• Schneider MVS10H Circuit Breaker
  • Schneider MVS10H Circuit Breaker
  • Schneider MVS10H Circuit Breaker
  • Schneider MVS10H Circuit Breaker
Product Overview The Schneider Electric MVS10H EasyPact Circuit Breaker is a low-voltage air circuit breaker (ACB) designed for electrical power distribution and protection in industrial and commercial ……
Schneider MVS10H Circuit Breaker
  • Schneider
  • MVS10H
  • Circuit Breaker
  • France
  • 352 x 422 x 297 mm
  • 40 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider MVS10H Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MVS10H Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MVS10H Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MVS10H Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MVS10H EasyPact Circuit Breaker is a low-voltage air circuit breaker (ACB) designed for electrical power distribution and protection in industrial and commercial installations. As part of the EasyPact MVS product family, it is intended to protect electrical distribution systems against overloads and short-circuit faults while supporting reliable power management in switchboards and distribution panels.

Air circuit breakers are commonly installed in main distribution boards, power control centers, industrial substations, and large electrical switchboards. They provide a means of controlling and isolating electrical circuits while protecting downstream equipment from abnormal current conditions.

The MVS10H family includes configurations with a rated current of 1000 A, three-pole construction, and a high breaking-capacity classification. Depending on the complete catalog number, the breaker may be equipped with different electronic trip units, operating mechanisms, and mounting arrangements.

A representative fixed-mounted MVS10H configuration provides a rated operational voltage of up to 690 V AC at 50/60 Hz and a rated ultimate short-circuit breaking capacity of 65 kA at 220–440 V AC. These characteristics make the product family suitable for demanding low-voltage distribution applications when correctly selected for the installation.

The MVS10H is not a complete ordering reference by itself. The full catalog number is necessary to identify the exact trip unit, protection functions, installation type, and operating mechanism. Buyers and maintenance engineers should therefore verify the complete model before ordering a replacement.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series EasyPact MVS
Product Family MVS10H
Product Type Air Circuit Breaker (ACB)
Application Electrical Power Distribution
Rated Current 1000 A for representative MVS10H configurations
Number of Poles 3P
Rated Operational Voltage Up to 690 V AC
Rated Frequency 50/60 Hz
Breaking Capacity Class H
Ultimate Breaking Capacity (Icu) 65 kA at 220–440 V AC
Rated Insulation Voltage 1000 V AC
Impulse Withstand Voltage 12 kV
Trip Unit Depends on complete catalog number
Trip Technology Electronic for representative configurations
Mounting Type Depends on configuration; fixed or drawout versions exist
Operating Mechanism Manual or electrical, depending on configuration
Dimensions Provided 352 × 422 × 297 mm
Weight Provided 40 kg
Typical Installation Low-voltage distribution switchboards

Important: MVS10H identifies a product family rather than one complete configuration. The technical details above describe representative 1000 A fixed-mounted versions. Confirm the complete catalog number and nameplate before using these values for equipment selection or replacement.

Function and Working Principle

The MVS10H air circuit breaker provides electrical protection by monitoring current conditions and interrupting the circuit when a fault exceeds the configured protection limits.

Its operating functions involve current sensing, electronic protection logic, mechanical switching, and arc interruption.

1. Overload Protection

An overload occurs when electrical equipment draws more current than the circuit is designed to carry for an extended period.

The electronic trip unit monitors the current flowing through the breaker. When the current exceeds the configured long-time protection threshold, the trip unit initiates a protective trip after the specified delay.

This function helps prevent excessive heating in conductors, busbars, transformers, and connected electrical equipment.

2. Short-Circuit Protection

A short circuit can cause a sudden and substantial increase in current. If not interrupted quickly, the resulting electrical and thermal energy can damage switchgear and connected equipment.

The MVS10H family includes configurations with short-time and instantaneous protection functions. The exact protection functions depend on the installed electronic trip unit.

When a fault is detected, the trip mechanism opens the main contacts and interrupts the electrical circuit.

3. Electronic Trip Unit Operation

Depending on the complete model reference, the MVS10H can be supplied with different electronic trip units, such as ET2, ET5, or ET6 configurations.

These units provide different protection capabilities.

