• Siemens 6AG1315-2EH14-7AB0 Central Processing Unit
  • Siemens 6AG1315-2EH14-7AB0 Central Processing Unit
  • Siemens 6AG1315-2EH14-7AB0 Central Processing Unit
  • Siemens 6AG1315-2EH14-7AB0 Central Processing Unit
Product Overview The Siemens 6AG1315-2EH14-7AB0 Central Processing Unit is a SIPLUS S7-300 programmable logic controller CPU designed for industrial automation systems operating under extended environme……
Siemens 6AG1315-2EH14-7AB0 Central Processing Unit
  • Siemens
  • 6AG1315-2EH14-7AB0
  • Central Processing Unit
  • Germany
  • 40 × 125 × 130 mm
  • 0.398 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Siemens 6AG1315-2EH14-7AB0 Central Processing Unit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG1315-2EH14-7AB0 Central Processing Unit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG1315-2EH14-7AB0 Central Processing Unit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG1315-2EH14-7AB0 Central Processing Unit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG1315-2EH14-7AB0 Central Processing Unit is a SIPLUS S7-300 programmable logic controller CPU designed for industrial automation systems operating under extended environmental conditions. Based on the SIMATIC S7-300 CPU 315-2 PN/DP, this processor combines PLC program execution, industrial communication, and process coordination in a compact controller module.

As the central processing component of an S7-300 automation station, the CPU executes user programs, processes control instructions, manages data, and coordinates communication with distributed I/O devices and other automation equipment. It supports applications that require reliable sequencing, machine coordination, equipment monitoring, and communication between different levels of an industrial control system.

The 6AG1315-2EH14-7AB0 is distinguished by its conformal coating and extended operating temperature range of -25 to +70°C. These characteristics make it suitable for selected industrial installations where environmental conditions may exceed those normally encountered in standard control cabinets.

The processor provides 384 KB of integrated work memory and two communication interfaces. The first interface supports MPI/PROFIBUS DP communication at up to 12 Mbps, while the second provides Ethernet PROFINET connectivity through an integrated two-port switch. This combination allows the CPU to communicate with programming devices, operator interfaces, distributed control stations, and compatible industrial equipment.

A Siemens Micro Memory Card is required for load-memory storage. The CPU is programmed using STEP 7 V5.5 or higher, making it suitable for maintenance and engineering environments based on the corresponding SIMATIC S7-300 software platform.

For facilities maintaining existing S7-300 installations, the 6AG1315-2EH14-7AB0 provides a specific SIPLUS CPU configuration that should be identified by its complete order number. Similar-looking S7-300 CPUs may have different communication interfaces, memory capacities, environmental specifications, and firmware versions.

Technical Specifications

Parameter Specification
Brand Siemens
Product Family SIPLUS S7-300
Model 6AG1315-2EH14-7AB0
Product Type Central Processing Unit
CPU Designation CPU 315-2 PN/DP
Base Model 6ES7315-2EH14-0AB0
Integrated Work Memory 384 KB
Load Memory Siemens Micro Memory Card
Maximum MMC Capacity 8 MB
First Communication Interface MPI / PROFIBUS DP
First Interface Transmission Rate Up to 12 Mbps
Second Communication Interface Ethernet PROFINET
PROFINET Switch Integrated 2-port switch
Supply Voltage 24 V DC
Permissible Supply Range 20.4–28.8 V DC
Rated Current Consumption 750 mA
Typical No-Load Current Consumption 150 mA
Typical Inrush Current 4 A
Typical Power Dissipation 4.65 W
Operating Temperature -25 to +70°C
Protective Design Conformal coating
Programming Software STEP 7 V5.5 or higher
Dimensions Provided 40 × 125 × 130 mm
Weight Provided 0.398 kg
Application Industrial PLC control and automation

The listed dimensions and weight are the supplied product data. Confirm the hardware revision and actual shipping configuration when preparing procurement or logistics documentation.

Function and Working Principle

The Siemens 6AG1315-2EH14-7AB0 performs the central processing functions of an S7-300 PLC station. It receives process information, executes the configured control program, updates output commands, and exchanges data with other automation devices.

1. PLC Program Execution

The CPU executes the user program developed in the Siemens STEP 7 engineering environment. The program contains the logic required to control machines, production sequences, process equipment, and industrial operations.

During normal operation, the CPU processes input information, evaluates logic conditions, performs calculations, and updates the corresponding control outputs. This cycle allows the automation system to respond to changing machine and process conditions.

The 384 KB integrated work memory provides storage for program execution and associated working data. The available memory must be considered when designing larger control applications with extensive logic, data blocks, and communication functions.

2. Process Data Management

Industrial automation systems continuously exchange information between field devices, controllers, and operator interfaces.

