The GE IC086SLN050 Industrial Unmanaged Ethernet Switch is a compact industrial networking device designed to connect Ethernet-enabled equipment within automation and control systems. It belongs to the PACSystems Industrial Ethernet Switch family, associated with GE industrial automation products and now part of Emerson’s PACSystems portfolio.
The IC086SLN050 provides five 10/100Base-T(X) Ethernet ports for connecting devices such as programmable logic controllers, industrial computers, operator interfaces, remote I/O systems, and other Ethernet-based equipment. As an unmanaged switch, it is designed for straightforward network expansion without requiring users to configure VLANs, routing tables, or other managed network functions.
In industrial environments, reliable communication between control devices is essential. PLCs exchange data with supervisory systems, operator stations, and distributed equipment. An industrial Ethernet switch provides the physical network connections needed to support this communication architecture.
The IC086SLN050 uses store-and-forward switching technology. It receives an Ethernet frame, checks it, and then forwards it through the appropriate port. This approach supports organized data transmission between connected devices and is commonly used in industrial Ethernet networks.
The unit is designed for compact installation and has an IP30 enclosure rating. Its documented operating temperature range is -40°C to +70°C, making it suitable for properly designed industrial control cabinets and equipment enclosures. The switch also supports redundant input power and includes overload-current and reverse-polarity protection.
With five Ethernet ports, low typical power consumption, and a small physical footprint, the IC086SLN050 is intended for applications where a simple industrial network connection is required without the additional configuration functions of a managed switch.
| Parameter | Specification |
|---|---|
| Brand | GE |
| Product Family | PACSystems Industrial Ethernet Switches |
| Model | IC086SLN050 |
| Product Type | Industrial Unmanaged Ethernet Switch |
| Network Management | Unmanaged |
| Ethernet Ports | 5 × 10/100Base-T(X) |
| Fiber Ports | Not provided |
| Ethernet Standards | IEEE 802.3, IEEE 802.3u, IEEE 802.3x |
| Switching Method | Store-and-forward |
| MAC Address Table | 1,024 entries |
| Redundant Input Power | Supported |
| Typical Power Consumption | 3 W |
| Overload Current Protection | Supported |
| Reverse Polarity Protection | Supported |
| Enclosure Rating | IP30 |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Operating Humidity | 5% to 95%, non-condensing |
| Dimensions Provided | 95 × 26.1 × 70 mm |
| Weight Provided | 0.205 kg |
| Mounting | Industrial panel / DIN-rail installation, according to the mounting arrangement |
| Typical Application | Industrial Ethernet network connectivity |
Note: Confirm the power-input range, terminal arrangement, mounting hardware, and exact environmental requirements against the documentation supplied with the individual unit before installation.
The primary function of the IC086SLN050 is to connect multiple Ethernet devices and forward network traffic between them. It operates at the data-link layer of the Ethernet network and uses MAC addresses to determine where received frames should be sent.
The switch provides five copper Ethernet ports. Each port can connect to a compatible device using an appropriate Ethernet cable.
Typical connected equipment includes:
By connecting these devices through one switch, engineers can build a local communication segment without requiring a separate direct connection between every pair of devices.
The IC086SLN050 uses a store-and-forward switching method. When an Ethernet frame arrives, the switch receives the frame before forwarding it to the destination port.
This method allows the switch to check frame integrity before forwarding. It helps prevent corrupted frames from being passed through the network and supports predictable Ethernet switching behavior.
The switch uses its MAC address table to associate connected devices with the ports through which they are reachable. When a device sends traffic, the switch learns its source MAC address and uses this information to make forwarding decisions.
The documented MAC address table capacity is 1,024 entries. This allows the switch to maintain address information for connected network devices and support communication across the five available ports.
When a device communicates through the switch, its MAC address can be learned dynamically. This reduces unnecessary traffic on unrelated ports compared with simply repeating every received frame to all connected devices.
The MAC table capacity is a technical resource, not a guarantee of a particular network throughput. Actual performance also depends on traffic patterns, connected equipment, cable quality, and network design.
The switch supports IEEE 802.3x flow control. Flow control is intended to help manage traffic when a receiving device cannot accept incoming frames as quickly as they arrive.
