The Honeywell 2MLQ-TR4A is a 32-point transistor output module for the MasterLogic-200 PLC system. It uses a sinking (NPN) output configuration to switch DC loads connected to the controller, making it suitable for applications involving solenoid valves, indicator lamps, relay coils, and other low-current control devices.
Unlike relay output modules, which use mechanical contacts, the 2MLQ-TR4A uses semiconductor switching. This allows it to handle frequent switching operations without mechanical contact wear. Its relatively short response time is useful in automated machinery where output commands need to follow PLC logic with minimal delay.
Each output point supports a maximum load current of 0.1 A, while each common terminal supports a maximum combined current of 2 A. The module provides 32 output points arranged around a common connection, allowing multiple field devices to be controlled from one PLC module position.
A typical application would be a packaging machine with several pneumatic valves, machine-status indicators, and auxiliary control circuits. The PLC can use the 2MLQ-TR4A to switch these devices according to sensor feedback and programmed machine sequences.
The sinking output arrangement is an important selection consideration. Connected loads must be wired with the appropriate positive supply and output-side connections. A source-type module such as the 2MLQ-TR4B has a different electrical configuration and should not be treated as a direct substitute.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model | 2MLQ-TR4A |
| Product Type | 32-Point Transistor Output Module |
| Product Series | MasterLogic-200 |
| Output Type | Transistor Output (Sink Type) |
| Output Points | 32 |
| Isolation Method | Photo Coupler Isolation |
| Rated Load Voltage | DC 12/24 V |
| Load Voltage Range | DC 10.2–26.4 V |
| Maximum Load Current | 0.1 A/Point, 2 A/COM |
| Off-State Leakage Current | 0.1 mA or less |
| Maximum Inrush Current | 0.7 A / 10 ms or less |
| Maximum ON-State Voltage Drop | DC 0.2 V or less |
| Surge Absorber | Zener Diode |
| OFF-to-ON Response Time | 1 ms or less |
| ON-to-OFF Response Time | 1 ms or less |
| Common Configuration | 32 Points / 1 COM |
| Current Consumption | 130 mA (all points ON) |
| External Power Supply | DC 12/24 V ±10% |
| External Power Supply Current | 10 mA or less (DC 24 V connection) |
| Operation Indicator | Output ON LED |
| External Connection | 40-Pin Connector |
| Recommended Cable Size | 0.3 mm² |
| Dimensions | 114 × 48 × 127 mm |
| Weight | 0.1 kg |
1. 32-Point Transistor Output
The module provides 32 independent digital output points for controlling external DC devices. This channel density is useful in machinery with numerous small actuators, indicator circuits, and auxiliary control signals.
2. Sinking Output Configuration
The 2MLQ-TR4A uses a sinking transistor output arrangement. When an output switches ON, the corresponding load circuit is connected toward the common return path. The external load wiring must follow the sinking-output configuration.
3. DC 12/24 V Load Compatibility
The module supports rated load voltages of DC 12 V and DC 24 V, with an allowable load voltage range of DC 10.2–26.4 V. This makes it suitable for common industrial DC control circuits.
4. Photo Coupler Isolation
Photo coupler isolation separates the output signal circuitry from the internal control electronics. This provides electrical isolation between the PLC-side control circuitry and the external output circuits.
5. Fast Switching Response
Both OFF-to-ON and ON-to-OFF response times are specified at 1 ms or less. This is useful for repetitive machine sequences and applications requiring relatively rapid digital output updates.
6. Individual and Common Current Limits
Each output point supports up to 0.1 A, while the common connection supports a maximum of 2 A. Both limits must be considered when assigning loads, especially when multiple outputs operate simultaneously.
7. Integrated Surge Absorption
A Zener diode surge absorber helps suppress voltage transients associated with switching inductive loads. External load protection should still be selected according to the connected device and its electrical characteristics.
8. LED Output Indication
The module provides an output ON LED indication. Maintenance personnel can use the indicator to check switching activity during commissioning and troubleshooting.
9. 40-Pin External Connection
The module uses a 40-pin connector for external wiring. An appropriate connector cable or interface assembly is required to connect the output points to the field wiring arrangement.
The 2MLQ-TR4A receives output commands from the MasterLogic-200 CPU and converts them into transistor switching signals for external DC loads.
Its sinking output arrangement means that the module switches the load circuit toward the common return when the corresponding output point is activated. The external load is typically connected between the positive DC supply and the module’s output terminal.
When the PLC program activates an output, the corresponding transistor conducts and completes the load circuit. When the output command is removed, the transistor switches OFF and interrupts the current path.
The module uses photo coupler isolation between the internal control circuitry and output circuitry. This separates the PLC control signals from the external load-side electrical circuit.
Typical Output Switching Sequence:
Example: Pneumatic Valve Control
In an automated assembly machine, a PLC may control several pneumatic solenoid valves through the 2MLQ-TR4A. When a sensor confirms that a workpiece is correctly positioned, the PLC activates the assigned output. The corresponding transistor switches the solenoid circuit, energizing the valve coil and initiating the pneumatic movement.
After the programmed operation is completed, the CPU removes the output command and the transistor switches OFF. This sequence can be repeated across multiple stations using the module’s available output points.
Within the MasterLogic-200 PLC system, the 2MLQ-TR4A functions as the digital output interface between the controller and external DC field devices.