Common protection functions include:

  • Long-time protection for overload conditions.
  • Short-time protection for delayed short-circuit interruption.
  • Instantaneous protection for severe short-circuit conditions.
  • Ground-fault protection on suitable trip-unit versions.

The adjustment ranges and available protection functions must be confirmed from the exact trip-unit specification.

4. Arc Interruption

When the breaker opens under load or fault conditions, an electrical arc can form between the separating contacts.

An air circuit breaker uses an arc-extinguishing arrangement to control and interrupt this arc. The interruption process helps isolate the faulty circuit and protect the electrical distribution system.

The breaker must be selected according to the installation voltage and prospective short-circuit current to ensure that its interrupting capability is adequate.

5. Electrical Isolation

The MVS10H family is designed for use in electrical distribution systems where circuit control and isolation are required.

When correctly installed and operated, the breaker can isolate the protected circuit for maintenance or fault management. Electrical isolation procedures must still follow the applicable safety regulations and site lockout requirements.

Role in Industrial Power Distribution Systems

The Schneider Electric MVS10H plays an important role in low-voltage power distribution installations. It is generally used as a main or feeder circuit breaker in switchboards that supply multiple downstream electrical circuits.

Main Incoming Circuit Protection

In a main distribution panel, an air circuit breaker can serve as the incoming protective device between the transformer or upstream power source and the distribution busbar system.

It helps protect the downstream electrical network against overload and short-circuit conditions.

Feeder Circuit Protection

Industrial distribution systems often contain multiple feeders supplying motors, production lines, lighting systems, auxiliary equipment, and other electrical loads.

The MVS10H family can be used in suitable feeder applications where its rated current and breaking capacity match the system requirements.

Coordination with Downstream Protection

Electrical protection coordination helps ensure that the protective device closest to a fault operates when appropriate, limiting unnecessary interruption to other parts of the installation.

The breaker’s adjustable electronic protection settings can support coordination studies when the selected trip unit provides the required functions.

Integration with Electrical Monitoring Systems

Depending on the installed accessories and trip-unit configuration, an air circuit breaker may be incorporated into a broader electrical monitoring and control arrangement.

Possible functions include status indication, remote operation, and electrical measurement. These capabilities depend on the actual accessories and control components installed and should not be assumed from the MVS10H family designation alone.

Industrial Applications

The MVS10H EasyPact circuit breaker family is intended for low-voltage electrical distribution systems in industrial and commercial environments.

1. Industrial Manufacturing Plants

Manufacturing facilities require stable electrical distribution for production machinery, control panels, motors, and auxiliary equipment.

An appropriately rated MVS10H breaker can serve as a main or feeder protective device in a distribution board, helping isolate electrical faults and protect downstream circuits.

2. Power Distribution Switchboards

Low-voltage switchboards distribute electrical power to different sections of a facility.

The MVS10H can be installed in suitable switchboard configurations to provide circuit protection and switching functions for high-current distribution circuits.

3. Commercial Buildings

Large commercial buildings may contain electrical distribution systems supplying HVAC equipment, elevators, lighting, pumps, and other building services.

A correctly selected air circuit breaker can provide protection for major incoming or outgoing distribution circuits.

4. Data Centers

Data centers require carefully engineered electrical distribution systems to support servers, cooling systems, UPS equipment, and auxiliary infrastructure.

Air circuit breakers may be used in main distribution and feeder arrangements where their electrical ratings and protection characteristics match the system design.

Protection coordination and continuity-of-service requirements are particularly important in these installations.

5. Infrastructure and Utility Facilities

Infrastructure facilities such as transportation centers, water treatment plants, and industrial utility stations rely on dependable low-voltage distribution.

The MVS10H family may be considered for suitable applications where its rated current, voltage, and fault-interruption capabilities meet the installation requirements.

Installation and System Integration

Correct installation is essential for the safe and reliable operation of an air circuit breaker.

1. Verify the Complete Model Number

Before installation, identify the full catalog number rather than relying only on the MVS10H family designation.

Different versions may have different trip units, mounting arrangements, operating mechanisms, and accessories.

Confirm the rated current, voltage, breaking capacity, and protection functions from the actual nameplate and product documentation.

2. Check Electrical System Compatibility

Verify that the circuit breaker’s rated operational voltage is suitable for the distribution system.

