Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric TM3RDM32R Discrete I/O Module is a mixed digital input and relay output expansion module designed for industrial automation systems based on the Modicon Easy M200 logic controller. As part of the Modicon TM3 expansion range, it increases the number of digital signals that a controller can monitor and manage, allowing additional sensors, switches, actuators, and other field devices to be integrated into a machine-control system.
The TM3RDM32R provides 32 digital I/O points in one compact unit. Its configuration consists of 16 digital inputs and 16 relay outputs. The inputs accept 24 V DC signals and support sink or source wiring arrangements. The relay outputs use normally open contacts and can switch compatible 24 V DC or 240 V AC loads within the specified electrical limits.
This combination of input and output channels makes the module suitable for applications that require both signal acquisition and discrete equipment control. For example, a machine controller can receive signals from limit switches, proximity sensors, and push buttons while using relay outputs to operate indicator devices, contactor coils, and other compatible loads.
The module features removable screw terminal blocks, individual channel status LEDs, and a compact housing designed for DIN rail or panel mounting. Its mechanical design supports straightforward installation and maintenance in appropriately designed control cabinets.
The TM3RDM32R is specifically designed for the Modicon Easy M200 controller range. System designers should verify controller compatibility before installation because not every TM3 expansion module is suitable for every Modicon controller family.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Model | TM3RDM32R |
| Product Series | Modicon TM3 |
| Product Type | Discrete I/O Module |
| Module Configuration | 32-point mixed digital I/O |
| Total I/O Points | 32 |
| Digital Input Channels | 16 |
| Digital Output Channels | 16 |
| Input Voltage | 24 V DC |
| Input Standard | IEC 61131-2 Type 1 |
| Input Logic | Sink or Source |
| Input Current | 5 mA per input |
| Input Impedance | 4.7 kΩ |
| Input Response Time | 4 ms ON / 4 ms OFF |
| Output Type | Normally Open Relay |
| Output Voltage | 24 V DC / 240 V AC |
| Maximum Output Current | 2 A per output |
| Maximum Current per Common | 4 A |
| Output Status Indication | Green LED per channel |
| Input Status Indication | Green LED per channel |
| Electrical Connection | Removable screw terminal blocks |
| Input Terminal Block | 9 × 1.5 mm² |
| Output Terminal Block | 11 × 1.5 mm² |
| Terminal Pitch | 3.81 mm |
| Mounting | TH35 DIN Rail / Panel Mounting |
| Protection Rating | IP20 |
| Operating Temperature | 0 to +55°C, horizontal installation |
| Storage Temperature | -25 to +70°C |
| Dimensions | 90 × 84.6 × 51 mm |
| Weight | 0.208 kg |
| Controller Compatibility | Modicon Easy M200 |
The TM3RDM32R combines digital signal acquisition and relay-based output switching in one expansion module. It communicates with a compatible controller through the Modicon TM3 expansion bus, allowing the controller program to read input states and operate output channels.
The module provides 16 digital input channels designed for 24 V DC signals. These channels receive discrete signals from field devices such as:
Each input detects whether its electrical signal represents an ON or OFF condition. The module then makes the corresponding input state available to the controller.
The inputs support sink or source wiring arrangements, providing flexibility when connecting different types of field devices. The input logic and common-terminal arrangement must be selected according to the actual wiring design.
The module contains 16 normally open relay output channels. These outputs allow the controller to switch compatible external electrical loads.
When the controller activates an output, the corresponding relay contact changes state and completes the external circuit. When the output is deactivated, the normally open contact returns to its open condition.
Relay outputs can be used with compatible 24 V DC and 240 V AC circuits, subject to the module’s ratings and the characteristics of the connected load.
The maximum current is 2 A per output, while the maximum current per common group is 4 A. Both limits must be respected when designing output circuits.
The TM3RDM32R exchanges digital I/O information with the compatible logic controller through the TM3 expansion bus.
Input information is transferred to the controller so that the user program can evaluate machine conditions. Output commands from the controller are transmitted to the module, which operates the corresponding relay channels.
This arrangement allows additional field devices to be incorporated without requiring every signal to be connected directly to the controller’s built-in I/O terminals.
Individual green LEDs provide local indication of I/O channel states. During commissioning and maintenance, technicians can use these indicators to help identify whether an input signal has been detected or an output channel has been commanded.
LED indication is useful for troubleshooting, but it should not be treated as a complete electrical test. When a field device or connected load fails to operate, technicians should also inspect wiring, supply voltage, terminal connections, and the external circuit.
The TM3RDM32R functions as an I/O expansion component within a compatible Modicon control architecture. It connects field-level electrical signals with the controller program, helping the automation system monitor equipment conditions and execute machine-control sequences.
A logic controller has a limited number of built-in I/O points. As a machine becomes more complex, additional inputs and outputs may be required for sensors, switches, relays, and actuators.
The TM3RDM32R adds 16 digital inputs and 16 relay outputs, allowing a compatible M200 controller to manage more field devices.
