• GE 8920-PS-DC Power Supply
  • GE 8920-PS-DC Power Supply
  • GE 8920-PS-DC Power Supply
  • GE 8920-PS-DC Power Supply
Product Overview The GE 8920-PS-DC Power Supply is an industrial DC power supply module designed for intrinsically safe (IS) instrumentation and I/O systems. The product is associated with the MTL 8900-……
GE 8920-PS-DC Power Supply
  • GE
  • 8920-PS-DC
  • Power Supply
  • USA
  • 160 x 84 x 110 mm
  • 1.29 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

GE 8920-PS-DC Power Supply

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE 8920-PS-DC Power Supply

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE 8920-PS-DC Power Supply

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE 8920-PS-DC Power Supply

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE 8920-PS-DC Power Supply is an industrial DC power supply module designed for intrinsically safe (IS) instrumentation and I/O systems. The product is associated with the MTL 8900-series power supply architecture and is commonly listed in the industrial automation spare-parts market under GE and GE Fanuc product references.

Unlike a general-purpose 24 V DC power supply, the 8920-PS-DC is designed to provide a dedicated power source for compatible intrinsically safe modules. It accepts a nominal 24 V DC input, with an operating input range of 18.5–36 V DC, and provides a 12 V DC output with a capacity of up to 5 A.

The module is intended for use with compatible MTL system carriers, including the 8724-CA-PS power supply carrier. Within an appropriate installation, it supplies power to the internal power rails used by intrinsically safe I/O modules. Its galvanically isolated and voltage-clamped output design supports the electrical requirements of the associated instrumentation architecture.

One important feature of the 8920-PS-DC is its support for load sharing. Multiple compatible power supply modules can operate in a redundant arrangement, allowing the load to be shared rather than depending on a single supply. This can improve power availability in installations where continuous operation is important.

The module is suitable for industrial instrumentation systems in process plants and other environments where intrinsically safe interfaces are required. Correct carrier compatibility, system configuration, hazardous-area requirements, and power-supply ratings must be checked before installation.

Technical Specifications

Parameter Specification
Brand / Market Identification GE / GE Fanuc
Original Product Association MTL Instruments
Model 8920-PS-DC
Product Type IS Module DC Power Supply
Product Series 8900 Series
Nominal Input Voltage 24 V DC
Input Voltage Range 18.5–36 V DC
Output Voltage 12 V DC ±5%
Output Current Capacity 5 A
Output Characteristics Galvanically isolated and voltage-clamped
Voltage Clamp Reference 18 V nominal clamping level
Redundancy Support Load-sharing operation
Compatible Carrier 8724-CA-PS
Input Connection Duplicated two-part screw terminals
Maximum Cable Size 2.5 mm²
Efficiency at 18.5 V Input Approximately 76% at 4.1 A
Efficiency at 24 V Input Approximately 78% at 3.3 A
Efficiency at 36 V Input Approximately 76.5% at 2.1 A
Protection Rating IP20, subject to installation conditions
Operating Temperature Dependent on load and mounting orientation; up to +70°C at reduced load
Storage Temperature -40°C to +85°C
Relative Humidity 5–95% RH, non-condensing
Dimensions 160 × 84 × 110 mm
Weight 1.29 kg
Typical Application Power supply for compatible intrinsically safe I/O modules

The 12 V DC output and 18 V clamping specification describe different aspects of the module’s output design. Confirm the applicable system documentation when evaluating field-side voltage and intrinsic-safety parameters.

Function and Working Principle

The GE 8920-PS-DC converts an external DC input into a controlled supply for compatible intrinsically safe instrumentation modules. It is designed to work as part of a dedicated power distribution architecture rather than as an independent general-purpose power source.

1. DC Input Conversion

The module accepts a nominal 24 V DC supply within an operating range of 18.5–36 V DC. Its internal power-conversion circuitry regulates the incoming voltage to provide the required output for the connected system.

This input range gives the installation some tolerance for variations in the DC supply. However, the incoming voltage must remain within the specified operating limits to maintain reliable performance.

2. Regulated Output Supply

The 8920-PS-DC provides a nominal 12 V DC output with a rated capacity of 5 A. This supply supports the power requirements of compatible intrinsically safe modules connected through the appropriate carrier arrangement.

The output is galvanically isolated and voltage-clamped. These characteristics are important in instrumentation systems where the electrical relationship between internal power distribution and field-side circuits must be controlled.