The prospective short-circuit current at the installation point must not exceed the breaker’s applicable interrupting rating.

Engineers should also evaluate the system’s grounding arrangement, conductor ratings, busbar capacity, and upstream and downstream protective devices.

3. Mechanical Installation

The supplied dimensions are 352 × 422 × 297 mm, and the listed weight is 40 kg.

Confirm the dimensions against the exact fixed-mounted configuration and manufacturer drawings before designing the switchboard.

Because the breaker is a relatively heavy electrical component, suitable lifting equipment and approved installation procedures should be used.

The mounting structure must provide sufficient mechanical strength and maintain the required clearances.

4. Electrical Connections

The MVS10H family supports rear electrical connections in suitable configurations, with horizontal or vertical connection arrangements depending on the model.

Connection orientation, terminal accessories, conductor sizing, and tightening requirements must be checked against the applicable installation instructions.

Poor electrical connections can cause overheating, increased contact resistance, and equipment damage.

5. Protection Setting Configuration

The electronic trip unit must be configured according to the electrical protection study.

Important settings may include:

  • Long-time current pickup.
  • Long-time delay.
  • Short-time current pickup.
  • Short-time delay.
  • Instantaneous current pickup.
  • Ground-fault pickup and delay, where supported.

Protection settings should be established by qualified electrical engineers based on the installation’s load characteristics and fault-current calculations.

6. Testing and Commissioning

Before energizing the system, inspect the mechanical installation, electrical connections, grounding, and accessory wiring.

Commissioning should include appropriate operational checks and verification of the trip-unit settings.

For critical installations, protection testing should be carried out using suitable test equipment and procedures specified by the manufacturer and applicable standards.

Compatible System Components

The MVS10H air circuit breaker is generally installed as part of a larger low-voltage electrical distribution system.

Component Function Integration Considerations
Low-voltage switchboard Houses the breaker and distributes electrical power Verify mounting space, busbar ratings, and clearances
Electrical busbars Carry current between distribution components Confirm current rating and short-circuit withstand capacity
Electronic trip unit Monitors current and initiates protective tripping Select according to required protection functions
Auxiliary contacts Provide breaker status signals Confirm contact arrangement and electrical ratings
Shunt trip accessory Enables remote electrical tripping Verify accessory compatibility and control voltage
Undervoltage release Trips or prevents closing under specified voltage conditions Check the exact accessory configuration
Motorized operating mechanism Enables electrical operation where supported Confirm the breaker version and accessory requirements
Current transformers or sensors Provide current information for protection functions Verify compatibility with the installed trip unit
PLC or monitoring system Monitors breaker status and coordinates plant operation Additional communication or signaling accessories may be required

Not every component is included with the standard breaker. Accessory compatibility must be confirmed using the complete catalog number.

Alternative Models and Replacement Considerations

The EasyPact MVS family includes different current ratings, breaking capacities, trip-unit configurations, and installation arrangements.

When replacing an MVS10H, engineers should compare the complete product reference rather than selecting another breaker based only on its frame designation.

Alternative or Related Option Replacement Considerations
Schneider EasyPact MVS10H fixed version Suitable for evaluation when the original fixed mounting and electrical ratings match
Schneider EasyPact MVS10H drawout version Requires compatible chassis, dimensions, and connection arrangements
Schneider EasyPact MVS12H Higher current-frame family; verify electrical ratings and installation requirements
Schneider EasyPact MVS16H Higher-rated family for applications requiring a different current capacity
Schneider MasterPact series May be considered for system upgrades, subject to detailed engineering evaluation

Before selecting a replacement, compare:

  • Rated current and voltage.
  • Number of poles.
  • Ultimate and service breaking capacity.
  • Trip-unit type and protection functions.
  • Fixed or drawout installation.
  • Manual or electrical operating mechanism.
  • Terminal and busbar connection arrangements.
  • Auxiliary contacts and other accessories.
  • Switchboard dimensions and mounting requirements.
  • Protection coordination with upstream and downstream devices.

A replacement breaker must meet the electrical and mechanical requirements of the installation. A similar product name does not guarantee direct interchangeability.

Key Advantages

High-Current Distribution Capability

Representative MVS10H configurations support a rated current of 1000 A, making the product family suitable for selected high-current low-voltage distribution applications.