Input channels can receive signals representing machine conditions, including:
The controller program can evaluate these signals and determine whether the machine should continue operating, change sequence, or enter a controlled stop condition.
The module itself is not a safety-rated controller or safety I/O device. Safety functions must be implemented using appropriately rated safety equipment and an approved safety architecture.
The 16 relay outputs can control compatible external circuits. Depending on the electrical design, these may include indicator lamps, interface relays, contactor coils, and other discrete loads.
For larger or inductive loads, suitable external switching devices and suppression components may be required. The module’s relay contacts should not be used beyond their specified electrical ratings.
The module allows a controller to combine input feedback and output commands in a coordinated sequence. For example, a packaging machine may detect product position through input channels and activate a pneumatic valve or signaling circuit through an output channel.
This arrangement supports orderly machine operation and helps reduce the need for separate expansion hardware for different signal types.
The Schneider Electric TM3RDM32R is suitable for discrete control applications where a compatible Modicon Easy M200 controller requires additional digital inputs and relay outputs.
Packaging equipment uses multiple sensors and discrete actuators to manage product movement, positioning, and machine sequences.
The 16 input channels can receive signals from product-detection sensors, limit switches, and operator controls. The relay outputs can operate compatible external control circuits for indicators, interface relays, or other machine functions.
Conveyor installations often require signals from photoelectric sensors, position switches, and motor-status contacts.
The TM3RDM32R can collect these signals and provide relay outputs for compatible auxiliary circuits. A PLC program can use the collected information to coordinate conveyor movement and material transfer.
Assembly equipment may contain multiple stations, each with sensors and electrically controlled components.
The module can provide additional I/O capacity for station detection, fixture confirmation, machine-status feedback, and discrete control commands. This helps the controller manage a more detailed production sequence.
Material-handling systems use sensors and switches to identify the position and status of moving equipment.
The module can receive signals from position switches and product sensors while controlling compatible relay circuits used by auxiliary equipment. The actual load current and switching frequency must remain within the module’s limits.
Small and medium-sized machines often require a combination of digital signal acquisition and relay output switching.
The TM3RDM32R can support machine control in suitable manufacturing applications, including inspection stations, compact processing equipment, and automated workstations.
Correct installation is essential for reliable operation and protection of the module and connected equipment.
Before installation, confirm that the controller supports the TM3RDM32R. This module is specifically designed for the Modicon Easy M200 controller range.
Do not assume that mechanical compatibility with a TM3 expansion connector guarantees compatibility with every Modicon controller. Check the controller hardware documentation and supported expansion configuration.
The module can be mounted on compatible TH35 DIN rails or installed on a panel using the appropriate fixing arrangement.
Its dimensions are 90 × 84.6 × 51 mm, with a weight of 0.208 kg. Allow sufficient cabinet space for terminal access, wiring bends, ventilation, and maintenance.
The module has an IP20 protection rating and should be installed inside a suitable control enclosure. Avoid exposure to water, conductive dust, excessive vibration, or corrosive substances.
Connect the 24 V DC field devices to the designated input terminals. Select the appropriate sink or source wiring arrangement and follow the module’s terminal diagram.
Observe the input common-terminal arrangement carefully. The input common connections are not interchangeable with output common terminals.
Use suitable conductor sizes and ensure that all terminal screws are tightened according to the installation instructions.
Connect external loads to the designated relay output terminals. Each output is a normally open relay contact and must be used within its rated voltage and current limits.
The maximum current is 2 A per output, with a maximum of 4 A per common group. The total current through a common group must not exceed this limit, even if individual output currents are each below 2 A.
For inductive DC loads, use an appropriate freewheeling diode or other suitable suppression device. For inductive AC loads, an appropriate RC snubber may help reduce contact stress.
Install the module in the supported expansion arrangement and ensure that the TM3 bus connectors are correctly engaged.
After installation, verify that the controller recognizes the expansion module and that the configured I/O addresses correspond to the intended input and output channels.
Before putting the machine into operation, test each input channel with its corresponding field device. Confirm that the controller program detects the correct ON and OFF states.
Test each relay output using a suitable load or test arrangement. Verify contact operation, external circuit voltage, common-group current, and connected equipment response.
Document the I/O assignment and wiring information to support future maintenance and troubleshooting.
The TM3RDM32R operates as part of a compatible Modicon control system. The following components may be used in a complete installation, depending on the application.
| Component | Function | Integration Considerations |
|---|---|---|
| Modicon Easy M200 Controller | Executes control logic and manages I/O | Verify supported TM3 expansion configuration |
| 24 V DC Power Supply | Supplies field devices and compatible control circuits | Check current capacity and voltage stability |
| Digital Proximity Sensors | Detect objects and machine positions | Match sensor output type to input wiring |
| Photoelectric Sensors | Detect products and material movement | Confirm 24 V DC signal compatibility |
| Limit Switches | Provide position and travel feedback | Verify contact arrangement and wiring |
| Interface Relays | Isolate or adapt external control circuits | Select suitable coil voltage and contact ratings |
| Contactors | Switch compatible motor power circuits | Use suitable external protection and coil suppression |
| HMI | Provides operator commands and machine status | Communicate through the supported controller architecture |
| Control Cabinet | Houses controller and I/O equipment | Provide appropriate IP protection and wiring space |
The components listed above are examples of equipment that may be used in a system. They are not necessarily included with the TM3RDM32R module.