The CPU manages process variables, internal data, control states, and communication information required by the user program. These data may include equipment operating conditions, production counters, alarm states, temperature measurements, and machine status information.

Organized data management helps engineers develop structured PLC applications and simplifies maintenance and troubleshooting.

3. MPI and PROFIBUS DP Communication

The first communication interface supports MPI and PROFIBUS DP at transmission rates of up to 12 Mbps.

MPI can be used for communication with compatible Siemens programming devices and automation components. PROFIBUS DP supports communication with distributed I/O stations and other compatible field devices.

In a distributed automation architecture, the CPU can exchange process data with remote equipment rather than requiring every signal to be connected directly to the central rack.

This arrangement can simplify wiring and support modular machine configurations.

4. PROFINET Communication

The second interface provides Ethernet PROFINET connectivity and incorporates a two-port switch.

PROFINET is widely used in industrial automation for communication between PLCs, distributed I/O stations, drives, and other compatible devices.

The integrated switch supports network connections through the CPU without requiring every connected device to have a separate direct connection to the main network infrastructure.

Network design should account for device compatibility, addressing, topology, cycle-time requirements, and the communication configuration established in the engineering project.

5. Micro Memory Card Storage

The 6AG1315-2EH14-7AB0 requires a Siemens Micro Memory Card for load-memory storage.

The card stores the user program and associated load data. It also provides a maintenance-free backup arrangement for program and data retention under the specified conditions.

The maximum supported MMC capacity is 8 MB. The selected card must be compatible with the CPU and the intended application.

When replacing a CPU, engineers should verify the memory-card type and project version before transferring the program or restoring the original configuration.

Role in Industrial Control Systems

The CPU 315-2 PN/DP serves as the central controller in a Siemens S7-300 automation station. It coordinates field-level devices, communication networks, and operator-control systems.

PLC-Based Machine Control

The CPU executes the logic responsible for machine sequencing, equipment interlocking, timing, counting, and process coordination.

For example, in a packaging machine, the controller can coordinate product detection, conveyor operation, positioning mechanisms, and packaging sequences.

The actual control behavior depends on the user program and connected hardware.

Distributed I/O Coordination

Through PROFIBUS DP and PROFINET, the CPU can communicate with compatible distributed I/O stations.

Remote input modules provide information from sensors and switches, while output modules control actuators, relays, and other field devices.

This architecture can reduce long point-to-point wiring runs and support distributed machine layouts.

Industrial Network Integration

The combination of MPI/PROFIBUS DP and Ethernet PROFINET allows the CPU to participate in different communication levels of an industrial automation system.

It can exchange data with compatible field devices, engineering tools, and supervisory equipment.

Network configuration should be planned carefully to ensure that addressing, device descriptions, communication settings, and cycle-time requirements are consistent across the system.

Process Monitoring and Diagnostics

The CPU can manage operating information and diagnostic data from the automation station. These values can be used by HMI or supervisory systems to display equipment status and help maintenance personnel identify abnormal operating conditions.

The quality of diagnostics depends on the PLC program, the connected devices, and the diagnostic configuration.

Industrial Applications

The Siemens 6AG1315-2EH14-7AB0 is designed for industrial automation applications requiring S7-300 processing capabilities and extended environmental specifications.

1. Manufacturing Production Lines

Manufacturing facilities use PLC controllers to coordinate machinery, production sequences, and material movement.

The CPU can manage conveyor logic, machine interlocks, production counters, and communication with distributed I/O stations.

Its PROFINET and PROFIBUS DP interfaces support integration with compatible automation equipment used across production areas.

2. Process Automation

Industrial process systems often require continuous monitoring and coordinated control of pumps, valves, motors, and instrumentation.

The CPU can execute the control logic used to manage these devices and exchange process information with distributed stations.

Typical applications include auxiliary process equipment, material handling, and machine-level process control.

3. Packaging Machinery

Packaging equipment requires coordinated control of feeding systems, conveyors, sensors, actuators, and operating sequences.

The CPU can process sensor inputs and execute the logic required to synchronize different machine sections.

Communication with compatible remote I/O and operator interfaces helps organize the overall control architecture.

4. Water and Wastewater Equipment

Water treatment and wastewater installations use PLC systems to coordinate pumps, valves, level switches, and process instruments.

The CPU can manage equipment sequencing, alarms, operating states, and communication with remote I/O stations.

The conformal coating and extended temperature specification may be relevant in appropriately engineered installations where environmental conditions require additional protection.

5. Energy and Utility Systems

Industrial utility systems may use PLC controllers to manage auxiliary equipment, monitoring functions, and automated operating sequences.

The CPU can coordinate compatible electrical and mechanical equipment through its available communication interfaces and distributed I/O architecture.

6. Environmental and Extended-Temperature Installations

The SIPLUS configuration is designed for extended environmental conditions compared with standard S7-300 CPU configurations.

