• Honeywell 51305980-836 Ethernet Redundant Cable
  • Honeywell 51305980-836 Ethernet Redundant Cable
  • Honeywell 51305980-836 Ethernet Redundant Cable
  • Honeywell 51305980-836 Ethernet Redundant Cable
Product Overview The Honeywell 51305980-836 Ethernet Redundancy Cable is a dedicated industrial communication cable designed for redundant controller configurations in Honeywell Experion control systems……
Honeywell 51305980-836 Ethernet Redundant Cable
  • Honeywell
  • 51305980-836
  • Ethernet Redundant Cable
  • USA
  • 1 meter
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Honeywell 51305980-836 Ethernet Redundant Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell 51305980-836 Ethernet Redundant Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell 51305980-836 Ethernet Redundant Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell 51305980-836 Ethernet Redundant Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Honeywell 51305980-836 Ethernet Redundancy Cable is a dedicated industrial communication cable designed for redundant controller configurations in Honeywell Experion control systems. It provides the physical Ethernet connection between paired C300 Controller IOTAs, supporting communication connectivity within a redundant controller arrangement.

In a distributed control system (DCS), controller redundancy is used to improve system availability. A redundant configuration typically includes two controllers that work together so that a standby controller can take over control responsibilities if the active controller encounters a failure. The redundancy cable is part of the hardware connection required by the system architecture.

The 51305980-836 is a 1-meter shielded twisted-pair Category 5 (STP CAT5) Ethernet cable with orange connector boots. Its compact length is intended for short-distance connections between controller IOTAs installed close to one another in an industrial control cabinet.

This cable is particularly relevant to Honeywell C300 controller installations where the specified redundancy connection is required. It should not be confused with ordinary Ethernet patch cables or the separate FTE network cables used for other communication links within a Honeywell Experion system.

Correct cable identification is important when maintaining a redundant controller arrangement. The connector configuration, cable type, length, and part number should be checked before ordering a replacement.

Technical Specifications

Parameter Specification
Brand Honeywell
Model 51305980-836
Product Type Ethernet Redundancy Cable
Application C300 Controller Redundancy
Compatible System Honeywell Experion PKS / Series C and Series 8 architectures, subject to system configuration
Cable Category CAT5
Cable Construction Shielded Twisted Pair (STP)
Cable Length 1 meter (36 inches)
Connector Identification Orange boots
Network Type Ethernet redundancy connection
Typical Connection Between paired C300 Controller IOTAs
Shipping Weight Provided 3 kg

Note: The 3 kg value is the supplied shipping weight, not a verified cable-only net weight. Connector details and other electrical characteristics should be confirmed against the exact cable assembly before substitution.

Function and Working Principle

The Honeywell 51305980-836 provides a physical communication path between two controller assemblies configured for redundancy. It does not perform controller processing or switching itself. Instead, it supports the communication connection required by the redundant hardware arrangement.

1. Controller Redundancy Connection

A redundant C300 controller arrangement uses paired controller hardware to improve availability. The redundancy cable connects the corresponding IOTAs according to the Honeywell system design.

This connection supports the communication required between the paired controller assemblies. Its correct installation is therefore important to the intended redundant configuration.

2. Ethernet Data Transmission

The cable uses shielded twisted-pair CAT5 construction. Ethernet signals are transmitted through pairs of conductors, while the shielding helps reduce the influence of external electromagnetic interference.

The cable is intended for the specific connection defined by the Honeywell controller architecture. It should not be assumed that every standard CAT5 cable is an approved substitute, even if the connector appears similar.

3. Support for System Availability

Redundant controller arrangements are designed to reduce the risk of losing control capability following a controller-related fault. The 51305980-836 provides one of the physical connections used in the specified architecture.

The cable alone does not create redundancy. Properly configured controllers, compatible IOTAs, correct system software, power arrangements, and appropriate network connections are also necessary.

4. Shielding and Signal Integrity

Industrial control cabinets contain power supplies, switching devices, motor drives, and other equipment that can generate electromagnetic interference.

The STP cable construction provides shielding around the signal conductors. Correct cable routing and connector installation are still necessary to maintain reliable communication.

5. Compact Cabinet Interconnection

The 1-meter length is intended for relatively short connections between nearby controller IOTAs. Using the specified cable length can help keep cabinet wiring organized and reduce unnecessary cable slack.

The actual routing path should be checked before installation to avoid excessive tension, sharp bends, or mechanical strain on the connectors.

Role in Honeywell Experion Control Systems

The 51305980-836 is a supporting component in Honeywell controller infrastructure. It is used within a larger control architecture rather than functioning as an independent network device.

C300 Controller Communication

The Honeywell C300 controller is used in Experion control system installations to execute process-control strategies. In a redundant arrangement, paired controller hardware is installed according to the system configuration.

The 51305980-836 provides the designated Ethernet redundancy cable connection between the associated controller IOTAs.

IOTA Interconnection

An Input Output Termination Assembly (IOTA) provides the physical interface for controller-related connections. The redundancy cable connects the corresponding IOTAs in the paired arrangement.