In compatible full-duplex Ethernet environments, flow control can help reduce frame loss caused by temporary congestion. Its effectiveness depends on the network devices and their configuration.
The IC086SLN050 supports redundant input power. This allows the switch to be connected to a suitable redundant power arrangement so that a second power source can help maintain operation if the primary input becomes unavailable.
For industrial systems where network connectivity is important, redundant power can reduce the risk of a single supply interruption affecting the switch.
The actual wiring arrangement, input voltage limits, and power-source requirements must be checked against the product documentation. Redundant power does not replace the need for properly designed upstream power protection.
The switch includes overload-current protection and reverse-polarity protection. These functions help protect the device against certain electrical supply and wiring abnormalities.
They should not be treated as a substitute for correct wiring, suitable external protection, or compliance with the manufacturer’s installation instructions.
The IC086SLN050 can serve as a local Ethernet connection point in a machine-level or control-panel network. It provides a practical way to connect several devices that need to exchange information over Ethernet.
A programmable logic controller may communicate with an HMI, engineering computer, or other Ethernet-enabled equipment. The switch provides the physical network connections required for these devices to participate in the same Ethernet segment.
For example, a PLC can exchange production data with an operator station while an engineering workstation accesses the controller for programming or diagnostics, subject to the network architecture and access controls.
An HMI provides operators with information about machine conditions, alarms, and production status. When the HMI and PLC use Ethernet communication, the IC086SLN050 can connect them through a common industrial network.
The switch does not generate process information or execute control logic. Those functions remain with the PLC, HMI, and other connected automation devices.
Industrial computers may be used for data collection, visualization, maintenance, or production reporting. Connecting these computers through an industrial switch allows them to communicate with compatible control devices.
For installations involving sensitive control networks, engineers should plan network access carefully and separate control traffic from general office or business network traffic where appropriate.
Some automation systems contain several devices located within one machine or cabinet. A five-port switch can provide local connectivity for a compact group of Ethernet-enabled components.
The number of available ports should be considered during network design. If the installation requires additional devices, a larger switch or an additional network segment may be necessary.
The IC086SLN050 is suitable for industrial applications requiring simple Ethernet connectivity. Its compact design and five-port configuration make it relevant to local network installations where managed switching functions are not required.
PLC cabinets often contain controllers, HMIs, communication modules, and engineering access points. An unmanaged Ethernet switch can connect these devices within a local network.
The IC086SLN050 provides five ports for a small group of Ethernet-enabled devices. Its compact dimensions help reduce the space required for network equipment inside a control cabinet.
Automated manufacturing machines frequently use Ethernet to exchange information between controllers, operator interfaces, and monitoring devices.
A local switch can connect these components and support communication within the machine. This is useful in production equipment where network expansion is needed but advanced network management is unnecessary.
Packaging lines and material-handling systems may contain PLCs, barcode readers, industrial computers, and operator panels. Ethernet connectivity allows these devices to exchange status information and production data.
The IC086SLN050 can provide a local connection point for a limited number of compatible devices. Network traffic requirements and the need for deterministic communication should be considered during system design.
Water treatment and wastewater installations commonly use distributed control equipment, local operator stations, and monitoring systems.
A compact industrial switch can support local Ethernet connections within a control enclosure. Where the network serves critical process functions, engineers should evaluate redundancy, network segmentation, environmental conditions, and maintenance access.
Industrial Ethernet is used in utility installations and infrastructure monitoring systems to connect controllers and communication equipment.
The IC086SLN050’s documented industrial operating temperature range can be useful in appropriately designed enclosures exposed to varying ambient conditions. The enclosure itself must still provide the required environmental protection.
Industrial computers and monitoring devices may collect operational information from PLCs and other Ethernet-enabled equipment.
A local unmanaged switch can provide the network connections required for this type of installation. For larger data-collection architectures, network capacity, security, and traffic separation should be considered before expanding the system.
Correct installation is important for network stability, electrical safety, and long-term operation.
Before applying power, confirm the switch’s input voltage range and terminal configuration using the manufacturer’s documentation for the exact model.
