Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC200MDD845G VersaMax Discrete Mixed I/O Module is an industrial automation component designed to provide both digital input and relay output functions within a single compact module. Part of the GE Fanuc VersaMax I/O family, it allows a PLC or network interface unit to monitor field signals and control external electrical devices through one integrated I/O assembly.
Combining input and output channels in one module can simplify control-panel design and reduce the number of separate I/O modules required for certain applications. The IC200MDD845G provides 16 discrete input points and 8 relay output points, making it suitable for machine-control systems that need to monitor switches, sensors, and status contacts while controlling relays, contactors, indicator lamps, and other compatible loads.
The input section is designed for 24 V DC signals. The output section uses individually isolated Form A relay contacts, supporting a range of AC and DC load voltages within the specified electrical limits. This arrangement gives the module flexibility when interfacing with different types of industrial field devices.
The IC200MDD845G is designed for use in a VersaMax I/O architecture and requires a compatible carrier base. It receives its operating power from the system backplane, while the external loads connected to its relay contacts require an appropriate external power source.
For maintenance and replacement projects, the complete catalog number and hardware revision should be checked before installation. Compatibility depends on the carrier base, controller or network interface, wiring arrangement, and the electrical requirements of the connected field devices.
| Parameter | Specification |
|---|---|
| Brand | GE |
| Manufacturer | GE Fanuc / GE Intelligent Platforms |
| Product Series | VersaMax |
| Model | IC200MDD845G |
| Product Type | Discrete Mixed I/O Module |
| Input Channels | 16 points |
| Output Channels | 8 points |
| Total I/O Points | 24 |
| Input Signal Type | 24 V DC discrete input |
| Input Voltage Range | 0–30 V DC |
| Input Logic | Positive/negative logic support depends on hardware revision |
| Output Type | Form A relay contacts |
| Output Isolation | Individually isolated output channels |
| Maximum AC Output Voltage | 265 V AC |
| Maximum DC Output Voltage | 125 V DC |
| Maximum Resistive Load Current | 2.0 A within specified voltage ranges |
| Maximum Load at 31–125 V DC | 0.2 A |
| Minimum Load Current | 10 mA per point |
| Backplane Current Consumption | 270 mA maximum at 5 V |
| Input Response Time | 0.5 ms maximum before configurable filtering |
| Output Response Time | Approximately 10 ms maximum |
| Status Indicators | Individual channel LEDs and OK LED |
| Mounting | Compatible VersaMax carrier base |
| Dimensions Provided | 110 × 66.8 × 50 mm |
| Weight Provided | 0.27 kg |
| Typical Applications | PLC digital signal acquisition and relay-based field control |
Note: The dimensions and weight are the supplied listing values. Confirm the exact hardware revision and physical unit before finalizing technical documentation. Output ratings depend on voltage, load type, and operating conditions.
The IC200MDD845G combines two different signal-handling functions: digital input acquisition and relay-based output control. The input section receives binary signals from field devices, while the output section switches external circuits through relay contacts.
The module provides 16 discrete input channels for monitoring field devices such as:
Each input represents a binary condition. Depending on the electrical signal, the channel is interpreted as ON or OFF by the PLC or network interface.
The input section is designed for nominal 24 V DC signals. Correct polarity, common connections, and signal voltage must be observed during wiring.
The module provides eight Form A relay output channels. Form A contacts are normally open contacts that close when the corresponding output is activated.
These outputs can be used to switch compatible external circuits, including:
Each output channel is individually isolated. This provides separation between output channels and helps accommodate different external circuits within the module’s specified electrical limits.
The relay contacts do not generate the power required by the connected load. An appropriate external supply must be provided.
The module allows a controller to acquire input information and issue output commands through a single I/O assembly.
For example, a PLC may receive a signal from a machine limit switch through one of the input channels. After evaluating the control logic, it can activate a relay output to operate an indicator or a contactor control circuit.
This arrangement supports straightforward control sequences and can reduce the need for separate input-only and relay-output modules.
The relay outputs provide individual channel isolation. This is useful when the module controls several external circuits that require separate electrical connections.
The specified isolation ratings and wiring requirements must be followed. Isolation does not remove the need for correct grounding, overcurrent protection, and safe separation of different voltage circuits.
The module includes individual channel indicators and an OK indicator.
The channel LEDs help maintenance personnel identify the logical state of input and output points. The OK LED indicates that backplane power is present.
An output LED represents the module’s logic state and should not be treated as direct confirmation that the external load is operating correctly. External circuit testing may still be required.
The IC200MDD845G functions as an interface between a PLC control system and field-level electrical devices. It converts field input conditions into digital information and switches external loads according to commands from the controller.
A VersaMax controller or compatible network interface unit processes the module’s input and output data.