Its specified operating temperature range of -25 to +70°C and conformal coating make it relevant to selected installations exposed to challenging temperature conditions.

The complete installation must still comply with the CPU’s environmental limits and the requirements of the connected equipment.

Installation and System Integration

Correct installation and configuration are important for maintaining reliable PLC operation.

1. Verify the Power Supply

The CPU operates from a nominal 24 V DC supply, with a permissible range of 20.4–28.8 V DC.

The rated current consumption is 750 mA, while typical no-load consumption is approximately 150 mA.

Select a suitable power supply with adequate capacity for the CPU and other connected modules. Siemens recommends a minimum 2 A external protection arrangement for the power supply lines, subject to the applicable installation requirements.

2. Install the CPU in the S7-300 System

The CPU must be installed in a compatible SIMATIC S7-300 mounting and backplane arrangement.

Check the rack configuration, module positions, power supply arrangement, and compatibility of the connected modules before installation.

Ensure that the mounting environment provides sufficient mechanical support and appropriate electrical grounding.

3. Connect the Communication Interfaces

The MPI/PROFIBUS DP interface should be configured according to the connected network devices and communication requirements.

The PROFINET interface requires appropriate Ethernet cabling, network addressing, and device configuration.

For installations using distributed I/O, verify the bus topology, device addresses, and communication settings before commissioning.

4. Install the Micro Memory Card

A compatible Siemens Micro Memory Card is required for load-memory storage.

Before inserting or replacing the card, follow the relevant operating instructions and ensure that the program and configuration data are available.

When replacing a CPU, confirm that the memory card contains the correct project data and is suitable for the replacement hardware.

5. Configure the CPU Using STEP 7

The CPU is engineered using STEP 7 V5.5 or higher.

During configuration, engineers define the hardware arrangement, communication interfaces, device addresses, program blocks, and required system parameters.

The configured hardware must match the actual rack and connected devices. Inconsistent hardware configurations may cause diagnostic errors or prevent normal startup.

6. Commission and Test the Automation Station

After installation, verify the power supply, CPU status indicators, memory-card condition, and communication connections.

Test the PLC program, input and output signals, remote I/O communication, and PROFINET connections.

Document the final configuration and retain a backup of the engineering project for future maintenance.

Compatible System Components

The 6AG1315-2EH14-7AB0 is designed to operate within a compatible SIMATIC S7-300 automation system.

Component Function Integration Considerations
SIMATIC S7-300 mounting rack Supports the CPU and system modules Confirm rack and module compatibility
24 V DC power supply Provides operating power Verify current capacity and protection
Siemens Micro Memory Card Stores load memory and user program Required for CPU operation
S7-300 digital input modules Acquire signals from sensors and switches Confirm electrical signal type and module compatibility
S7-300 digital output modules Control actuators and switching devices Check output ratings and load requirements
S7-300 analog input modules Acquire analog process measurements Confirm signal ranges and channel configuration
S7-300 analog output modules Provide analog control signals Verify output type and connected equipment
PROFIBUS DP devices Support distributed communication Configure bus addresses and transmission settings
PROFINET devices Provide Ethernet-based industrial communication Verify network topology and device configuration
HMI panels Display process information and operator controls Configure compatible communication and tags
STEP 7 engineering software Configures and programs the CPU Version 5.5 or higher required

The actual components required depend on the machine architecture and the installed S7-300 configuration. Compatibility should be checked against the relevant hardware and engineering documentation.

Alternative Models and Replacement Considerations

When replacing the 6AG1315-2EH14-7AB0, engineers should compare the full order number and hardware specifications rather than relying only on the CPU 315 designation.

Alternative Model Description Replacement Considerations
6ES7315-2EH14-0AB0 SIMATIC S7-300 CPU 315-2 PN/DP Base model, but does not automatically provide the same SIPLUS environmental configuration
6AG1315-2AH14-7AB0 SIPLUS S7-300 CPU 315-2 DP Different communication configuration; verify network requirements
6AG1317-2EK14-7AB0 SIPLUS S7-300 CPU 317-2 PN/DP Different processing and memory capabilities; assess system compatibility
6ES7314-6EH04-0AB0 SIMATIC S7-300 CPU 314C-2 PN/DP Different CPU configuration and integrated I/O characteristics
6ES7318-3EL01-0AB0 SIMATIC S7-300 CPU 319-3 PN/DP Higher-performance S7-300 option, requiring engineering compatibility review

Before selecting a replacement, verify:

  • CPU processing and memory requirements.
  • MPI/PROFIBUS DP communication requirements.
  • PROFINET interface and network topology.
  • Firmware and hardware revision.
  • Micro Memory Card compatibility.
  • STEP 7 project compatibility.
  • S7-300 rack and module configuration.
  • Environmental temperature and coating requirements.
  • Existing PLC program and communication settings.

