The ABB Bailey NKAS01-15 is an INFI 90 analog module termination cable used to establish the field wiring connection between an analog I/O termination arrangement and the associated INFI 90 control system hardware. It belongs to the ABB Bailey termination and interconnection hardware used around INFI 90 process control installations.
In an INFI 90 system, termination cables help move field wiring from the termination point to the corresponding I/O interface without requiring individual point-to-point connections directly at the control module. This makes the cable part of the physical signal path between field termination hardware and the system I/O interface.
The NKAS01-15 is intended for installations where the cable length and termination arrangement match the existing system configuration. It is particularly relevant for maintenance, replacement, and expansion work on established ABB Bailey INFI 90 systems where the original termination architecture needs to be preserved.
| Parameter | Specification |
|---|---|
| Product Type | Analog Module Termination Cable |
| Model | NKAS01-15 |
| Series | INFI 90 |
| Manufacturer | ABB Bailey |
| System | INFI 90 |
| Cable Function | Analog I/O Module Termination |
| Application | I/O Signal Interconnection |
| Cable Length | 15 feet |
| Shipping Weight | 3 kg |
The NKAS01-15 functions as a passive electrical interconnection within the INFI 90 I/O signal path. It does not independently process, condition, or control the analog signal. Instead, it provides the physical conductor path between the termination assembly and the associated analog module interface.
Field devices connect to the termination side of the I/O architecture. The termination arrangement organizes these field signals, while the NKAS01-15 carries the corresponding connections toward the analog I/O module.
Field devices → Termination assembly → NKAS01-15 → Analog I/O module → INFI 90 control system
For output applications, the signal direction is reversed: the control system sends the analog command through the I/O module and termination arrangement toward the field device. The cable therefore serves as part of the fixed signal interconnection rather than as an active signal-processing device.
The NKAS01-15 sits between the termination hardware and analog I/O interface in an ABB Bailey INFI 90 system. Its purpose is to maintain the physical connection between these system elements while keeping field termination separate from the electronic I/O module.
| System Layer | Typical Component | Function |
|---|---|---|
| Process Control | INFI 90 Controller | Executes process control logic and strategies |
| I/O Processing | INFI 90 Analog I/O Module | Handles analog field input or output signals |
| Interconnection | NKAS01-15 | Carries the analog I/O connections between termination and module |
| Termination | INFI 90 Termination Assembly | Provides organized field wiring termination |
| Field Interface | Transmitters / Valves / Instruments | Provides or receives process signals |
| Process | Industrial Equipment | Generates or responds to the controlled process variable |
| Application | Cable Role |
|---|---|
| Process Control Systems | Connects analog termination arrangements to INFI 90 I/O hardware |
| Chemical Plants | Supports organized analog field-signal interconnection |
| Power Generation | Maintains analog I/O wiring between field termination and control hardware |
| Oil and Gas Facilities | Provides structured signal routing within INFI 90 installations |
| Water Treatment | Supports analog instrumentation connections |
| Manufacturing Plants | Used in established Bailey INFI 90 automation cabinets |
| System Maintenance | Replaces damaged or aging termination cables without redesigning the I/O architecture |
| Component | Function in the System |
|---|---|
| ABB Bailey INFI 90 Analog I/O Module | Processes analog input or output signals |
| INFI 90 Termination Assembly | Provides the field wiring termination point |
| INFI 90 Controller | Executes process control functions |
| Field Transmitter | Supplies process measurement signals to the analog input system |
| Control Valve | Receives analog control signals from an analog output system |
| I/O Cabinet | Provides the physical installation environment for the termination and I/O hardware |
| Field Wiring | Connects process instruments and final control elements to the termination assembly |
| Model | Product Type | Typical Relationship |
|---|---|---|
| ABB Bailey NKAS01-15 | INFI 90 Analog Module Termination Cable | Same model and cable-length configuration |
| ABB Bailey NKAS01 Series | INFI 90 Analog Module Termination Cable | Related termination cable family |
| ABB Bailey NKCL01 Series | INFI 90 Termination Cable | Related INFI 90 cable family for system interconnection |
| ABB Bailey INFI 90 Analog I/O Modules | Analog I/O Module | Associated I/O hardware connected through termination architecture |
| ABB Bailey INFI 90 Termination Assemblies | I/O Termination Hardware | Mating termination hardware for field signal wiring |
The NKAS01-15 provides the electrical interconnection between an INFI 90 analog termination arrangement and the associated analog I/O module. It is a passive connection component rather than an active signal-processing module.
No. The NKAS01-15 is a termination cable. The actual analog signal processing is performed by the associated INFI 90 analog I/O hardware.
The existing INFI 90 termination arrangement, mating connectors, analog I/O module, cable routing, and cable length should be verified before replacement. Connector compatibility and correct channel wiring are particularly important.
The replacement should match the original system’s physical routing requirements and termination configuration. A different cable length should not be treated as an automatic substitute simply because the connectors appear similar.