The controller can monitor input conditions, execute programmed logic, and update the relay output states. This makes the module suitable for machine sequencing, equipment status monitoring, and auxiliary control functions.
The module provides 16 input bits and 8 output bits to the host control system. Actual integration depends on the installed controller, carrier base, system configuration, and supported firmware.
The 16 input channels can collect status information from different parts of a machine. Examples include guard switches, position switches, motor auxiliary contacts, and operating push buttons.
The controller can use these signals to determine whether a machine is ready to operate, whether a process step has been completed, or whether an abnormal condition requires attention.
The eight relay outputs allow the controller to switch compatible external circuits. They can be used for auxiliary control functions such as operating indicator lamps, enabling interposing relays, or switching suitable contactor control circuits.
For inductive loads, appropriate external suppression and protection should be considered. The module does not include internal fuses or snubbers, so the external circuit must be designed accordingly.
VersaMax supports modular and distributed I/O configurations. Depending on the system architecture, the IC200MDD845G can be installed in an appropriate local or remote I/O arrangement.
This helps engineers position signal interfaces near the equipment being controlled and organize field wiring according to the plant layout.
The GE IC200MDD845G is suitable for applications that require a combination of 24 V DC discrete signal acquisition and relay-based output switching.
Production machines often contain numerous switches and actuators. The module can monitor operating conditions through its input channels and control compatible auxiliary circuits through its relay outputs.
Typical signals include machine-position switches, operator push buttons, equipment-ready contacts, and auxiliary relay circuits.
Conveyor installations use sensors and switches to monitor material movement and equipment status.
The input channels can receive signals from compatible limit switches and other discrete devices. The relay outputs can control suitable auxiliary circuits, such as indicator lamps or interposing relays used in conveyor sequencing.
Packaging machines require coordination between product detection, machine-position feedback, and auxiliary control devices.
The IC200MDD845G can provide input monitoring and relay output functions for suitable parts of a packaging control system. The PLC program determines how the input conditions affect the output commands.
Industrial pump and motor installations use auxiliary contacts to indicate operating status, overload conditions, and control-circuit states.
The module can monitor compatible dry contacts and operate relay-based auxiliary circuits. Motor power switching should use appropriately rated contactors and protective equipment rather than relying on the module’s small relay contacts for direct motor switching.
Some building and utility systems require a combination of discrete status monitoring and relay-based switching.
The module may be used to collect equipment status signals and control compatible auxiliary devices within a properly designed VersaMax automation system.
Process machinery often requires the collection of binary status signals from valves, switches, and auxiliary equipment. The module can support these functions when its voltage and contact ratings match the field devices.
It is not a substitute for dedicated safety-rated I/O in applications requiring certified safety functions.
Correct installation is essential for reliable operation and protection of the module and connected equipment.
The IC200MDD845G requires a compatible VersaMax carrier base. Confirm the carrier model and its mechanical and electrical compatibility before installation.
The module should be seated correctly and secured according to the manufacturer’s installation instructions.
The input section is designed for 24 V DC signals. Verify the signal voltage, polarity, common wiring, and field-device output type before connecting the input terminals.
Incorrect wiring may result in unreliable signal detection or damage to connected equipment.
The eight relay outputs are Form A contacts. Each output must be wired according to the connected load’s voltage and current requirements.
Observe the specified contact ratings:
These are maximum ratings under defined conditions, not universal ratings for every load type.
The module’s backplane supplies power for its internal operation. External power must be provided for the loads connected through the relay contacts.
The external supply should be appropriately rated and protected. Do not assume that the module’s backplane power can directly supply connected field loads.
Relay contacts switching inductive loads may experience electrical arcing and contact stress.
Since the module does not include internal fuses or snubbers, suitable external suppression and protective devices may be required. Select these components according to the load characteristics and applicable electrical standards.
After physical installation, configure the module in the VersaMax controller or network interface system.
Verify the input and output point assignments, addressing, configuration parameters, and controller recognition. Test each input and output point before placing the machine into normal operation.
Commissioning should include:
Document the final I/O assignments and wiring details for future maintenance.
The IC200MDD845G operates as part of a VersaMax I/O system. The following components may be relevant to a complete installation.
| Component | Function | Compatibility Considerations |
|---|---|---|
| VersaMax carrier base | Provides the mechanical and electrical interface | Use a compatible IC200CHS-series carrier |
| VersaMax CPU | Executes PLC control logic | Verify the controller’s supported I/O configuration |
| Network Interface Unit | Connects distributed I/O to the control network | Confirm system architecture and supported module configuration |
| 24 V DC power supply | Supplies field input devices and control circuits | Check current capacity and grounding |
| Digital input devices | Provide binary field signals | Verify 24 V DC signal compatibility |
| Interposing relays | Interface relay outputs with external circuits | Select coil voltage and contact ratings appropriately |
| Contactors | Switch motor or larger power circuits | Use the module to control suitable contactor coils, not as a replacement for power switching equipment |
| Indicator lamps | Display machine and process states | Check the lamp voltage and current |
| Protective devices | Protect external wiring and loads | Select fuses and suppression devices for the application |
The table describes typical system components. They are not necessarily supplied with the IC200MDD845G.
