Product Overview The Foxboro RH917JJ is an I/A Series module fieldbus cable used to connect compatible Foxboro baseplates in a distributed control system. It is associated with the earlier P0917JJ refer……
Foxboro RH917JJ I/A Series Base-to-Base Data Cable
  • Foxboro
  • RH917JJ
  • Base-to-Base Data Cable
  • USA
  • 0.5 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Foxboro RH917JJ I/A Series Base-to-Base Data Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro RH917JJ I/A Series Base-to-Base Data Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro RH917JJ I/A Series Base-to-Base Data Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro RH917JJ I/A Series Base-to-Base Data Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro RH917JJ is an I/A Series module fieldbus cable used to connect compatible Foxboro baseplates in a distributed control system. It is associated with the earlier P0917JJ reference and is intended for a 2 Mbps base-to-base communication connection. With a specified cable length of 0.5 meters, it suits installations where adjacent baseplates need a short, direct communication link. <Cite refs={[“turn390169search0″,”turn390169search3”]}/>

In an industrial control cabinet, baseplates provide mounting and electrical interfaces for fieldbus modules and related hardware. The RH917JJ carries communication signals between designated baseplate connections, allowing the connected equipment to exchange data through the established fieldbus arrangement.

The cable is particularly relevant when maintaining legacy I/A Series systems in which the original baseplate layout must be preserved. During module replacement, cabinet refurbishment, or communication troubleshooting, using the appropriate cable reference helps maintain the intended connection between compatible hardware. The cable can also support bus redundancy in applicable baseplate configurations, depending on the installed system topology.

The RH917JJ is a passive cable assembly rather than an active communication device. It does not process messages, regenerate signals, or execute control logic. Correct operation depends on compatible baseplates, secure connectors, appropriate cable routing, and the required fieldbus termination arrangement.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Model RH917JJ
Associated Legacy Reference P0917JJ
Product Family I/A Series
Product Type Base-to-Base Data Cable
Cable Application Module fieldbus communication
Communication Rate 2 Mbps
Cable Length 0.5 meters
Connection Type Baseplate-to-baseplate
Operating Function Electrical data transmission
System Application Compatible Foxboro I/A Series baseplates
Shipping Weight 3 kg

Product Features

  • 2 Mbps fieldbus communication: Supports the specified data connection between compatible baseplates.
  • 0.5-meter cable length: Accommodates short interconnections in compact control-cabinet layouts.
  • Base-to-base connection: Provides the physical signal path between designated module fieldbus interfaces.
  • Redundancy support: Can be used in supported arrangements where the baseplate communication design requires a redundant connection.
  • Passive cable assembly: Carries electrical signals without independent data processing.
  • Legacy system maintenance: Supports replacement of the associated P0917JJ cable reference when compatibility is verified.

Working Principle

The RH917JJ provides a conductive path for module fieldbus signals between compatible baseplates. When the connected I/A Series hardware exchanges data, the cable carries the electrical signals required for communication.

Baseplate A → RH917JJ Data Cable → Baseplate B

The cable does not determine message timing or interpret data. Those functions are handled by the connected control-system hardware. The cable’s role is to preserve the physical connection required by the configured fieldbus architecture.

On compatible baseplates, the module fieldbus connectors may be internally connected in parallel, allowing the designated connectors to be used for supported base-to-base connections. The actual arrangement must follow the applicable system documentation, particularly where redundant connections or bus termination are involved.

If communication becomes intermittent, inspect the cable jacket, connector contacts, and seating at both ends. Also check the baseplate configuration and termination arrangement. A physically compatible connector does not guarantee that an alternative cable has the correct wiring or electrical characteristics.


Role in the Foxboro I/A Series Fieldbus Architecture

The RH917JJ provides the physical communication link between compatible baseplates. The connected hardware performs fieldbus processing and control-system operations, while the cable carries the signals between the interfaces.

