Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric LC1D475M7C TeSys D Contactor is a heavy-duty three-pole electrical switching device designed for controlling high-current industrial loads. As part of the Schneider Electric TeSys D contactor family, it is used in motor-control circuits, industrial power distribution assemblies, and electrical switching applications requiring reliable operation under demanding conditions.
A contactor is an electrically controlled switching device. When its coil receives the specified control voltage, an electromagnetic mechanism operates the main contacts, allowing the connected power circuit to be switched on or off. This arrangement enables a control system to operate motors and other electrical loads without requiring the control circuit to carry the full load current.
The LC1D475M7C features three normally open main poles and a 220 V AC control coil rated for 50/60 Hz operation. Its rated operational current is 475 A under AC-3 conditions at up to 440 V AC, while its AC-1 rating is 700 A under the specified operating conditions. These ratings make it suitable for applications involving substantial electrical loads, provided the contactor is selected according to the actual load category and installation requirements.
The device is designed for motor control and resistive-load switching. Its electromagnetic operating mechanism provides a way to coordinate high-current power circuits with lower-voltage control systems, including PLC-based automation and industrial motor-control panels.
The full catalog number is important when ordering this contactor. The suffix M7C identifies the 220 V AC, 50/60 Hz coil configuration. A contactor with a similar current rating but a different coil voltage may not operate correctly in the existing control circuit.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | TeSys D |
| Model | LC1D475M7C |
| Product Type | AC Contactor |
| Device Short Name | LC1D |
| Number of Poles | 3P |
| Main Contact Configuration | 3 Normally Open (3NO) |
| AC-3 Rated Operational Current | 475 A |
| AC-1 Rated Operational Current | 700 A |
| Control Coil Voltage | 220 V AC |
| Coil Frequency | 50/60 Hz |
| Rated Operational Voltage | Up to 1000 V AC, subject to utilization category and operating conditions |
| Main Applications | Motor control and resistive-load switching |
| Mechanical Durability | Approximately 8 million operating cycles |
| Electrical Durability | Depends on utilization category and operating conditions |
| Installation | Industrial electrical panel or suitable mounting arrangement |
| Dimensions Provided | 233 × 238 × 232 mm |
| Weight Provided | 11.62 kg |
| Product Weight Reference | Approximately 12.5 kg in the referenced product specification |
| Typical Use | Industrial motor-control and power-switching systems |
Note: The supplied dimensions correspond to the manufacturer’s listed dimensions of approximately 238 mm high, 233 mm wide, and 232 mm deep, with a different order of presentation. The supplied 11.62 kg figure is identified as packaging weight in the referenced product information; the product weight is listed separately at approximately 12.5 kg. Confirm the actual unit and shipping data before procurement.
The LC1D475M7C uses an electromagnetic operating mechanism to switch its three main power contacts. Its operation is controlled by the voltage applied to the coil.
When 220 V AC is applied to the contactor coil, current flows through the coil and creates a magnetic field. This magnetic field attracts the movable armature, operating the contact mechanism and closing the three normally open main contacts.
When the coil is de-energized, the magnetic field collapses and the return mechanism moves the contacts back to their open position.
This allows a relatively low-power control circuit to operate a high-current power circuit.
The contactor contains three main poles for switching a three-phase electrical circuit. In a typical motor-control installation, each pole is connected to one phase of the supply.
When the contactor operates, all three main contacts are mechanically coordinated. This allows the three-phase motor supply to be connected or disconnected through a single control device.
The contactor should be used with suitable upstream short-circuit protection and motor overload protection. It is not a substitute for a circuit breaker or a dedicated motor-protection device.
In a conventional direct-on-line motor starter, the contactor connects the motor to the power supply when a start command is received. A stop command or protective trip can de-energize the coil and disconnect the motor from the supply.
The LC1D475M7C can serve as the main switching component in an appropriately engineered motor starter. Its selection must account for motor power, full-load current, starting frequency, utilization category, and expected electrical life.
The 220 V AC coil allows the contactor to be operated by a compatible control circuit. Depending on the system design, the coil may be controlled through pushbuttons, relay logic, a PLC output interface, or an intermediate control relay.
The control circuit must be designed to supply the correct coil voltage and accommodate the coil’s operating characteristics. A PLC output should not be connected directly unless its electrical rating and switching arrangement are suitable.
The contactor’s current rating depends on the utilization category. AC-3 is commonly associated with squirrel-cage motor starting and switching during normal motor operation. AC-1 applies to non-inductive or slightly inductive resistive loads.
The 475 A AC-3 and 700 A AC-1 ratings should therefore not be treated as interchangeable. Selection must be based on the actual load type and operating conditions.
The LC1D475M7C can function as a major switching component within an industrial electrical control panel. It connects the power circuit to the load according to commands from the control system.
A programmable logic controller can coordinate the contactor with sensors, process conditions, safety interlocks, and other equipment. For example, PLC logic may energize the contactor when a machine is ready to operate and remove the command when a stop condition occurs.