A standard S7-300 CPU may provide similar processing functions but may not offer the same environmental protection as the SIPLUS version.

Key Advantages

Extended Temperature Range

The specified operating range of -25 to +70°C supports selected installations exposed to wider temperature variations than conventional indoor control cabinets.

Conformal Coating

The conformal coating provides additional protection for electronic assemblies against specified environmental influences. It does not eliminate the need for appropriate enclosure design and installation practices.

Dual Communication Capability

The combination of MPI/PROFIBUS DP and Ethernet PROFINET supports communication with different types of industrial automation equipment.

384 KB Work Memory

The integrated work memory provides resources for PLC program execution and associated process data management.

Integrated Two-Port PROFINET Switch

The two-port switch supports convenient Ethernet network connections and helps simplify certain network arrangements.

Established S7-300 Platform

The CPU belongs to the widely deployed SIMATIC S7-300 family, making it relevant to existing industrial systems and maintenance projects.

Maintenance-Free Memory Backup

The Micro Memory Card provides program and data retention under the specified conditions without requiring a battery for this backup function.

Technical FAQs

1. What is the Siemens 6AG1315-2EH14-7AB0?

It is a SIPLUS S7-300 CPU 315-2 PN/DP central processing unit based on the 6ES7315-2EH14-0AB0. It provides PLC processing, MPI/PROFIBUS DP communication, and Ethernet PROFINET connectivity.

2. What is the difference between 6AG1315-2EH14-7AB0 and 6ES7315-2EH14-0AB0?

The 6AG1315-2EH14-7AB0 is the SIPLUS version with conformal coating and an extended operating temperature range of -25 to +70°C. The 6ES7315-2EH14-0AB0 is the corresponding standard SIMATIC S7-300 CPU model.

3. How much work memory does this CPU have?

It has 384 KB of integrated work memory. The load memory uses a Siemens Micro Memory Card with a maximum supported capacity of 8 MB.

4. Which communication protocols does it support?

The CPU supports MPI and PROFIBUS DP through its first interface and Ethernet PROFINET through its second interface. The PROFINET interface includes an integrated two-port switch.

5. What power supply does the CPU require?

It requires 24 V DC. The permissible supply range is 20.4–28.8 V DC.

6. Which programming software is required?

The CPU is engineered using Siemens STEP 7 V5.5 or higher. The engineering project must match the CPU hardware and firmware requirements.

7. Is a Micro Memory Card required?

Yes. A Siemens Micro Memory Card is required for load-memory storage. The card stores the user program and associated data.

8. What is the operating temperature range?

The specified operating temperature range is -25 to +70°C. This extended range is one of the main characteristics of the SIPLUS version.

9. Can this CPU communicate with distributed I/O modules?

Yes. It can communicate with compatible distributed I/O equipment through PROFIBUS DP and PROFINET, subject to the system configuration and device compatibility.

10. Can it directly replace a standard CPU 315-2 PN/DP?

Not without checking the complete system configuration. Although it is based on the standard CPU 315-2 PN/DP, engineers should verify environmental requirements, firmware, hardware revision, memory-card compatibility, network settings, and the existing STEP 7 project before replacement.

Procurement and Maintenance Recommendations

When purchasing the Siemens 6AG1315-2EH14-7AB0, verify the complete order number and confirm that the SIPLUS version is required. The environmental characteristics are important, particularly when the installation operates outside the temperature range of a standard S7-300 CPU.

For new, surplus, or refurbished units, check the product label, hardware revision, connector condition, housing, and status indicators. Confirm whether the Micro Memory Card is included, as it is required for load-memory storage but may not be supplied with every unit.

Before replacing an installed CPU, back up the STEP 7 project and document the hardware configuration, communication parameters, and program version. Confirm that the replacement CPU can operate with the existing S7-300 rack and connected modules.

For ongoing maintenance, keep the control cabinet clean, maintain suitable ventilation, and inspect power connections and communication cables periodically. Retain a verified copy of the PLC program and configuration data to support recovery after equipment replacement or unexpected failure.

Conclusion

The Siemens 6AG1315-2EH14-7AB0 SIPLUS S7-300 CPU 315-2 PN/DP is a central processing unit designed for industrial automation applications requiring PLC control, distributed communication, and extended environmental capability.

With 384 KB of work memory, MPI/PROFIBUS DP communication, Ethernet PROFINET connectivity, conformal coating, and an operating temperature range of -25 to +70°C, it provides a specialized controller configuration for compatible S7-300 installations.

For maintenance, procurement, and system integration, engineers should verify the complete order number, Micro Memory Card requirements, communication configuration, and environmental specifications before installation or replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501