The cable should be installed only in the designated ports and according to the applicable hardware documentation. Connecting it to an unrelated Ethernet port may not provide the intended function.

Distributed Control System Availability

Industrial processes often require continuous monitoring and control. A redundant controller architecture can help maintain control availability when a primary controller encounters a fault.

The cable contributes to the physical communication infrastructure required by this architecture. Its correct part number and installation are important when maintaining an existing system.

Control Cabinet Organization

The short cable length is suitable for nearby hardware connections inside a control cabinet. The orange connector boots also provide a visible identification feature that can help technicians distinguish this cable from other Ethernet connections.

Industrial Applications

1. Honeywell C300 Controller Redundancy

The primary application is connecting paired C300 Controller IOTAs in a redundant controller configuration. The cable supports the designated connection between the two controller assemblies.

It is particularly relevant to maintenance projects involving existing Honeywell Experion installations.

2. Experion PKS Distributed Control Systems

Experion PKS installations use distributed control hardware to manage industrial processes. The 51305980-836 can be used in supported C300 redundancy arrangements within these systems.

The exact hardware generation and system configuration should be verified before ordering.

3. Chemical Processing Facilities

Chemical plants often use distributed control systems to supervise process variables, equipment conditions, and operating sequences. Controller redundancy can be an important part of the overall availability strategy.

The cable supports the specified controller interconnection within compatible Honeywell installations.

4. Oil and Gas Facilities

Oil and gas facilities may use Honeywell Experion systems for process monitoring and control. In installations with redundant C300 controllers, the correct redundancy cable is necessary to maintain the intended hardware configuration.

5. Power and Utility Applications

Power generation and utility facilities may depend on DCS infrastructure for monitoring auxiliary systems and coordinating plant operations. The cable can support compatible redundant controller installations in these environments.

6. Industrial Process Automation

Other process industries using Honeywell C300 controllers may also require this cable for controller redundancy maintenance, hardware replacement, or cabinet refurbishment.

Installation and System Integration

Correct installation is essential because this cable forms part of a designated controller redundancy connection.

1. Verify the Part Number

Before installation, confirm that the cable is marked 51305980-836. Do not select a replacement solely by appearance or connector type.

Honeywell offers other cable lengths in the same general redundancy cable family. These include 51305980-848, 51305980-860, and 51305980-884. They should be selected according to the actual cabinet layout and system requirements.

2. Confirm the Cable Length

The 51305980-836 is a 1-meter cable. This length is commonly used when the paired controller IOTAs are installed close together.

Measure the actual routing path before installation. The cable should reach both connection points without excessive tension or an unnecessarily tight bend.

3. Identify the Correct Connection Points

Confirm the designated redundancy ports on the paired C300 Controller IOTAs using the applicable Honeywell hardware documentation.

Do not connect the cable to unrelated FTE network ports or other Ethernet interfaces merely because the connectors appear compatible.

4. Maintain Proper Cable Routing

Route the cable neatly within the cabinet and avoid sharp bends, crushing, or contact with moving components. Where practical, separate communication cables from high-current power conductors and sources of electrical interference.

Maintain the manufacturer’s recommended bend radius and cable-management requirements.

5. Inspect Connectors and Shielding

Before connecting the cable, inspect both ends for damaged connectors, loose boots, contamination, or visible cable damage.

The shielding and connector condition should be maintained to support reliable communication in the industrial environment.

6. Follow Approved Maintenance Procedures

Replacement of a redundancy cable may affect controller communication. Maintenance personnel should follow the applicable Honeywell procedures and the site’s approved change-management and operating requirements.

Do not assume the cable can be disconnected or replaced during live operation without affecting the redundant controller arrangement. Confirm the system’s permitted maintenance procedure before disturbing the connection.

7. Verify System Status

After installation, confirm that the controller pair reports the expected redundancy and communication status. Check for related diagnostic alarms and verify that the system has returned to its intended operating condition.

Record the replacement part number and maintenance activity for future reference.

Compatible System Components

The 51305980-836 is used as part of a Honeywell controller infrastructure. The following components and systems may be relevant to an installation.

Component or System Function Integration Considerations
Honeywell C300 Controller Executes process-control strategies Must be part of a supported redundant controller arrangement
C300 Controller IOTA Provides controller hardware connections Cable connects the designated paired IOTAs
Honeywell Experion PKS Distributed control system platform Verify hardware generation and system configuration
Honeywell Experion Series C Control hardware architecture Confirm the applicable controller redundancy arrangement
Honeywell Experion Series 8 Control hardware architecture Follow the relevant hardware planning documentation
FTE Network Cables Provide separate fault-tolerant Ethernet network connections Do not confuse FTE cables with the controller redundancy cable
Controller Power Supply Supplies electrical power to controller hardware Verify the system’s redundant power arrangement separately
Control Cabinet Houses controller and communication hardware Provide suitable cable routing and physical protection

The table identifies related system components. It does not mean that these components are included with the cable.

Alternative Models and Replacement Considerations

Honeywell provides different cable lengths for its C300 controller redundancy connections. Selection should be based on the required connection and cabinet layout.