I/A Series Baseplate A → RH917JJ → I/A Series Baseplate B → Connected Fieldbus Modules

System Element Function
RH917JJ Carries fieldbus signals between compatible baseplates
Modular Baseplate Provides mounting and fieldbus connection interfaces
Fieldbus Module (FBM) Performs assigned process input and output functions
Control Processor Executes control logic and coordinates system operation
Fieldbus Terminator Terminates the communication bus where required
Redundant Connection Provides an additional communication path in supported configurations
Cabinet Wiring Maintains the intended routing of communication and power connections

Industrial Applications

Application Practical Use
Foxboro I/A Series DCS Cabinets Connecting compatible baseplates within an established system layout
Process Automation Plants Maintaining fieldbus links between control-system bases
Chemical Processing Facilities Supporting communication between installed automation hardware
Oil and Gas Installations Maintaining designated base-to-base connections
Power Generation Plants Replacing communication cables during scheduled maintenance
Water and Wastewater Systems Supporting compatible distributed control equipment
Legacy Control-System Maintenance Retaining existing baseplate communication arrangements
Control Cabinet Refurbishment Replacing damaged cables without redesigning the cabinet
DCS Expansion Projects Connecting additional compatible baseplates
Communication Fault Diagnosis Checking physical cable connections when fieldbus communication is interrupted

Installation and Maintenance

  1. Verify the complete part number: Confirm RH917JJ and check its association with the installed P0917JJ cable configuration.
  2. Identify both endpoints: Determine which baseplates and fieldbus interfaces the cable must connect.
  3. Confirm baseplate compatibility: Check that the connected hardware supports the required 2 Mbps fieldbus connection.
  4. Follow the maintenance procedure: Apply the prescribed system isolation and communication-maintenance procedures before disconnecting the cable.
  5. Inspect the cable jacket: Look for cuts, crushing, deformation, or other mechanical damage.
  6. Examine the connectors: Check for bent contacts, contamination, corrosion, and damaged retaining features.
  7. Maintain suitable routing: Avoid sharp bends, excessive tension, and contact with sharp cabinet edges.
  8. Check the connection topology: Confirm that the cable is used in the intended base-to-base arrangement and that any redundancy requirements are satisfied.
  9. Verify bus termination: Check that the required terminators are installed according to the baseplate configuration and system design.
  10. Reconnect both ends: Seat the connectors fully and secure them according to the applicable installation requirements.
  11. Test the fieldbus link: Check system status indications and verify normal communication after reconnection.
  12. Record the maintenance work: Document the cable reference, connected baseplates, termination arrangement, and test results.

Compatible System Components

Component Function
Foxboro RH917JJ Provides the 0.5-meter base-to-base fieldbus connection
Foxboro P0917JJ Associated earlier cable reference
Foxboro P0940XA Baseplate Compatible baseplate type identified for the associated cable application
Foxboro P0940XB Baseplate Compatible baseplate type identified for the associated cable application
Foxboro RH916ND Shorter base-to-base fieldbus cable
Foxboro RH916MZ 1-meter base-to-base cable option
Foxboro RH916NC 3-meter base-to-base cable option
Foxboro RH916NB 5-meter base-to-base cable option
Foxboro RH916NA 10-meter base-to-base cable option
Foxboro RH916RB Terminator for applicable legacy fieldbus configurations

Recommended Related Models

Model Product Type Typical Application
Foxboro RH916ND 2 Mbps Base-to-Base Cable 0.25-meter connection between compatible baseplates
Foxboro RH916MZ 2 Mbps Base-to-Base Cable 1-meter communication connection
Foxboro RH916NC 2 Mbps Base-to-Base Cable 3-meter communication connection
Foxboro RH916NB 2 Mbps Base-to-Base Cable 5-meter communication connection
Foxboro RH916NA 2 Mbps Base-to-Base Cable 10-meter communication connection
Foxboro RH916RB Fieldbus Terminator Termination of applicable baseplate fieldbus connections

Key Advantages

  • Supports the designated 2 Mbps base-to-base communication link.
  • Provides a short cable option for closely positioned baseplates.
  • Supports compatible fieldbus arrangements, including redundancy where specified.
  • Allows replacement of the associated cable assembly while preserving the established system layout.

Technical FAQs

What is the relationship between RH917JJ and P0917JJ?

RH917JJ is associated with the earlier P0917JJ cable reference. Before replacement, verify the exact installed configuration and the cable requirements for the connected baseplates.

Which baseplates are associated with the RH917JJ cable?

The associated P0917JJ cable is listed for connections between compatible P0940XA or P0940XB baseplates. Confirm the actual baseplate model and fieldbus arrangement before installation.

Does the RH917JJ support redundant fieldbus connections?

The associated cable application supports bus redundancy in suitable configurations. Whether redundancy is required depends on the baseplate layout and system topology.

What should be checked if communication fails after cable replacement?

Inspect the connector seating, cable condition, baseplate compatibility, and termination arrangement. Also verify that the cable is connected to the intended fieldbus interfaces and that the configured communication topology is correct.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501