15A be used in a 460V drive?
The 1336-SN-SP15A is identified as a 575V inverter snubber PCB. Do not use it in a 460V drive unless the manufacturer documentation confirms compatibility for that exact configuration.
How many snubber boards are used in the applicable drive?
The referenced spare-parts information specifies three inverter snubber PCBs per applicable drive. Confirm the quantity and positions using the exact drive’s parts list.
What should be inspected after a snubber PCB overheats?
Inspect the surrounding power assembly, connectors, mounting hardware, bus connections, and cooling conditions. Check for signs of electrical overstress or damage to associated power components.
Can the snubber PCB be tested while the drive is running?
Do not touch or perform unauthorized internal testing on an energized drive. Follow the manufacturer’s diagnostic procedure and use qualified personnel and appropriately rated equipment for any required electrical testing.
Why must the DC bus voltage be measured before repair?
DC bus capacitors can retain dangerous electrical energy after the input supply is disconnected. Measuring the designated test points confirms whether the circuit has reached the safe condition required for internal work.
Is the 1336-SN-SP15A discontinued?
Yes. Rockwell Automation lists the part as discontinued effective January 31, 2022. Verify any replacement or surplus stock against the exact drive requirements.
When should a specialist inspect the complete drive?
Specialist inspection is recommended when the snubber PCB fails repeatedly, other power components show damage, the drive continues to trip after replacement, or the fault cannot be isolated using the approved service procedure.
10. Troubleshooting Conclusion: Allen-Bradley 1336-SN-SP15A Inverter Snubber PCB
The Allen-Bradley 1336-SN-SP15A is a specialized inverter snubber PCB used in compatible 575V 1336 drive power assemblies. Fault diagnosis should begin with the exact drive fault information, part compatibility, and a careful inspection of the snubber board and surrounding power components.
A damaged snubber PCB may be the direct cause of a problem, but repeated drive trips or recurring board failures can indicate a wider inverter power circuit issue. Safe DC bus isolation, correct jumper verification, and drive-specific replacement procedures are essential throughout the repair process.
Since the 1336-SN-SP15A is discontinued, accurate part identification and documented compatibility checks are particularly important. A controlled startup and complete maintenance record help reduce repeat failures and support the continued operation of legacy Allen-Bradley 1336 drive systems.