The IC200MDD845G belongs to the VersaMax discrete mixed I/O family. Related models may offer different combinations of input voltage, output type, and channel count.
| Model | General Function | Main Difference |
|---|---|---|
| IC200MDD844 | Mixed discrete I/O module | 16 inputs and 16 transistor outputs |
| IC200MDD845 | Mixed discrete I/O module | 16 inputs and 8 isolated relay outputs |
| IC200MDD846 | Mixed discrete I/O module | 8 AC inputs and 8 isolated relay outputs |
| IC200MDD847 | Mixed discrete I/O module | 8 AC input channels with relay outputs |
| IC200MDD848 | Mixed discrete I/O module | Different AC input and output configuration |
These are related family models, not guaranteed drop-in replacements.
Before choosing a replacement, compare:
A replacement with the same number of channels may still have a different electrical interface. Confirm the complete catalog number and hardware revision before installation.
The module combines 16 digital inputs and 8 relay outputs in one assembly, supporting applications that require both signal acquisition and external circuit switching.
The eight Form A relay outputs provide individual channel isolation, helping accommodate separate external circuits within the specified electrical limits.
The relay contacts can switch compatible AC and DC loads within their rated voltage and current ranges.
The module is designed for installation in a VersaMax carrier-based I/O system, supporting organized control-panel layouts.
Individual LEDs help technicians identify the logical state of input and output points during troubleshooting.
The module provides discrete field signals to a compatible VersaMax controller or network interface unit, allowing input conditions and output commands to be coordinated through PLC logic.
It is a GE Fanuc VersaMax discrete mixed I/O module that combines 16 digital input channels with 8 relay output channels.
It provides 24 points in total: 16 inputs and 8 outputs.
The input section is designed for nominal 24 V DC signals, with an operating range specified in the module documentation.
It provides eight individually isolated Form A relay outputs.
The specified maximum is 2.0 A for supported AC and low-voltage DC resistive loads. For the specified 31–125 V DC range, the maximum is 0.2 A. Always follow the detailed load and voltage ratings.
The module receives its internal operating power from the VersaMax backplane. However, external power is required for the loads switched by the relay contacts.
Relay outputs can be used in appropriately designed circuits, but inductive loads require careful consideration. External suppression and protection may be necessary because the module does not include internal fuses or snubbers.
Yes. The module is designed for use with a compatible VersaMax carrier base.
Check the OK LED, individual input and output LEDs, carrier connection, field wiring, external supply, and PLC I/O configuration. For relay outputs, verify the contact operation and external load circuit separately.
Not directly without reviewing the application. The IC200MDD845 uses relay outputs, while the IC200MDD844 has a different output configuration. The output technology, wiring, load requirements, and controller configuration must be checked.
When sourcing the GE IC200MDD845G, verify the complete catalog number and hardware revision. The IC200MDD845 family includes different revision identifiers, and the correct revision may be important for input logic behavior, system compatibility, and replacement planning.
For used or surplus modules, inspect the terminal connections, housing, carrier interface, and status indicators. Request clear photographs of the product label and ask for functional test information where available.
Before installation, confirm the carrier base, controller compatibility, 24 V DC input wiring, relay output ratings, and external load protection. Do not assume that the module can switch a load simply because its nominal current is below the relay’s maximum rating; voltage, load type, switching frequency, and electrical life must also be considered.
During routine maintenance, inspect wiring terminals and external loads, monitor the module’s status indicators, and check relay operation if a controlled device fails to respond. Keep an updated record of I/O addresses, terminal assignments, and the connected field devices.
The GE IC200MDD845G VersaMax Discrete Mixed I/O Module combines 16 digital input channels with 8 individually isolated Form A relay outputs. Designed for the GE Fanuc VersaMax automation platform, it provides a compact interface for collecting 24 V DC field signals and switching compatible external circuits.
Its mixed I/O arrangement can simplify machine-control installations that require both signal monitoring and relay-based control. For successful operation, engineers should verify carrier-base compatibility, input wiring, relay contact ratings, external load protection, and PLC configuration.
For replacement and maintenance projects, checking the complete model and hardware revision is essential to ensure that the module matches the original system’s electrical and functional requirements.