Part Number Description Length
51305980-836 Ethernet Redundancy Cable, STP CAT5, orange boots 1 meter
51305980-848 Ethernet Redundancy Cable, STP CAT5, orange boots 1.2 meters
51305980-860 Ethernet Redundancy Cable, STP CAT5, orange boots 1.5 meters
51305980-884 Ethernet Redundancy Cable, STP CAT5, orange boots 2 meters

These models belong to the same general cable family, but their lengths are different. They should not be treated as interchangeable without checking the actual cabinet layout and installation requirements.

When sourcing a replacement, verify:

  • Complete part number.
  • Cable length.
  • STP CAT5 construction.
  • Orange connector boots.
  • Connector condition and compatibility.
  • Intended C300 controller redundancy application.
  • Packaging and shipping requirements.

A generic Ethernet patch cable should not be substituted without confirmation that it meets the applicable Honeywell system requirements.

Key Advantages

Dedicated Controller Redundancy Connection

The cable is designed for the specified connection between paired Honeywell C300 Controller IOTAs, supporting the physical communication infrastructure of a redundant controller arrangement.

Shielded CAT5 Construction

The STP CAT5 construction provides shielding intended to help reduce the effects of electromagnetic interference in industrial control cabinets.

Compact 1-Meter Length

The 1-meter length is suitable for short-distance connections between closely installed controller assemblies, helping maintain an organized cabinet layout.

Visible Orange Connector Boots

The orange boots provide a recognizable identification feature that can help technicians distinguish the redundancy cable from other cabinet Ethernet connections.

Compatibility with Existing Honeywell Installations

The exact part number is useful for maintenance and replacement work involving compatible Honeywell Experion C300 controller systems.

Supports Maintenance of Redundant Hardware

Correct replacement of the designated cable helps maintain the physical connections required by the existing controller redundancy design.

Technical FAQs

1. What is the Honeywell 51305980-836?

The Honeywell 51305980-836 is a 1-meter STP CAT5 Ethernet redundancy cable designed for connecting paired C300 Controller IOTAs in compatible Honeywell Experion systems.

2. What is the cable length?

The specified cable length is 1 meter, equivalent to approximately 36 inches.

3. What is the main function of this cable?

Its main function is to provide the designated Ethernet redundancy connection between paired C300 Controller IOTAs.

4. What type of cable construction does it use?

It is identified as a shielded twisted-pair Category 5 Ethernet cable. The shielding helps reduce the influence of electromagnetic interference.

5. Why does the cable have orange connector boots?

The orange boots provide a visible identification feature for the C300 controller redundancy cable. They help distinguish it from other Ethernet cables used in the control cabinet.

6. Can a standard Ethernet cable replace the 51305980-836?

A standard Ethernet cable should not be assumed to be an approved replacement. The cable construction, connector arrangement, length, and Honeywell system requirements should be verified before substitution.

7. What is the difference between 51305980-836 and 51305980-848?

The main listed difference is cable length. The 51305980-836 is 1 meter long, while the 51305980-848 is 1.2 meters long. Select the correct length according to the installation layout.

8. Is this cable used for FTE network connections?

It is primarily identified as a C300 controller redundancy cable. Honeywell documentation lists separate FTEA and FTEB Ethernet cables for other network connections within the control cabinet.

9. Can the cable be replaced while the controller is operating?

Do not assume that it can be replaced during live operation. Disconnecting a redundancy connection may affect system status or availability. Follow the applicable Honeywell maintenance procedures and site operating requirements.

10. What does the 3 kg weight represent?

The 3 kg value supplied for this product is the shipping weight. It should not be interpreted as the verified net weight of the cable itself. Actual shipping weight may include packaging and other handling materials.

Procurement and Maintenance Recommendations

When purchasing the Honeywell 51305980-836, confirm the complete part number and the required 1-meter cable length. The connector boots, STP CAT5 construction, and intended C300 controller redundancy application should also be checked.

For critical DCS installations, verify that the replacement cable matches the existing system documentation. Do not select a generic Ethernet cable based only on connector appearance or nominal cable category.

For inventory management, distinguish net product weight from shipping weight. The supplied 3 kg figure should be retained as the shipping weight unless a verified net-weight specification is available.

During maintenance, inspect cable jackets, connectors, shielding, and routing. Avoid excessive bending, pulling, or crushing. Keep the cable away from sources of strong electrical interference where practical, and follow the cabinet wiring requirements.

After replacement, verify the controller pair’s communication and redundancy status. Document the cable part number and maintenance work so that future troubleshooting can identify the installed configuration accurately.

Conclusion

The Honeywell 51305980-836 Ethernet Redundancy Cable is a 1-meter STP CAT5 communication cable designed for the redundancy connection between paired C300 Controller IOTAs in compatible Honeywell Experion control systems.

Its orange connector boots and dedicated part number help identify it within the controller cabinet. Correct cable selection, installation, and maintenance are important for preserving the intended controller configuration.

For replacement and procurement projects, verify the complete model number, cable length, connector condition, and system compatibility. The supplied 3 kg value should be treated as shipping weight rather than cable net weight.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501