3. Galvanic Isolation

Galvanic isolation separates the input and output circuits electrically while allowing power to be transferred through the power-conversion stage.

In industrial instrumentation installations, isolation can help prevent unwanted electrical interactions between different parts of the system. It is particularly relevant where intrinsically safe circuits and conventional control-system power distribution must be kept within their specified electrical boundaries.

The isolation rating and system grounding arrangement must be evaluated using the applicable manufacturer documentation.

4. Voltage Clamping

The module incorporates voltage-clamping characteristics intended for its associated intrinsically safe power architecture.

Voltage limitation is an important part of intrinsic-safety engineering because the electrical energy available to field circuits must remain within defined limits. The power supply must be used with the compatible carriers and I/O modules for which the system was designed.

The 8920-PS-DC should not be treated as a standalone replacement for certified intrinsic-safety barriers or isolators.

5. Load-Sharing Redundancy

The module supports load-sharing operation. In a suitable redundant configuration, compatible power supplies can share the system load.

This arrangement can improve power-system availability by reducing dependence on a single supply module. It also provides a practical basis for designing redundant power distribution in installations where an interruption to instrumentation power could affect plant operation.

Redundant operation requires compatible hardware, correct carrier connections, suitable input supplies, and a properly engineered system configuration.

Role in Industrial Control Systems

The 8920-PS-DC serves as a dedicated power source within an industrial instrumentation architecture. Its primary role is to provide controlled electrical power to compatible intrinsically safe I/O modules.

Powering Intrinsically Safe I/O Modules

Intrinsically safe I/O systems are used to connect control equipment with field instruments installed in potentially hazardous locations.

The 8920-PS-DC supplies power to the appropriate internal system rails through its compatible carrier. This allows the connected I/O architecture to operate within its intended electrical design.

Supporting Remote Instrumentation

Process facilities often distribute instruments across large areas. Remote I/O systems help collect signals from field devices and make them available to controllers and supervisory systems.

The power supply supports the instrumentation interface hardware that forms part of this arrangement. Its role is especially important where the system uses intrinsically safe modules for field connections.

Supporting Redundant Power Architecture

For installations requiring higher power availability, the load-sharing feature can be used as part of a redundant supply arrangement.

A properly engineered redundant configuration can help maintain power availability if one supply requires maintenance or experiences a fault. The actual system response depends on the redundancy design, connected load, and associated monitoring functions.

Integration with Control and Safety Systems

The power supply does not perform PLC logic, process control, or safety-program execution. Instead, it provides the electrical power needed by compatible instrumentation modules.

Those modules connect field signals to the wider automation architecture, where controllers and supervisory systems perform monitoring, control, alarm handling, and other application functions.

Industrial Applications

The GE 8920-PS-DC is relevant to instrumentation systems that require dedicated power for compatible intrinsically safe modules.

1. Oil and Gas Facilities

Oil and gas facilities often contain classified hazardous areas where intrinsically safe instrumentation is required.

The 8920-PS-DC can support compatible I/O modules used to interface with field instruments in these installations. Its load-sharing capability may also be useful in power architectures designed for continuous instrumentation availability.

2. Chemical Processing Plants

Chemical production facilities use pressure, temperature, flow, and level instruments to monitor process conditions.

Where the instrumentation architecture includes compatible intrinsically safe I/O modules, the power supply can provide the required internal module power through its designated carrier.

3. Petrochemical Installations

Petrochemical plants frequently use distributed instrumentation and control systems. The 8920-PS-DC can form part of the power arrangement supporting intrinsically safe field interfaces.

Its use must follow the system’s hazardous-area design and applicable installation requirements.

4. Process Automation Systems

Process automation systems depend on stable power for controllers, I/O modules, communication equipment, and field interfaces.

The 8920-PS-DC is intended for a specific part of this architecture: the power supply requirements of compatible IS modules. It should not be substituted for a general system power supply unless the system documentation explicitly permits that use.

5. Hazardous-Area Instrumentation

Applications involving flammable gases, vapors, or combustible environments may require intrinsically safe instrumentation circuits.

The 8920-PS-DC supports the associated MTL power architecture. The complete installation must still meet the relevant hazardous-area classification, certification, wiring, and segregation requirements.

Installation and System Integration

Correct installation is essential for maintaining the intended power-supply performance and intrinsic-safety design.

1. Verify the Input DC Supply

Before installation, confirm that the incoming supply is compatible with the module’s 18.5–36 V DC input range.