The CPU executes the application program and determines the required output states. The 2MLQ-TR4A then performs the physical switching operations based on those commands.
Its 32-point configuration is particularly useful when several low-current devices need to be controlled from one output module. Instead of installing numerous individual relay interfaces, an automation system can use the transistor outputs for compatible DC switching applications.
The module belongs to the MasterLogic-200 digital output family, which also includes relay, source-type transistor, and other transistor output configurations.
| Control System Component | Function |
|---|---|
| 2MLQ-TR4A | 32-point sinking transistor output |
| 2MLQ-TR4B | 32-point sourcing transistor output |
| 2MLQ-TR2A | 16-point sinking transistor output |
| 2MLQ-TR2B | 16-point sourcing transistor output |
| 2MLQ-TR8A | 64-point sinking transistor output |
| 2MLQ-TR8B | 64-point sourcing transistor output |
| 2MLQ-RY1A | 8-point relay output |
| 2MLQ-RY2A | 16-point relay output |
| 2MLQ-RY2B | 16-point relay output with varistor |
| 2MLI-D24B | 32-point digital input module |
| 2MLI-D28B | 64-point digital input module |
| 2MLI-CPUH | High Performance IEC CPU |
| 2MLI-CPUS | Standard IEC CPU |
| 2MLP-ACF1 | Power Supply Module |
| 2MLP-DC42 | DC Input Power Supply Module |
| 2MLB-M06A | Main CPU Base |
| 2MLB-E08A | Expansion I/O Base |
| Application | Output Control Function |
|---|---|
| Packaging Machinery | Controls pneumatic valves, indicators, and auxiliary DC devices |
| Automated Assembly Lines | Switches actuators and machine sequence control signals |
| Conveyor Systems | Controls DC interface circuits and equipment status indicators |
| Material Handling | Operates compatible low-current control devices |
| Automotive Manufacturing | Handles distributed machine output signals |
| Pneumatic Control Systems | Switches compatible DC solenoid valve circuits |
| Machine Tool Automation | Controls auxiliary machine functions and interlocks |
| Industrial Sorting Equipment | Activates pneumatic diverters and indicator circuits |
| Automated Inspection Systems | Controls external DC devices according to inspection results |
| Component | Product Type | Application |
|---|---|---|
| 2MLQ-TR4B | 32-Point Transistor Output Module (Source) | Alternative sourcing output configuration |
| 2MLQ-TR2A | 16-Point Transistor Output Module (Sink) | Lower-density sinking output applications |
| 2MLQ-TR2B | 16-Point Transistor Output Module (Source) | Lower-density sourcing output applications |
| 2MLQ-TR8A | 64-Point Transistor Output Module (Sink) | Higher-density sinking output applications |
| 2MLQ-TR8B | 64-Point Transistor Output Module (Source) | Higher-density sourcing output applications |
| 2MLQ-RY1A | Relay Output Module | Switching applications requiring relay contacts |
| 2MLQ-RY2A | Relay Output Module | 16-point relay switching |
| 2MLQ-RY2B | Relay Output Module with Varistor | Relay output with integrated surge suppression |
| 2MLI-D24B | Digital Input Module | Receives 32 digital field signals |
| 2MLI-D28B | Digital Input Module | Receives 64 digital field signals |
| 2MLI-CPUH | High Performance CPU Module | Executes PLC application logic |
| 2MLI-CPUS | Standard CPU Module | Standard PLC processing |
| 2MLP-ACF1 | AC Power Supply Module | Supplies PLC operating power |
| 2MLP-DC42 | DC Power Supply Module | Supplies PLC operating power |
| 2MLB-M06A | Main CPU Base | Houses CPU and associated modules |
| 2MLB-E08A | Expansion I/O Base | Supports additional I/O modules |
| Model | Product Description |
|---|---|
| 2MLQ-TR4B | MasterLogic-200 32-Point Transistor Output Module (Source Type) |
| 2MLQ-TR2A | MasterLogic-200 16-Point Transistor Output Module (Sink Type) |
| 2MLQ-TR2B | MasterLogic-200 16-Point Transistor Output Module (Source Type) |
| 2MLQ-TR8A | MasterLogic-200 64-Point Transistor Output Module (Sink Type) |
| 2MLQ-RY2A | MasterLogic-200 16-Point Relay Output Module |
| 2MLQ-RY2B | MasterLogic-200 16-Point Relay Output Module with Varistor |
Both modules provide 32 transistor output points, but their output configurations differ. The 2MLQ-TR4A uses sinking (NPN) outputs, while the 2MLQ-TR4B uses sourcing (PNP) outputs. The correct model depends on the external load wiring and control circuit design.
It can control a compatible 24 V DC solenoid valve provided that the coil current does not exceed 0.1 A per output and the common-group current remains within 2 A. The coil’s inrush and inductive characteristics should also be checked before connecting it.
The module supports a maximum of 0.1 A per point and 2 A per COM. These are separate limits. Even when every individual load is below 0.1 A, the combined current of the common group must not exceed 2 A.
Transistor outputs provide semiconductor switching without mechanical contacts. This makes them suitable for frequent switching of compatible DC loads and applications requiring short response times. However, they are not a universal replacement for relay outputs, particularly where AC loads or higher switching currents are involved.