The PLC generally operates the contactor through a suitable output interface or intermediate relay. The control circuit must be designed for the contactor’s 220 V AC coil.
The contactor can be integrated into a motor starter with appropriately rated overload protection and short-circuit protective devices. The complete starter assembly provides the switching and protection functions required for the connected motor.
The contactor itself performs the switching function; overload and short-circuit protection must be provided by suitable associated equipment.
An HMI can provide operators with start and stop commands, operating status, and fault information. In a PLC-based system, the HMI typically communicates with the PLC, which controls the contactor through the appropriate output circuit.
This arrangement allows operators to manage motor operation from a central interface while maintaining control logic and interlocks within the automation system.
The LC1D475M7C may also be used in industrial switching assemblies where its ratings and utilization category are appropriate. Engineers should consider the connected load, switching frequency, ambient temperature, enclosure conditions, and available short-circuit protection.
The LC1D475M7C is intended for applications requiring high-current switching. Its actual suitability depends on the electrical characteristics of the load and the contactor’s utilization category.
Large industrial motors are commonly controlled through contactor-based starter assemblies. The LC1D475M7C can serve as the main switching device in a suitable three-phase motor circuit.
It may be used in equipment such as pumps, compressors, conveyors, and other machinery where the motor current and starting conditions fall within the contactor’s ratings.
Industrial pumping installations use contactors to connect and disconnect motor power according to process requirements. A PLC or pressure-control system can issue operating commands based on tank level, pressure, or flow conditions.
For pump applications, engineers should verify the motor’s full-load current, starting characteristics, and switching frequency before selecting the contactor.
Industrial compressors may require contactor-based motor switching as part of their electrical control system. The contactor can be coordinated with pressure switches, PLC logic, overload protection, and other control devices.
The compressor’s starting method and operating duty must be evaluated to ensure that the contactor is suitable for the application.
The AC-1 rating is relevant to non-inductive or slightly inductive resistive loads. Depending on the electrical design, the contactor may be used for switching suitable heating equipment and other resistive circuits.
The load current, voltage, ambient temperature, and switching frequency must remain within the applicable ratings.
Manufacturing plants use contactors in machine-control panels, production equipment, utility systems, and auxiliary power circuits. The LC1D475M7C can be considered where a three-pole contactor with a 220 V AC coil and suitable current rating is required.
The complete installation should include appropriate protection, control interlocks, and isolation provisions.
Correct installation is essential for reliable switching, electrical safety, and long-term contactor performance.
Before installation, confirm that the control circuit supplies 220 V AC at 50/60 Hz. The M7C suffix is an important part of the model identification and should be checked against the existing contactor.
Do not substitute a contactor with a different coil voltage unless the control circuit is specifically modified and approved for that configuration.
Check the load type and select the applicable utilization category. For motor applications, verify the motor’s rated voltage, full-load current, starting conditions, and operating duty.
The 475 A AC-3 rating applies under the specified conditions and should not be used as a general current rating for every load type.
The supplied dimensions are 233 × 238 × 232 mm. Confirm the manufacturer’s dimensional drawing and terminal-access requirements before designing the mounting arrangement.
Provide adequate space for cable connections, conductor bending, heat dissipation, inspection, and maintenance. The contactor should be mounted in a suitable enclosure that protects it from environmental conditions outside its permitted operating range.
Connect the three main poles according to the wiring diagram and terminal markings. Use conductors, terminals, and connection hardware rated for the operating current and installation conditions.
The coil circuit should be wired separately from the main power circuit as appropriate. Maintain correct insulation, grounding, conductor identification, and separation practices.
A contactor does not provide complete motor protection. The installation should include suitable short-circuit protection and overload protection selected for the connected motor and system.
Protective devices must be coordinated with the contactor and the available fault current. Follow the applicable Schneider Electric documentation and local electrical standards.
After installation, inspect the mechanical mounting, terminal connections, and coil wiring. Apply the correct control voltage and verify that the contactor operates smoothly.
Test the start and stop commands, interlocks, overload trip response, and emergency-stop control arrangement. Confirm that all three main poles switch correctly and that there is no abnormal heating, vibration, or contact chatter during operation.
The LC1D475M7C is commonly used with other electrical control and protection equipment in a complete motor-control assembly.
| Component | Function | Integration Considerations |
|---|---|---|
| Three-phase AC motor | Converts electrical energy into mechanical power | Verify full-load current, voltage, and starting conditions |
| Motor overload relay | Protects the motor against sustained overload | Select according to motor current and starter design |
| Circuit breaker or fuse | Provides short-circuit protection | Coordinate with the contactor and available fault current |
| PLC | Executes machine-control logic | Use a suitable output interface for the 220 V AC coil circuit |
| Intermediate control relay | Interfaces PLC outputs with the contactor coil | Verify coil voltage and switching capacity |
| HMI | Provides operator commands and status display | Usually communicates with the PLC |
| Emergency-stop circuit | Initiates the required machine stop function | Design according to the machine’s safety requirements |
| Control transformer or supply | Provides the required control voltage | Ensure a suitable 220 V AC supply for the coil |
| Electrical enclosure | Houses and protects control equipment | Provide suitable dimensions, ventilation, and environmental protection |
The components listed are examples of equipment that may be used in a complete installation. They are not necessarily supplied with the contactor.