The IC086SLN050 supports redundant input power, but the two power connections must be wired according to the specified arrangement. Do not assume that any two DC supplies can be connected without checking voltage limits, polarity, and grounding requirements.
Use a suitable industrial power source and provide appropriate upstream protection.
The supplied dimensions are 95 × 26.1 × 70 mm, and the listed weight is 0.205 kg.
Check the physical dimensions and mounting arrangement before designing the control panel. Leave enough space for Ethernet connectors, power wiring, ventilation, and maintenance access.
The IP30 enclosure rating provides protection against access by solid objects of the specified size but does not provide water protection. Install the switch inside an appropriate cabinet if the surrounding environment contains moisture, conductive dust, or other contaminants.
Use Ethernet cables suitable for the industrial environment and the required communication speed. Inspect cable condition, connector locking, and routing before connecting equipment.
Where cables run near motor drives, contactors, or other sources of electrical interference, follow appropriate cable separation and grounding practices.
The IC086SLN050 provides five 10/100Base-T(X) ports. It does not provide fiber-optic ports, so fiber connections require suitable additional equipment or a different switch configuration.
An unmanaged switch is generally straightforward to deploy. Connected devices can communicate over the same Ethernet segment when their IP settings and network configuration are compatible.
Before commissioning, document:
Avoid creating unintended Ethernet loops. An unmanaged switch does not provide the same network-management and loop-control capabilities as a managed switch.
After connecting the power supply and Ethernet cables, check the switch’s status indicators according to the product documentation.
Confirm that the expected link indicators are active and that connected devices can communicate. If a connection fails, inspect the cable, port, power supply, IP configuration, and connected device before replacing the switch.
A practical commissioning process should include checking the power supply, confirming Ethernet link status, and testing communication between the connected devices.
For a PLC and HMI installation, verify that the operator interface can access the intended controller and that normal process data is exchanged correctly.
Record the final network layout and device addressing information for future maintenance.
The IC086SLN050 is designed to connect compatible Ethernet devices. It does not replace the control functions of PLCs, HMIs, or industrial computers.
| Component | Function | Integration Considerations |
|---|---|---|
| PACSystems PLC | Executes automation logic | Verify Ethernet interface and network settings |
| Industrial HMI | Displays process information and operator controls | Confirm IP addressing and communication protocol |
| Industrial PC | Supports engineering, monitoring, and data collection | Plan network access and cybersecurity controls |
| Ethernet communication module | Provides network connectivity to controllers | Check supported Ethernet standards and connector type |
| Industrial Ethernet cable | Connects network devices | Select suitable cable category and environmental rating |
| 24 V DC power supply | Supplies power to the switch where compatible | Confirm the actual input range and wiring requirements |
| Redundant DC power source | Provides an alternative supply path | Follow the switch’s redundant-input wiring instructions |
| Control cabinet | Protects installed automation equipment | Provide suitable environmental protection and cable access |
| Network monitoring workstation | Supports diagnostics and maintenance | Account for the unmanaged nature of the switch |
The listed components are examples of equipment that may be used in an industrial network. They are not necessarily included with the IC086SLN050.
The PACSystems industrial Ethernet switch family includes different port counts and managed or unmanaged configurations. A replacement should be selected according to the network’s port requirements, communication standards, and management needs.
| Alternative Model | General Difference | Selection Considerations |
|---|---|---|
| IC086SLN080 | Unmanaged switch with 8 copper Ethernet ports | Suitable when more copper ports are required |
| IC086SLN240 | Unmanaged switch with 24 copper Ethernet ports | Intended for larger local Ethernet installations |
| IC086SLN042MM | Managed model with copper and multimode fiber connectivity | Consider where fiber connections and management functions are required |
| IC086SLN042SS | Managed model with copper and single-mode fiber connectivity | Consider for compatible single-mode fiber networks |
| IC086SLM042MM | Lite managed switch configuration with multimode fiber | Evaluate required management and fiber functions |
| IC086SLM042SS | Lite managed switch configuration with single-mode fiber | Evaluate fiber type, port requirements, and network design |
These models are related products, not guaranteed direct replacements. Before substitution, compare:
If the original installation uses the IC086SLN050 because of its simple unmanaged operation, replacing it with a managed switch may introduce additional configuration requirements. Conversely, a five-port switch may not provide enough capacity for an installation that has expanded since the original system was commissioned.