When replacing the TM3RDM32R, engineers should compare the complete electrical configuration rather than selecting another module based only on its total I/O count.
| Related Model or Option | Main Difference | Replacement Consideration |
|---|---|---|
| Schneider TM3RDM16R | Mixed digital I/O with fewer channels | Different I/O capacity and channel arrangement |
| Schneider TM3DM24R | 16 digital inputs and 8 relay outputs | Different output count and controller compatibility requirements |
| Schneider TM3DM8R | Compact mixed I/O module | Lower channel capacity |
| Schneider TM3DI16G | Digital input expansion module | Input-only design; no relay outputs |
| Schneider TM3DQ16R | Relay output expansion module | Output-only design; no digital input channels |
Before selecting a replacement, verify:
A module with the same number of total I/O points may have a different combination of input and output channels. Confirm the actual signal requirements before changing the hardware.
The module combines 16 digital inputs and 16 relay outputs in one compact unit, supporting applications that require both signal acquisition and discrete switching.
The digital inputs support sink and source wiring arrangements, allowing integration with suitable 24 V DC field devices.
The normally open relay outputs support compatible 24 V DC and 240 V AC circuits within their specified current limits.
Green LEDs provide local channel-state information, helping technicians during installation, commissioning, and troubleshooting.
The removable terminal blocks simplify wiring work and can make module replacement more convenient during maintenance.
The module’s 90 × 84.6 × 51 mm dimensions support installation in appropriately designed industrial control cabinets.
The TM3RDM32R provides additional digital I/O capacity for compatible Modicon Easy M200 controller configurations.
The TM3RDM32R is a Modicon TM3 mixed digital I/O expansion module. It provides 16 digital inputs and 16 relay outputs, giving the system 32 I/O points.
It has 16 digital input channels. These inputs are designed for 24 V DC signals and support sink or source wiring arrangements.
The module provides 16 normally open relay outputs. They can switch compatible 24 V DC or 240 V AC loads within the specified electrical ratings.
The maximum current is 2 A per relay output. The maximum current per common group is 4 A. Both limits must be respected when connecting external loads.
The module is specifically designed for the Modicon Easy M200 controller range. Verify the supported hardware configuration before installation.
Yes. Its 24 V DC digital inputs support sink or source wiring arrangements. The correct configuration depends on the connected field devices and wiring design.
It uses removable screw terminal blocks. The input terminal block is specified for 9 × 1.5 mm² conductors, while the output terminal block is specified for 11 × 1.5 mm² conductors, with a 3.81 mm pitch.
The module provides one green LED per channel for local I/O state indication. These indicators help identify input and output states during commissioning and troubleshooting.
The specified operating temperature range is 0 to +55°C for horizontal installation. The module should be installed in an enclosure that maintains suitable environmental conditions.
Confirm controller compatibility, the 16-input and 16-output arrangement, input voltage, relay ratings, common-group current limits, terminal connections, and I/O addressing. A replacement with a different channel configuration may require wiring and program changes.
When purchasing the Schneider Electric TM3RDM32R, verify the complete model number and confirm that the module is suitable for the intended Modicon Easy M200 controller configuration.
For replacement projects, compare the input and output channel arrangement with the installed module. Confirm that the connected field devices use compatible 24 V DC signals and that relay loads remain within the 2 A per-channel and 4 A per-common limits.
For used or surplus units, inspect the housing, terminal blocks, bus connectors, mounting clips, and channel indicators. Request clear product photographs and confirm the unit’s condition before ordering. For critical production equipment, functional testing should be considered before installation.
During routine maintenance, inspect terminal tightness, field wiring, electrical connections, and the condition of external loads. Check for signs of overheating, contamination, or mechanical damage. Inductive loads should have appropriate suppression to reduce electrical stress on relay contacts.
Keep the controller configuration and I/O assignment documentation updated. This helps technicians identify each channel and reduces the risk of wiring errors during future maintenance or module replacement.
The Schneider Electric TM3RDM32R Modicon TM3 Discrete I/O Module is a 32-point mixed I/O expansion device featuring 16 digital inputs and 16 normally open relay outputs. Its 24 V DC input configuration, relay switching capability, removable screw terminals, and individual channel indicators make it suitable for a range of compact industrial automation applications.
Designed specifically for compatible Modicon Easy M200 controllers, the TM3RDM32R provides additional signal acquisition and output control capacity for machine automation systems. Correct controller selection, electrical wiring, load protection, and I/O configuration are essential for reliable operation.