• Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card
  • Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card
  • Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card
  • Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card
Product Overview The Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 is a DeltaV M-Series RTD analog input assembly used to bring resistance-based temperature measurements from field sensors into the Delta……
Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card
  • Emerson
  • VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1
  • RTD Analog Input Card
  • USA
  • 107 × 41 × 105 mm
  • 0.5 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 DeltaV M-Series RTD Analog Input Card

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 is a DeltaV M-Series RTD analog input assembly used to bring resistance-based temperature measurements from field sensors into the DeltaV control environment. The combination includes the RTD analog input function together with associated M-Series termination hardware, forming a more complete field-to-I/O connection arrangement.

RTD sensors are commonly installed on process vessels, pipelines, heat exchangers, rotating equipment, and utility systems where continuous temperature measurement is required. The sensor produces a resistance change corresponding to the measured temperature, and the M-Series I/O architecture receives this field measurement for use by configured control strategies and monitoring functions.

The KJ3002X1-BF1 and KJ4001X1-CH1 components form part of the physical I/O and termination arrangement around the input card. This makes the assembly relevant to replacement and maintenance work where the existing DeltaV cabinet architecture needs to be retained rather than rebuilding the field interface from individual components.


Technical Specifications

Parameter Specification
Product Model VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1
Product Type RTD Analog Input Card Assembly
Product Family DeltaV M-Series
Manufacturer Emerson
System DeltaV
I/O Function RTD Analog Input
Input Signal Type RTD
Measurement Type Temperature Measurement
Measurement Principle Resistance-Based Temperature Measurement
Associated Hardware KJ3002X1-BF1 + KJ4001X1-CH1
Signal Direction Field Device to Control System
I/O Architecture Modular DeltaV M-Series I/O
System Integration DeltaV Controller and M-Series I/O Architecture
Dimensions 107 × 41 × 105 mm
Weight 0.5 kg

Product Features

  • RTD analog input assembly for the Emerson DeltaV M-Series control system.
  • Combines the VE4003S6B1 RTD input function with associated M-Series hardware.
  • Includes KJ3002X1-BF1 and KJ4001X1-CH1 components in the supplied assembly configuration.
  • Acquires resistance-based temperature measurements from field RTD sensors.
  • Provides a structured connection between field temperature instrumentation and the DeltaV I/O architecture.
  • Suitable for distributed temperature monitoring in process plants.
  • Supports temperature information used by configured DeltaV control, alarm, and monitoring functions.
  • Useful for maintenance and replacement work on established DeltaV M-Series installations.
  • Keeps the field termination and I/O arrangement aligned with the existing cabinet architecture.

Working Principle

The VE4003S6B1 assembly forms part of the complete RTD measurement path between a field temperature sensor and the DeltaV control system.

1. Temperature sensing

An RTD sensor changes its electrical resistance as its sensing element experiences a change in temperature. The resistance-based signal represents the process temperature at the measurement point.

2. Field wiring and termination

The RTD circuit travels through the field wiring toward the DeltaV cabinet. The associated M-Series termination hardware provides the physical interface required to connect the field circuit with the I/O arrangement.

3. RTD input acquisition

The VE4003S6B1 receives the RTD measurement through the M-Series I/O architecture. The KJ3002X1-BF1 and KJ4001X1-CH1 components form part of the associated connection and termination arrangement.

4. DeltaV processing

The acquired temperature information is passed into the DeltaV control environment. Configured control modules can use the measurement for process monitoring, alarming, trending, operator display, or temperature-related control functions.

RTD Sensor → Field Wiring → KJ3002X1-BF1 / KJ4001X1-CH1 → VE4003S6B1 → DeltaV Control Architecture

The complete measurement result depends on the condition and configuration of the sensor, field wiring, termination hardware, I/O card, and DeltaV input configuration.


Role in a DeltaV M-Series Temperature Measurement Control Architecture

The VE4003S6B1 assembly occupies the RTD measurement interface layer of the DeltaV M-Series architecture. Its associated termination components establish the field connection, while the analog input function brings the resistance-based temperature measurement into the control system.