When replacing the LC1D475M7C, the replacement should be selected according to the complete electrical specification rather than current rating alone.
| Alternative or Related Option | Replacement Considerations |
|---|---|
| Schneider Electric TeSys D contactor | Confirm the required current rating, pole configuration, coil voltage, and utilization category |
| Schneider Electric TeSys Deca contactor | Review the product generation, mounting, terminal arrangement, and electrical ratings |
| Schneider Electric TeSys F contactor | May be considered for certain high-current applications after detailed engineering review |
| Equivalent three-pole industrial contactor | Must match the AC-3 or AC-1 duty requirements, coil voltage, and installation conditions |
| Complete motor starter assembly | May be appropriate when replacing the contactor and associated protection as a coordinated system |
Before choosing a replacement, compare:
A contactor with a similar current rating may not be a direct replacement. Changes in coil voltage, terminal design, mounting dimensions, and utilization ratings can affect the existing control panel.
The 475 A AC-3 rating supports appropriately selected motor-control applications, while the 700 A AC-1 rating applies to suitable resistive or slightly inductive loads under specified conditions.
The three normally open main poles allow coordinated switching of a three-phase power circuit.
The 220 V AC, 50/60 Hz coil supports integration into compatible industrial control circuits.
The electromagnetic mechanism enables a low-power control circuit to operate a high-current power circuit.
The TeSys D design is intended for motor control and other specified industrial switching duties.
The contactor can be coordinated with PLCs, HMIs, overload relays, protective devices, and other components in a properly engineered control panel.
The complete LC1D475M7C catalog number identifies its main configuration and coil specification, helping maintenance teams distinguish it from similar contactors.
It is a three-pole TeSys D AC contactor designed for industrial motor control and suitable resistive-load switching. It has a 220 V AC, 50/60 Hz control coil.
The LC1D475M7C has an AC-3 rated operational current of 475 A under the specified conditions at up to 440 V AC.
Its AC-1 rated operational current is 700 A under the specified conditions. AC-1 and AC-3 ratings apply to different load categories and should not be interchanged.
The M7C configuration uses a 220 V AC coil rated for 50/60 Hz operation. Always confirm the catalog number and product nameplate before connecting the control circuit.
It has three main poles, configured as three normally open contacts (3NO), for switching a three-phase power circuit.
Yes. A PLC can control the contactor through a suitable output interface or intermediate relay. The interface must be rated for the 220 V AC coil circuit and designed according to the control-system requirements.
No. The contactor performs the switching function. A suitable motor overload relay or other approved protection device must be installed as part of the motor starter.
Verify the complete catalog number, coil voltage, current ratings, utilization category, pole configuration, terminal arrangement, mounting dimensions, and associated protective devices.
The supplied 11.62 kg figure is listed as packaging weight in the referenced product information. The product weight is listed separately at approximately 12.5 kg. Confirm the actual unit weight and shipping weight with the supplier before arranging transport.
It may be used in appropriately rated industrial motor starters, pumping systems, compressor equipment, manufacturing machinery, and suitable resistive-load switching circuits. The final selection must be based on load characteristics and applicable electrical ratings.
When purchasing the LC1D475M7C, verify the complete catalog number and confirm that the coil voltage matches the existing control circuit. For replacement projects, compare the contactor’s AC-3 and AC-1 ratings with the actual load requirements rather than relying on a single current figure.
Request clear photographs of the product label, main terminals, coil terminals, and overall housing when sourcing surplus or used equipment. Confirm the physical condition, contact condition, mechanical operation, and any available test records.
For installation, use conductors and connection hardware suitable for the load current. Ensure that the contactor is coordinated with the correct short-circuit and overload protection. Inspect terminal tightness, contact condition, mechanical operation, and signs of overheating during scheduled maintenance.
Contactors are electromechanical devices with finite mechanical and electrical service lives. Switching frequency, load category, electrical conditions, and maintenance practices all influence their service life. Replace equipment that shows abnormal contact wear, overheating, mechanical damage, or unreliable operation.
For critical applications, maintain a suitable spare unit and record the complete catalog number, coil voltage, installation details, and associated protection settings. This information can reduce troubleshooting time and help avoid incorrect replacement purchases.
The Schneider Electric LC1D475M7C TeSys D Contactor is a three-pole industrial switching device with a 475 A AC-3 rating, a 700 A AC-1 rating, and a 220 V AC, 50/60 Hz control coil. It is designed for motor control and suitable resistive-load switching applications in industrial electrical systems.
Its electromagnetic operating mechanism allows a control circuit to switch a high-current three-phase power circuit. For reliable operation, the contactor must be matched with the correct load category, protective devices, control voltage, and installation arrangement. Accurate catalog-number verification is especially important when sourcing spare parts or replacing an existing contactor.