A nominal 24 V DC supply is commonly used. Check the available current capacity, wiring voltage drop, polarity, and protection arrangements before connecting the module.

2. Confirm Carrier Compatibility

The 8920-PS-DC is designed for carrier mounting, with the 8724-CA-PS identified as its associated power supply carrier.

Verify the exact carrier type and system arrangement before installation. Mechanical compatibility alone does not establish electrical or functional compatibility.

3. Connect the Input Terminals Correctly

The module uses duplicated two-part screw-terminal input connections. The maximum specified cable size is 2.5 mm².

Use conductors appropriate for the supply current and installation environment. Ensure that connections are secure and that cable routing follows the manufacturer’s recommendations.

4. Maintain Intrinsic-Safety Segregation

Intrinsic-safety installations require careful separation between IS and non-IS circuits.

Maintain the required segregation, grounding, shielding, and wiring practices specified by the system documentation and applicable standards. Do not modify the internal power distribution or field wiring arrangement without evaluating its effect on the intrinsic-safety design.

5. Configure Redundant Supplies Correctly

If load-sharing redundancy is required, use compatible modules and the appropriate carrier arrangement.

Verify that the input supplies, wiring, and connected loads are suitable for the intended configuration. Confirm that the system’s monitoring and fault-handling arrangements can identify power-supply problems.

6. Check Environmental Conditions

The published module information specifies IP20 protection under the stated installation conditions. This rating does not provide protection against water ingress or unrestricted exposure to dust.

Install the module in a suitable enclosure and maintain the required temperature, humidity, and ventilation conditions. Observe the temperature derating associated with mounting orientation and load.

7. Commission the Power Supply

After installation, inspect all connections and verify the input voltage before applying power.

Measure the output according to the applicable commissioning procedure. Confirm that the connected modules operate normally and that any redundant power supply arrangement shares the load as intended.

Record the installation details and relevant test results for future maintenance.

Compatible System Components

The 8920-PS-DC is intended to operate within a compatible MTL intrinsically safe power and I/O architecture.

Component Function Integration Considerations
8724-CA-PS Power Supply Carrier Provides the mounting and electrical interface for the power supply Confirm the correct carrier model and system configuration
Compatible IS I/O Modules Interface with intrinsically safe field instrumentation Check module power requirements and system compatibility
24 V DC Power Source Supplies the module input Maintain the specified 18.5–36 V DC input range
Redundant Power Supply Module Shares the power load in a redundant arrangement Use compatible hardware and approved carrier connections
MTL8000 Carrier Units Provide the system backbone for associated I/O modules Verify the complete system architecture
Field Instruments Provide measurement or control signals Confirm intrinsic-safety parameters and field wiring requirements
Grounding and Shielding Components Support electrical reference and interference management Follow the installation documentation
Industrial Enclosure Protects the installed equipment Maintain suitable environmental conditions and circuit segregation

The components listed above describe the associated system architecture. They are not necessarily included with an individual 8920-PS-DC power supply module.

Alternative Models and Replacement Considerations

The 8920-PS-DC is a specialized power supply. Replacement selection must consider its electrical characteristics and its role in the associated intrinsically safe system.

Alternative or Related Component Replacement Considerations
Another 8920-PS-DC module Check the complete part number, revision, condition, and certification markings
Compatible 8724-CA-PS carrier Required for the specified carrier-mounting arrangement; it is not a power supply replacement
Compatible MTL IS power supply Must match the system’s voltage, output, isolation, carrier, and intrinsic-safety requirements
Compatible redundant power supply arrangement Requires approved load-sharing support and matching system hardware
General-purpose 24 V DC power supply Not a direct replacement because it may not provide the required output, isolation, voltage limitation, or intrinsic-safety characteristics

Before selecting a replacement, verify:

  • Input voltage range and polarity.
  • Output voltage and current capacity.
  • Galvanic isolation characteristics.
  • Voltage-clamping requirements.
  • Load-sharing and redundancy support.
  • Carrier mounting compatibility.
  • Intrinsic-safety certification and system approvals.
  • Terminal arrangement and wiring requirements.
  • Environmental and temperature ratings.
  • Product revision and condition.

A general-purpose power supply with a similar input voltage cannot be assumed to replace the 8920-PS-DC. The output design and intrinsic-safety requirements are central to its function.

Key Advantages

Dedicated IS Module Power

The module is designed specifically for powering compatible intrinsically safe I/O modules rather than serving as a general-purpose DC supply.