System Layer Typical Component Function
Process Vessel / Pipeline / Heat Exchanger / Machine Provides the temperature condition being measured
Field Sensing RTD Sensor Detects temperature through resistance change
Field Interface KJ3002X1-BF1 / KJ4001X1-CH1 Provides the associated M-Series termination and connection arrangement
Analog I/O VE4003S6B1 Acquires RTD measurement signals
Control DeltaV Controller Processes temperature information within configured strategies
Operator Interface DeltaV Operator Station Displays temperature values, alarms, and process information

Industrial Applications

Application Assembly Role
Chemical Processing Interfaces RTD measurements from reactors, vessels, and process equipment with DeltaV
Oil and Gas Brings field temperature measurements into DeltaV process control
Power Generation Supports temperature monitoring of plant equipment and process systems
Pharmaceutical Manufacturing Acquires temperature measurements from process vessels and production equipment
Food and Beverage Processing Connects RTD-based temperature measurement with process automation
Petrochemical Processing Supports distributed temperature monitoring throughout process units
Utilities Interfaces temperature sensors used in plant utility and support systems
General Process Automation Provides an RTD measurement path within the DeltaV M-Series architecture

Installation and Maintenance

  1. Confirm that the complete VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 assembly matches the existing DeltaV M-Series I/O arrangement before installation.
  2. Isolate the applicable I/O section according to the plant’s approved electrical and process safety procedures.
  3. Verify the intended installation position and associated field termination connections before removing the existing assembly.
  4. Inspect the input card, termination components, and mating interfaces for contamination, corrosion, or mechanical damage.
  5. Confirm that the RTD field wiring corresponds to the intended input channel before reconnecting the assembly.
  6. Verify the RTD wiring arrangement and maintain the correct connection configuration during installation.
  7. Route the field measurement wiring to minimize mechanical stress and unnecessary exposure to electrical interference.
  8. Ensure the KJ3002X1-BF1 and KJ4001X1-CH1 connections are fully seated and mechanically secured as applicable to the installation.
  9. Verify the DeltaV input configuration and confirm that the selected channel corresponds to the installed RTD measurement.
  10. After energization, compare the displayed temperature with the expected process condition and investigate abnormal readings.
  11. If the temperature signal is unstable or incorrect, inspect the RTD sensor, field wiring, termination components, I/O card, and DeltaV configuration as one complete signal path.
  12. Record the assembly model, associated components, I/O position, field sensor, channel configuration, and maintenance observations for future service work.

Related Components

Component Function in the System
DeltaV M-Series Controller Executes configured process control strategies
KJ3002X1-BF1 Associated M-Series I/O/termination hardware within the assembly
KJ4001X1-CH1 Associated M-Series connection/termination component
RTD Sensor Measures temperature through changes in electrical resistance
RTD Field Wiring Carries the temperature measurement circuit between the field sensor and I/O system
DeltaV Operator Station Displays temperature values, alarms, and process information
Process Equipment Provides the temperature condition being measured
DeltaV Control Strategy Uses acquired temperature information for monitoring or process control

Recommended Related Models

Model Product Type Typical Relationship
Emerson VE4003S6 DeltaV M-Series RTD Analog Input Card Related RTD analog input hardware
Emerson VE4003S4B1 DeltaV M-Series Thermocouple/mV Analog Input Card Related DeltaV temperature input hardware
Emerson VE4003S5 DeltaV M-Series Thermocouple Analog Input Card Related M-Series temperature input hardware
Emerson VE4003S2B1 KJ3222X1-BA1 DeltaV M-Series Standard I/O Termination Block Related M-Series field termination hardware
Emerson VE4003S2B3 KJ3222X1-BA1 DeltaV M-Series 4-Wire I/O Termination Block Related M-Series termination hardware

Key Advantages

  • Combines RTD analog input functionality with associated DeltaV M-Series connection hardware.
  • Provides a structured field-to-I/O path for resistance-based temperature measurements.
  • Supports integration of RTD signals into DeltaV control and monitoring functions.
  • Suitable for established M-Series cabinets where the existing termination architecture must be retained.
  • Useful for maintenance, replacement, and refurbishment of DeltaV temperature measurement channels.
  • Supports distributed temperature monitoring across a range of process applications.

Technical FAQs

What does the VE4003S6B1 KJ3002X1-BF1+KJ4001X1-CH1 combination contain?

The supplied configuration combines the VE4003S6B1 RTD analog input function with KJ3002X1-BF1 and KJ4001X1-CH1 associated M-Series hardware. The combination should be treated as an integrated I/O and termination arrangement when checking replacement compatibility.

Why should the associated termination components be checked when replacing the assembly?

The termination components form part of the physical field connection between the RTD sensor and the DeltaV I/O architecture. Replacing only the input card without confirming the associated termination arrangement can result in connection or channel-matching problems.

What should be checked if an RTD channel reports an incorrect temperature?

The RTD sensor, field wiring, KJ3002X1-BF1 and KJ4001X1-CH1 connections, input card, and DeltaV channel configuration should all be inspected. Checking the complete signal path helps identify whether the problem originates in the field circuit, termination arrangement, I/O hardware, or configuration.

Is the VE4003S6B1 assembly a standalone temperature controller?

No. It is part of the DeltaV M-Series I/O architecture and provides the RTD measurement interface. The actual process control strategy is executed by the wider DeltaV control system using the acquired temperature information.