The five 10/100Base-T(X) ports allow several compatible industrial devices to share a local Ethernet network.
The switch is designed for installations that do not require advanced network configuration. This can simplify deployment in small machine networks and control cabinets.
The switching method receives and checks Ethernet frames before forwarding them, supporting standard Ethernet communication.
Redundant input power allows a suitable dual-supply arrangement to be used to improve power availability.
Overload-current and reverse-polarity protection help protect the device against certain electrical abnormalities.
The 95 × 26.1 × 70 mm dimensions and 0.205 kg listed weight make the unit suitable for installations where panel space is limited.
The documented operating range of -40°C to +70°C supports use in appropriately designed industrial environments.
The documented typical power consumption is 3 W, making the switch suitable for compact control installations with limited auxiliary power capacity.
The IC086SLN050 is an industrial unmanaged Ethernet switch from the PACSystems product family. It provides five 10/100Base-T(X) copper Ethernet ports for connecting industrial automation devices.
It has five 10/100Base-T(X) Ethernet ports. These ports can connect compatible PLCs, HMIs, industrial computers, and other Ethernet-enabled devices.
It is an unmanaged switch. It is designed for straightforward Ethernet connectivity without requiring users to configure advanced network-management functions.
It uses store-and-forward switching. The switch receives an Ethernet frame and checks it before forwarding it through the appropriate port.
Yes. The product documentation identifies redundant input power as a supported feature. The actual power-input range and wiring arrangement should be confirmed before installation.
The documented typical power consumption is 3 W. Actual power requirements should be checked against the product’s electrical specifications and connected installation.
The IC086SLN050 has an IP30 enclosure rating. It should be installed in a suitable cabinet where protection from water, conductive dust, or other environmental hazards is required.
The documented operating temperature range is -40°C to +70°C. The surrounding cabinet and installation conditions must also be suitable for the intended environment.
Yes. If both devices have compatible Ethernet interfaces and correctly configured network settings, they can be connected through the switch. The switch provides network connectivity but does not configure the PLC or HMI communication parameters.
A model such as the IC086SLN080 may be considered when additional copper Ethernet ports are required. Before replacement, verify power requirements, mounting, network characteristics, and the exact product configuration.
When purchasing the GE IC086SLN050, verify the complete model number and confirm that the unit is the five-port unmanaged configuration. Similar PACSystems switches may have different port counts, fiber interfaces, or network-management functions.
For new-old-stock or used equipment, request clear photographs of the product label, Ethernet ports, power terminals, and enclosure. Check for damaged connectors, cracked housing, corrosion, and signs of overheating. Where possible, request a functional test showing that the switch powers up and establishes Ethernet links with compatible devices.
Confirm whether power connectors or mounting accessories are included. The listed dimensions and weight describe the product information supplied for this article and should be checked against the actual shipment when preparing logistics documentation.
During routine maintenance, inspect the Ethernet cables, connectors, power wiring, grounding, and cabinet environment. Ensure that ventilation and installation clearances are maintained. If a connected device loses communication, check its power, cable, port link status, and IP configuration before assuming that the switch has failed.
Because the IC086SLN050 is unmanaged, it does not provide the same diagnostic visibility and configuration controls as a managed network switch. For systems requiring detailed traffic monitoring, VLAN segmentation, or advanced network redundancy, evaluate whether a managed industrial switch is more appropriate.
The GE IC086SLN050 Industrial Unmanaged Ethernet Switch is a compact five-port networking device designed for industrial automation applications. It provides 10/100Base-T(X) connectivity, store-and-forward switching, redundant input power support, overload-current protection, and reverse-polarity protection.
With a typical power consumption of 3 W, an IP30 enclosure rating, and a documented operating temperature range of -40°C to +70°C, it can support local Ethernet connections in properly designed industrial control cabinets.
For maintenance and replacement projects, the most important selection factors are port count, Ethernet speed, power-input arrangement, environmental requirements, and compatibility with the existing network architecture. Accurate model verification helps ensure that the replacement provides the connectivity required by the automation system.