Wide DC Input Range

Its 18.5–36 V DC input range supports installations using a nominal 24 V DC supply and allows for a defined range of input variation.

Galvanic Isolation

The isolated output design supports the electrical separation required by the associated instrumentation architecture.

Voltage-Clamped Output

Voltage-clamping characteristics help maintain the intended electrical limits within the compatible IS power system.

Load-Sharing Support

The module supports redundant load-sharing arrangements when installed with compatible system components.

Industrial Environmental Capability

The published specifications include defined operating temperature, humidity, vibration, and shock conditions for industrial installations.

Carrier-Based Integration

The 8724-CA-PS carrier arrangement provides a defined mounting and electrical interface for integration into the associated system.

Technical FAQs

1. What is the GE 8920-PS-DC?

The GE 8920-PS-DC is an industrial DC power supply module associated with the MTL 8900-series intrinsically safe power architecture. It supplies power to compatible IS I/O modules.

2. Is the 8920-PS-DC a standard 24 V DC power supply?

No. It accepts a nominal 24 V DC input but provides a dedicated 12 V DC output for compatible intrinsically safe modules. Its isolation and voltage-clamping characteristics are part of its intended system function.

3. What is the input voltage range?

The specified input range is 18.5–36 V DC, with 24 V DC as the nominal input.

4. What is the output rating?

The module provides a nominal 12 V DC output with a capacity of up to 5 A. Refer to the applicable system documentation for load and temperature limitations.

5. Does the module support redundant operation?

Yes. It supports load-sharing operation, allowing compatible power supply modules to share the load in an appropriately designed redundant configuration.

6. Which carrier is used with the 8920-PS-DC?

The associated carrier is the MTL 8724-CA-PS. Confirm the carrier revision and system arrangement before installation.

7. Can the 8920-PS-DC directly power ordinary 24 V field instruments?

It should not be treated as a general-purpose field-instrument supply. It is designed for the associated intrinsically safe module power architecture. Check the field device and I/O module requirements before making any connection.

8. Is the 8920-PS-DC suitable for hazardous-area systems?

It is designed for use within an intrinsically safe instrumentation architecture. The complete installation must comply with the relevant hazardous-area classification, certification, and wiring requirements. The module alone does not make an installation intrinsically safe.

9. What should be checked before purchasing a replacement?

Verify the full model number, revision, physical condition, terminal condition, output specifications, carrier compatibility, and certification markings. For used equipment, request suitable functional test information.

10. What is the difference between unit weight and shipping weight?

The specified module weight is approximately 1.29 kg. Packaging and additional carrier components may increase the total shipping weight. Confirm the actual shipment configuration when arranging transportation.

Procurement and Maintenance Recommendations

When sourcing the GE 8920-PS-DC, confirm that the product is the correct intrinsically safe module power supply and not a similarly described general-purpose DC supply.

Check the complete model number, manufacturer identification, revision, terminal arrangement, and physical condition. Since the product is associated with the MTL architecture, compatibility with the 8724-CA-PS carrier and the installed I/O system should be confirmed before ordering.

For used or surplus units, request clear photographs of the identification label, terminals, enclosure, and connector areas. Where the module is intended for a critical installation, obtain appropriate functional test information and verify the applicable certification documentation.

During maintenance, inspect the input connections, carrier interface, terminal condition, and enclosure for signs of overheating, corrosion, or mechanical damage. Verify input and output conditions according to the manufacturer’s procedures.

In redundant installations, check that the load-sharing arrangement operates as designed. Confirm that the connected modules remain within the power supply’s rated capacity and that the system can identify a failed or disconnected supply.

Maintain records of module revisions, carrier types, wiring changes, and test results. These details help reduce replacement errors and support long-term maintenance of industrial instrumentation systems.

Conclusion

The GE 8920-PS-DC Power Supply is a specialized industrial DC power module associated with the MTL intrinsically safe instrumentation architecture. It accepts a nominal 24 V DC input within an 18.5–36 V DC range and provides a 12 V DC output with a capacity of up to 5 A.

Its galvanically isolated, voltage-clamped output and load-sharing capability make it suitable for compatible IS module power arrangements. With a defined carrier-mounting configuration and industrial environmental specifications, it supports power distribution in instrumentation systems where intrinsic-safety requirements must be maintained.

For maintenance and replacement projects, the most important considerations are correct carrier compatibility, output characteristics, redundant operation, and certification requirements. The 8920-PS-DC should always be selected as part of the complete system design rather than treated as an interchangeable general-purpose power supply.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501