Short-Circuit Protection

The H-class configuration provides a high short-circuit breaking capability, including a published Icu rating of 65 kA at 220–440 V AC for representative versions.

Electronic Protection

Depending on the installed trip unit, the breaker can provide adjustable electronic protection functions for overload and short-circuit conditions.

Industrial Switchboard Integration

The MVS10H family is designed for integration into industrial and commercial low-voltage distribution assemblies.

Flexible Configuration Options

Different versions offer alternative trip units, mounting methods, and operating mechanisms, allowing the equipment to be selected according to system requirements.

Maintenance and Monitoring Options

Suitable accessories can support status indication, remote operation, and integration with electrical monitoring arrangements.

Technical FAQs

1. What is the Schneider MVS10H?

The MVS10H is part of Schneider Electric’s EasyPact MVS air circuit breaker family. It is designed for low-voltage electrical distribution and circuit protection.

2. What is the rated current of the MVS10H?

Representative MVS10H configurations have a rated current of 1000 A at 40 °C. The exact rating should be confirmed from the complete model number and nameplate.

3. What is the maximum operating voltage?

Representative MVS10H configurations have a rated operational voltage of up to 690 V AC at 50/60 Hz.

4. What is the breaking capacity of the MVS10H?

The H-class version has a published ultimate breaking capacity of 65 kA at 220–440 V AC. The applicable breaking capacity varies with operating voltage and the exact configuration.

5. Is the MVS10H a fixed or drawout circuit breaker?

Both fixed and drawout configurations exist within the MVS10H family. The complete catalog number is required to identify the mounting arrangement.

6. Does the MVS10H provide electronic protection?

Yes, representative configurations use electronic trip units. Available protection functions depend on whether the breaker is equipped with an ET2, ET5, ET6, or another specified trip-unit version.

7. Can the MVS10H be integrated with a PLC?

The breaker can be incorporated into an industrial monitoring or control system using compatible auxiliary contacts and optional accessories. Communication capabilities depend on the installed hardware and should be verified separately.

8. What are the dimensions of the MVS10H?

The supplied dimensions are 352 × 422 × 297 mm. These correspond to a representative fixed-mounted configuration. Confirm the exact dimensions before switchboard installation.

9. What is the weight of the MVS10H?

The supplied product weight is 40 kg. Actual weight should be confirmed against the exact configuration and packaging arrangement.

10. What information is required when purchasing a replacement?

The complete catalog number, rated current, voltage, breaking capacity, trip-unit type, mounting arrangement, operating mechanism, and accessory configuration should all be checked before ordering.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric MVS10H, buyers should first identify the complete product reference. The MVS10H family designation alone does not provide enough information to establish the exact breaker configuration.

For replacement projects, compare the nameplate and trip-unit details of the existing breaker with the proposed replacement. Pay particular attention to the rated current, voltage, breaking capacity, mounting arrangement, and protection functions.

For used or refurbished equipment, request clear photographs of the nameplate, front panel, terminals, and operating mechanism. Check the condition of the contacts, insulation components, mechanical linkages, and trip unit. Where possible, obtain evidence of functional testing and confirm the supplier’s warranty and return conditions.

Routine maintenance should follow the manufacturer’s instructions and the facility’s electrical maintenance program. Inspections may include checking terminal connections, mechanical operation, contact condition, accessory wiring, and trip-unit settings.

Protection settings should be documented and reviewed whenever the electrical distribution system changes. Any replacement or modification must be evaluated by qualified personnel to ensure that the breaker remains suitable for the system’s fault levels and coordination requirements.

Conclusion

The Schneider Electric MVS10H EasyPact air circuit breaker is designed for low-voltage power distribution and protection in industrial and commercial electrical systems. Representative 1000 A configurations provide three-pole operation, a rated operational voltage of up to 690 V AC, and an H-class short-circuit breaking capacity of 65 kA at 220–440 V AC.

With electronic protection options and different mounting configurations available across the product family, the MVS10H can be incorporated into appropriately engineered distribution switchboards.

For procurement, maintenance, and replacement applications, confirming the complete catalog number is essential. Correct identification of the trip unit, mounting arrangement, operating mechanism, and accessories helps ensure electrical compatibility and reliable operation.